BPMYZ - M60 S 1, OPEX ALUMINUM LACQUER

  • MSDS: BPMYZ
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: M60 S 1, OPEX ALUMINUM LACQUER
  • National Stock Number: 8010-00N032237
Product Identification

Product ID:M60 S 1, OPEX ALUMINUM LACQUER
MSDS Date:12/05/1986
FSC:8010
NIIN:00N032237
MSDS Number: BPMYZ

Responsible Party
SHERWIN-WILLIAMS CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

NAPHTHA, LIGHT ALIPHATIC (PETROLEUM); (LT. ALIPHATIC

CAS: 64742-89-8

Fraction By Weight: 45%


KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS).

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: <5%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


22.

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 15%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (LIGHT

CAS: 64742-95-6

RTECS: WF3400000

Fraction By Weight: <5%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


44.

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


0.6.

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: <5%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293


ADVERSE EFTS ON CNS/HEMATOPOIETIC

RTECS: 9999999ZZ


GLYCOL MONOBUTYL ETHER (EGBE) (EXTRACTED FROM DHHS

RTECS: 9999999ZZ


TRANSFER ONLY TO APPRVD CONTRS W/COMPLETE &

RTECS: 9999999ZZ


OF CHILDREN. THIS COATING CNTNS MATLS CLASSIFIED AS

RTECS: 9999999ZZ


CALCIUM CARBONATE, ETC. (SEE ACGIH TLV LIST,

RTECS: 9999999ZZ


ONLY DURING SANDING/ABRADING OF DRIED FILM.

RTECS: 9999999ZZ


CAN BE HARMFUL/FATAL. USE ONLY W/ADEQ VENT. AVOID

RTECS: 9999999ZZ


WASH HANDS AFTER USING. PROTECT AGAINST DUST WHICH

RTECS: 9999999ZZ


REFER TO OSHA STANDARDS 1910.94, 1910.107, 1910.108.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: OVEREXP CAUSES EYE/SKIN/RESP
IRRIT. MAY CAUSE NERVS SYS DEPRESS ACCOMPANIED BY
HDACH/DIZZ/NAUS/CONFUSION & STAG GAIT. EXTREME OVEREXP MAY RSLT IN
UNCON/POSSIBLY DEATH. CHRONIC: PRLNG OVEREXP TO INGREDS MAY CAUSE
ADVERSE EFTS TO LIVER/URINARY/BLOOD FORMING & CARDIO-VASCULAR
SYSTEMS. REPORTS HAVE (EFT OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ASSOC RPTD/PRLNG OVEREXPOS TO SOLV
W/PERM BRAIN & NERV SYS DMG. TOLUENE 108-88-3 APPEARS ON NAVY
LISTING OF OCCUP REPROD HAZ. SEEK CONSULTATION FROM APPROP HLTH
PROFESSIONALS CONCERNING LATE ST HAZ LIST INFO & SAFE HNDLG/EXPOS
RECOMMENDATIONS . ANIMAL STUDIES CLEARLY DEMONSTRATED DOSE-RELATED
(ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP & WATER.
REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES: FLUSH
WITH LARGE A MOUNTS OF WATER FOR A MINIMUM OF 15 MINUTES. GET
MEDICAL ATTENTION. INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON. DO NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF
WATER. SEEK MED ATTN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:25.0F,-3.9C
Lower Limits:0.7%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL (SUPP DATA)
Unusual Fire/Explosion Hazard:FLAMMABLE. FLASH BELOW 100F. KEEP CONTRS
TIGHTLY CLOSED. ISOLATE FROM HEAT/ELEC EQUIP/SPARKS/OPEN FLAME.
CLOSED CONTRS MAY EXPLODE WHEN EXPOSED TO (SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DOL STORAGE CATEGORY--1B. CONTENTS ARE
FLAMMABLE! KEEP AWAY FROM HEAT & OPEN FLAME. CONSULT NFPA CODE. USE
APPROVED BONDING & GROUNDING PROCEDURES.
Other Precautions:DURING USE & UNTIL ALL VAPORS ARE GONE: KEEP AREA
VENTILATED - DO NOT SMOKE - EXTINGUISH ALL FLAMES/PILOT
LIGHTS/HEATERS - TURN OFF STOVES/ELECTRIC TOOLS & APPLIANCES/ANY
OTHER SOURCES OF IGNIT. KEEP CONTR CLOSED WHEN NOT IN USE. (ING 9)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR RESPIRATORY DEVICE APPROVED
BY NIOSH/MSHA FOR PROTECTION AGAINST MATERIALS.
Ventilation:LOCAL EXHAUST PREFERABLE. GEN EXHAUST ACCEPTABLE IF
EXPOSURE TO MATLS IS MAINTAINED BELOW APPLIC EXPOS LIMITS. (ING 15)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING. LAUNDER CONTAMINATED
CLOTHING BEFORE RE-USE.
Supplemental Safety and Health
FIRE FIGHT PROC: CLOSED CONTRS TO PREVENT PRESS BUILD-UP & POSS
AUTOIGNIT/EXPLOS WHEN EXPOS TO EXTREME HEAT. EXPLO HAZ: EXTREME
HEAT. APPLICATION TO HOT SURF REQS SPECIAL PREC. DURING EMER CNDTNS
OVER EXP TO DECOMP PRODS MAY CAUSE HLTH HAZ.SYMP MAY NOT BE IMMED
APPARENT. OBTAIN MED ATTN.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:>172F,>78C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.83
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:88.9

Stability

Stability Indicator/Materials to Avoid:YES
CONTAM WITH H2O/ACIDS/ALKALIS CAN CAUSE EVOLUTION OF HYDROGEN, WHICH
MAY RSLT IN DANGEROUSLY INCR PRESS IN CLSD CONTRS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CO2, CO.

Disposal

Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM APPLIC
EPA HAZ WASTE#. INCIN IN APPRVD FACILITY. DO NOT INCIN CLOSED
CONTR. DISPOSE OF I/ A/ W FEDERAL, STATE, & LOCAL REGS REGARDING
POLLUTION

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.