BQLKY - SIL-X GREASE NLGI 1, CPS255779
- MSDS: BQLKY
- Manufacturer: CHEVRON
- Product Name: SIL-X GREASE NLGI 1, CPS255779
- National Stock Number: 9150-00N035881
Product Identification
Product ID:SIL-X GREASE NLGI 1, CPS255779
MSDS Date:12/19/1990
FSC:9150
NIIN:00N035881
MSDS Number: BQLKY
Responsible Party
US
Emergency Phone: 800-457-2022;800-424-9300(CHEMTREC)
Info Phone: 800-582-3825
Cage: 0AHD1
Contractor
Telephone: 800-582-3835
Cage: 0AHD1
Ingredients
NEAREST MED EMER TRTMT CTR/HOSP. NOTE TO PHYS
RTECS: 9999999ZZ
W/ACCIDENTS INVOLVING HIGH-PRESS EQUIP. WHEN EJECTED
RTECS: 9999999ZZ
& LEAVE SM, SOMETIMES BLOODLESS, PUNCTURE WOUND.
RTECS: 9999999ZZ
A FINGERTIP CAN BE DEPOSITED INTO PALM OF HAND. W/IN
RTECS: 9999999ZZ
DISCOLORATION, & INTENSE THROBBING PAIN IN AFFECTED
RTECS: 9999999ZZ
CHEVRON SIL-X GREASE NLGI 1
Fraction By Weight: 100%
RESIDUAL OILS SOLVENT REFINED
Fraction By Weight: <95%
SILICA, AMORPHOUS FUMED
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: 6%
ADDITIVES
Fraction By Weight: <2%
PROD CNTNS PETROLEUM BASE OILS WHICH MAY BE
RTECS: 9999999ZZ
SEV HYDROCRACKING/SEV HYDROTREATING. NONE OF OILS REQ
RTECS: 9999999ZZ
(29CFR1910.1200). PROD CNTNS A TYPE OF AMORPHOUS
RTECS: 9999999ZZ
COUGH, BRONCHIAL IRRIT, CHEST
RTECS: 9999999ZZ
DUST HAS CAUSED IMPAIRED PULM FUNC & MORPHOLOGICAL
RTECS: 9999999ZZ
RATS & GUINEA PIGS WERE UNAFFECTED BY AMORPHOUS
RTECS: 9999999ZZ
TO RESP PREC OUTLINED IN THIS DOCUMENT IS
RTECS: 9999999ZZ
PERS BEFORE INDUCE VOMIT. IF MED ADVICE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: SUBSTANCE IS NOT EXPECTED
TO CAUSE PRLNGD/SIGNIFICANT IRRIT. HAZ EVALUATION IS BASED ON DATA
FROM SIMILAR MATLS. SKIN: SUBSTANCE IS NOT EXPECTED TO CAUSE
PRLNGD/SIGNIFICANT IRRIT. HAZ EVAL UATION IS BASED ON DATA FROM
SIMILAR MATLS. INGEST: SYSTEMIC TOX OF SUBSTANCE HAS NOT BEEN
DETERMINED. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HOWEVER, IT SHOULD BE PRACTICALLY
NON-TOX TO INTERNAL ORGANS IF IT GETS ON SKIN. HIGH-PRESS EQUIP
INFO: ACCIDENTAL HIGH-VELOCITY INJECTION UNDER SKIN MATLS OF THIS
TYPE MAY RSLT IN SERIOUS IN JURY. INHAL: SYSTEMIC TOX OF THIS
SUBSTANCE HAS NOT BEEN DETERMINED. HOWEVER, IT SHOULD BE
PRACTICALLY (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:NO FIRST AID PROC ARE REQD. HOWEVER, AS A PREC FLUSH
W/FRESH WATER FOR @ LST 15 MIN. REMOVE CONT LENSES IF WORN. SKIN:
NO FIRST AID PROC ARE REQD. AS A PREC, WASH THORO W/SOAP/WATER.
REMOVE & WASH CONTAMD CLTHG. INHAL: NO FIRST AID PROC ARE REQD.
REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF RESP) . INGEST:
GIVE WATER/MILK TO DRINK & TELEPHONE FOR MED ADVICE. CONSULT MED
(ING 12)
Fire Fighting
Flash Point:482F,250C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. READ
ENTIRE DOCUMENT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:THIS MATERIAL IS NOT EXPECTED TO PRESENT ANY
ENVIRONMENTAL PROBLEM. CLEAN UP SPILLS IMMEDIATELY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT WELD, HEAT/DRILL CONTR. RESIDUE
MAY IGNITE W/EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY. CAUTION: DO
NOT USE PRESS TO EMPTY DRUM/EXPLO MAY RSLT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NO SPECIAL RESP PROT IS NORMALLY REQD. HOWEVER,
IF OPERATING CONDITIONS CREATE HIGH AIRBORNE CONCENTRATIONS, USE OF
AN NIOSH/MSHA APPROVED RESPIRATOR IS RECOMMENDED.
Ventilation:USE ADEQ VENT TO KEEP AIRBORNE CONC OF THIS MATL BELOW
RECOMM EXPOSURE STANDARD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SKIN CONTACT CAN BE MINIMIZED BY WEARING
PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: NON-TOX TO INTERNAL ORGANS IF INHALED. HAZ EVALUATION
IS BASED ON DATA FROM SIMILAR MATLS. INGEST: SYSTEMIC TOX OF THIS
SUBSTANCE HAS NOT BEEN DETERMINED. HOWEVER, IT SHOULD BE PRACTI
CALLY NON-TOX TO INTERNAL ORGANS IF SWALLOWED. HAZ EVALUATION
EVALUATION IS BASED ON DATA FROM SIMILAR MATLS. (ING 5)
Chemical Properties
HCC:V7
Boiling Pt:B.P. Text:>637F,>336C
Spec Gravity:<[email protected]
Solubility in Water:INSOLUBLE
Appearance and Odor:RED TRANSLUCENT GREASE; PETROLEUM HYDROCARBON ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
MAY REACT WITH STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,
PEROXIDES, ETC.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NORMAL COMBUSTION FORMS CARBON DIOXIDE
AND WATER VAPOR; INCOMPLETE COMBUSTION CAN PRODUCE CARBON MONOXIDE.
Disposal
Waste Disposal Methods:PLACE CONTAMINATED MATLS IN DISPOSABLE CONTRS &
DISPOSE OF IN A MANNER CONSISTENT W/APPLIC REGS. CONT LOCAL, STATE
& FEDERAL ENVIRONMENTAL OR HLTH AUTHORITIES FOR APPROVED DISPOSAL
OF THIS MATERIAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.