BQRFV - MOLYBDATE REAGENT, 5190

  • MSDS: BQRFV
  • Manufacturer: RICCA CHEMICAL CO
  • Product Name: MOLYBDATE REAGENT, 5190
  • National Stock Number: 6810-00N036645
Product Identification

Product ID:MOLYBDATE REAGENT, 5190
MSDS Date:02/19/1990
FSC:6810
NIIN:00N036645
MSDS Number: BQRFV

Responsible Party
RICCA CHEMICAL CO
ARLINGTON, TX 76013
US

Emergency Phone: 817-461-5601

Info Phone: 817-461-5601

Cage: RICCA

Contractor
RICCA CHEMICAL CO.
13090 ARLINGTON, TX 76013 US

Telephone: 817-461-5601

Cage: RICCA

Ingredients

2140

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: SEE ING

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MOLYBDIC ACID, DISODIUM SALT DIHYDRATE; (SODIUM MOLYDBATE).

CAS: 10102-40-6

RTECS: QA5085000

Fraction By Weight: SEE ING

OSHA PEL 5 MG/M3 (MO)

ACGIH TLV: 5 MG/M3 (MO)


950 ML/L

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: SEE ING

Hazards

LD50 LC50 Mixture:(ING 1)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALTHOUGH CORROSIVE EFTS OF
OVEREXPOSURE TO THIS SOLUTION SHOULD BE LESS SEVERE THAN HIGHER
CONCENTATIONS OF SULFURIC ACID. TARGET ORGANS INCLUDE:RESPIRATORY
SYSTEM, EYES, SKIN, TEETH.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRITATION OF EYES, NOSE, THROAT;
PULMONARY EDEMA, DENTAL EROSION, BURNS OF SKIN, EYES.
Medical Cond Aggravated by Exposure:CHRONIC RESPIRATORY DISEASE.
PRE-EXISTING EYE PROBLEMS. PRE-EXISTING SKIN DISORDERS.

First Aid

First Aid:IN ALL CASES SEEK QUALIFIED EVALUATION. EYE:IRRIGATE IMMED
WITH LARGE QTYS OF RUNNING WATER. SKIN:WATER FLUSH IMMEDIATELY.
REMOVE ANY CONTAMINATED CLOTHING. INHALATION:REMOVE TO FRESH AIR.
GIVE ARTIFI CIAL RESPIRATION IF NECESSARY. INGEST:DILUTE
IMMEDIATELY WITH WATER OR MILK. DO NOT INDUCE VOMITING. GET MEDICAL
HELP.

Fire Fighting

Extinguishing Media:USE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .

Accidental Release

Spill Release Procedures:COVER THE CONTAMINATED AREA WITH SODIUM
BICARBONATE OR SODA ASH-SLAKED LIME MIXTURE (50-50). MIX AND ADD
WATER IF NECESSARY TO FORM SLURRY. SCOOP UP SLURRY AND WASH DOWN
DRAIN WITH EXCESS WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM IMCOMPATIBLE
MATERIALS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NORMAL ROOM VENTILATION IS ADEQUATE. WEAR
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:NORMAL ROOM VENTILATION IS ADEQUATE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES. ADD (SUP DATA)
Other Protective Equipment:LAB COAT OR LAB APRON.
Work Hygienic Practices:WASH HANDS AFTER HANDLING THIS OR ANY OTHER
CHEMICAL BEFORE EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER. EYE PROTECTION: FULL LENGTH FACESHIELD
TO GOGGLES .

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32F, 0C
Spec Gravity:1.01
Solubility in Water:INFINITE
Appearance and Odor:CLEAR, COLORLESS, ODORLESS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
BASES, METALS, METAL OXIDES, STRONG REDUCING OR OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:ADD SLOWLY TO AGITATED SOLUTION OF SODA ASH AND
SLAKED LIME. FLUSH NEUTRALIZED SOLUTION TO DRAIN WITH EXCESS OF
WATER. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.