BQDNL - LITHIUM BATTERY,BA-5590/U

  • MSDS: BQDNL
  • Manufacturer: POWER CONVERSION INC
  • Product Name: LITHIUM BATTERY,BA-5590/U
  • National Stock Number: 6135-01-036-3495
Product Identification

Product ID:LITHIUM BATTERY,BA-5590/U
MSDS Date:06/22/1992
FSC:6135
NIIN:01-036-3495
MSDS Number: BQDNL

Responsible Party
POWER CONVERSION INC
495 BOULEVARD
ELMWOOD PARK, NJ 07407-2029
US

Emergency Phone: 201-796-4800

Info Phone: 201-796-4800

Preparer: CARLOS VALENTIN

Cage: 5G978

Contractor
HAWKER ETERNACELL, INC.
ELMWOOD PARK, NJ 07407-2029 US

Telephone: 201-796-6243

Cage: 5G978

Ingredients

LITHIUM

CAS: 7439-93-2

RTECS: OJ5540000


SULFUR DIOXIDE (SARA III)

CAS: 7446-09-5

RTECS: WS4550000

OSHA PEL 5 PPM/5 STEL

ACGIH TLV: 2 PPM/5 STEL; 9293


ACETONITRILE (SARA III)

CAS: 75-05-8

RTECS: AL7700000

OSHA PEL 40 PPM/60 PPM STEL

ACGIH TLV: 40 PPM/67 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:CONTACT WITH ELECTROLYTE CAN CAUSE SEVERE
IRRITATION TO EYES,SKIN,MUCOUS MEMBRANES.BREATHING VAPOR FROM
VENTING CELL MAY CAUSE PULMONARY EDEMA.EXTENDED EXPOSURE TO HIGH
CONCENTRATIONS IN CONFINED SPAC E CAN LEAD TO ASPHYXIATION.
Medical Cond Aggravated by Exposure:NOT KNOWN

First Aid

First Aid:ANY SKIN,EYE OR MUCOUS MEMBRANE CONTACT WITH ELECTROLYTE
SHOULD BE FOLLOWED BY FLUSHING WITH LARGE QUANTITIES OF WATER. IN
CAES OF EYE CONTACT,FLUSH WITH WATER FOR AT LEAST 15
MINUTES,CONSULT A PHYSIC IAN. INHALATION:EMPLOYEE BREATHING VAPORS
FROM VENTING CELL SHOULD BE REMOVED TO FRESH AIR.

Fire Fighting

Flash Point:NOT KNOWN
Lower Limits:NOT KNOWN
Upper Limits:NOT KNOWN
Extinguishing Media:USE SAND,DRY CHEMICAL,FOAM,MET-L-X.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
& FULL TURNOUT GEAR .REMOVE OTHER BATTERIES & POTENTIAL COMBUST
MATLS FROM AREA OF BURNING BATTERY(SEE SUP)
Unusual Fire/Explosion Hazard:HEATING CELL >160F OR SHORT CIRCUITING
CELL CAN LEAD TO VENTING & RELEASE OF SO2 & ACETONITRILE.>354F LEAD
TO MELTING OF LITHIUM & REPRESENTS SEVERE HAZARD.

Accidental Release

Spill Release Procedures:IF CELL VENTS OR IS PUNCTURED,VENTILATE AREA
WELL.WASH AWAY ANY LIQUID RESIDUE WITH WATER.WEAR EYE AND HAND
PROTECTION. RESPIRATOR MAY BE NECESSARY IN CONFINED SPACES.
Neutralizing Agent:NOT KNOWN

Handling

Handling and Storage Precautions:DO NOT PUNCTURE,INCINERATE,SHORT
CIRCUIT OR EXPOSE TO TEMP >160F.STORE IN ORIGINAL CONTAINERS.NEVER
STORE IN LOOSE BINS.
Other Precautions:DO NOT USE CELLS IN HERMETICALLY SEALED CONTAINERS.DO
NOT EXPOSE CELLS TO CHARGING CURRENTS.NEVER CUT INTO CELL.

Exposure Controls

Respiratory Protection:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE
TO DETERMINE IF RESPIRATORY PROTECTION IS REQUIRED .
Ventilation:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE TO DETERMINE
IF LOCAL EXHAUST VENTILATION IS NEEDED .
Protective Gloves:NOT KNOWN
Eye Protection:WEAR EYE PROT WHEN HANDLING BATTERIES.
Other Protective Equipment:NOT KNOWN
Work Hygienic Practices:NOT KNOWN
Supplemental Safety and Health
OUTSIDE PACKAGE DIMENSIONS (INCHES):4 1/2 X 2 5/8 X 5 1/8.WEIGHT
(LB):2.25.FIRE FIGHT PROC:AND CONTAIN AND EXTINGUISH WITH
EXTINGUISHING AGENTS.WASTE DISP METH:OF IN SANITARY LANDFILLS.

Chemical Properties

HCC:Z6
Boiling Pt:B.P. Text:NOT KNOWN
Melt/Freeze Pt:M.P/F.P Text:NOT KNOWN
Decomp Temp:Decomp Text:NOT KNOWN
Vapor Pres:NOT KNOWN
Vapor Density:NOT KNOWN
Spec Gravity:NOT KNOWN
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NOT KNOWN
Appearance and Odor:NOT KNOWN

Stability

Stability Indicator/Materials to Avoid:YES
DO NOT EXPOSE VENTED CELLS TO WATER.
Stability Condition to Avoid:AVOID EXPOSURE TO TEMPERATURES ABOVE 160F.
Hazardous Decomposition Products:ACETONITRILE MAY DECOMPOSE ABOVE 245F,
RELEASING HIGHLY TOXIC CYANIDES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISP MUST BE IAW W/ FEDERAL,STATE,AND LOCAL
REGS. COORDINATE WITH SUPPORT INSTALL &/OR MACOM ENVIRON OFC PRIOR
TO DISP .DISCHARGED CELLS MAY CONTAIN SIGNIFICANT AMTS OF
ENERGY.HANDLE W/ CARE. E LEC ISOLATED & PACKED.DO NOT
COMPACT.DISPOSE(SEE S

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.