Product Identification
Product ID:"CRONALITH" LIQUID BLENDER REPLENISHER-PART
MSDS Date:06/01/1986
FSC:6750
NIIN:01-026-0158
MSDS Number: BQKRD
Responsible Party
WILMINGTON, DE 19899
US
Emergency Phone: 800-441-3637 800-421-9300 CHEMTREC
Info Phone: 800-346-4748
Cage: 18873
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
TRIETHYLENE GLYCOL
CAS: 112-27-6
RTECS: YE4550000
Fraction By Weight: <40%
HYDROQUINONE (SARA III)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: <20%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SODIUM FORMALDEHYDE BISULFITE
Fraction By Weight: <20%
Hazards
LD50 LC50 Mixture:LD50 (ORAL RAT) 320 MG/KG (HYDROQUINONE)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT IS AN AQUEOUS SOLUTION OF
SEVERAL COMPONENTS. IT MAY CAUSE EYE AND SKIN IRRITATION.
INHALATION OF MIST OR DRIED RESIDUE MAY CAUSE RESPIRATORY
IRRITATION. INGESTION MAY CAUSE GASTROINTESTI NAL IRRITATION.
Explanation of Carcinogenicity:MANUFACTURER STATES "NONE OF THE
COMPONENTS IN THIS CHEMICAL IS LISTED BY IARC,NTP, OR OSHA AS A
CARCINOGEN.
Effects of Overexposure:EYE IRRITATION, RESPIRATORY IRRITATION,
DERMATITIS, COUGHING, NAUSEA, HEADACHE, SKIN IRRITATION.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE LIVER, OR BONE MARROW MAY HAVE INCREASED
SUSCEPTIBILITY TO THE TOXIC EFFECTS.
First Aid
First Aid:EYE CONTACT: IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR
AT LEAST 15 MINUTES. CALL A PHYSICIAN. SKIN CONTACT: IMMEDIATELY
WASH SKIN WITH SOAP AND WATER. INHALATION: REMOVE VICTIM TO FRESH
AIR. CAL L A PHYSICIAN. INGESTION: DO NOT INDUCEVOMITING. GIVE
LARGE QUANTITIES OF WATER IF VICTIM IS CONSCIOUS. CALL A PHYSICIAN
IMMEDIATELY.
Fire Fighting
Flash Point:NONE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. KEEP PERSONNEL
REMOVED AND UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:DIKE SPILL. PREVENT LIQUID FROM ENTERING
SEWERS, WATERWAYS OR LOW AREAS. SOAK UP WITH SAWDUST, SAND, OIL DRY
OR OTHER ABSORBENT MATERIAL. USE APPROPRIATE PERSONAL PROTECTIVE
EQUIPMENT DURING CLEAN UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS TIGHTLY CLOSED WHEN
NOT IN USE AND AWAY FROM ACIDS. STORE IN WELL VENTILATED AREA.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:USE ONLY WITH ADEQUATE VENTILATION.
Protective Gloves:LATEX OR NEOPRENE
Eye Protection:SPLASH GOGGLES
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
INDUSTRIAL-TYPE WORK CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
TECHNICAL CHARACTERISTICS STATE "CRONALITH LIQUID BLENDER REPLISHER
PART MUST BE MIXED WITH PART B TO OBTAIN WORKING SOLUTION. DU PONT
ADVISED 14 APR 1993 THIS ITEM IS OBSOLETE
Chemical Properties
HCC:T6
Spec Gravity:1.1-1.2
pH:5-6
Solubility in Water:COMPLETE
Appearance and Odor:LIGHT AMBER TO TAN, CLEAR LIQUID WITH NONE TO MILD
FISHY ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:PHOTOPROCESSING EFFLUENTS: DISCHARGE TO SEWER
REQUIRES APPROVAL OF PERMITTING AUTHORITY AND MAY REQUIRE
PRETREATMENT. REMOVE NONUSEABLE SOLID MATERIAL AND/OR CONTAMINATED
SOIL, FOR DISPOSAL IN AN APPR OVED AND PERMITTED LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.