BQSWX - ULTRAJET
- MSDS: BQSWX
- Manufacturer: CHEMTRONICS INC
- Product Name: ULTRAJET
- National Stock Number: 6830-00-495-8614
Product Identification
Product ID:ULTRAJET
MSDS Date:01/01/1991
FSC:6830
NIIN:00-495-8614
MSDS Number: BQSWX
Responsible Party
HAUPPAUGE, NY 11788
US
Emergency Phone: 516-582-3322
Info Phone: 516-582-3322
Preparer: M. WATKINS
Cage: 2M589
Contractor
Telephone: 315-736-2206
Cage: 0CKD9
Ingredients
CHLORODIFLUOROMETHANE
CAS: 75-45-6
RTECS: PA6390000
Fraction By Weight: 100%
OSHA PEL 1000 PPM
ACGIH TLV: 1000PPM; 9192
Hazards
LD50 LC50 Mixture:LC50 RAT = 300,000 PPM / 2 HR.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-VAPOR IS HEAVIER THAN AIR &
CAN CAUSE SUFFOCATION BY REDUCING OXYGEN AVAILABLE FOR BREATHING.
EYE-LIQUID CONTACT CAN CAUSE FROSTBITE. ORAL-ALTHOUGH ORAL TOXICITY
IS LOW, INGESTION OF ULTRAJ ET IS TO BE AVOIDED. SKIN-LIQUID
CONTACT CAN CAUSE FROSTBITE.
Explanation of Carcinogenicity:THIS PRODUCT IS NOT LISTED BY NTP, IARC,
OR OSHA.
Effects of Overexposure:INHALATION-BREATHING HIGH CONCENTRATIONS OF
VAPOR CAN CAUSE LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF BREATH,
POSSIBLE NARCOSIS, POSSIBLE CARDIAC IRREGULARITIESS,
UNCONSCIOUSNESS, DEATH. SKIN-IRRITATI ON OR REDDENING MAY OCCUR.
INGESTION-MAY CAUSE NAUSEA & VOMITING, WITH IRRITATION TO MOUTH &
GI TRACT. EYE-DISCOMFORT.
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE. SEE HEALTH
HAZARDS, INHALATION SECTION.
First Aid
First Aid:INHALE-REMOVE TO FRESH AIR & CALL PHYSICIAN. IF NOT
BREATHING, PERFORM CPR, PREFERRABLE MOUTH-TO-MOUTH. IF BREATHING IS
HARD, GIVE OXYGEN. DO NOT GIVE EPINEPHRINE/SIMILAR DRUGS.
SKIN-FLUSH WITH WATER. INGESTION-NO SPECIFIC INTERVENTION IS
INDICATED AS THE COMPOUND IS NOT LIKELY TO BE HAZARDOUS, HOWEVER,
DO NOT INDUCE VOMITING. EYE-IMMEDIATELY FLUSH WITH WATER FOR 15
MIN. SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TOC
Flash Point:NONE
Lower Limits:NONFLAMMABLE
Upper Limits:NONFLAMMABLE
Extinguishing Media:NONFLAMMABLE
Fire Fighting Procedures:OTHER BURNING MATERIAL MAY CAUSE ULTRAJET TO
BURN WEAKLY. SCBA MAY BE REQUIRED IF CYLINDERS RUPTURE OR CONTENTS
ARE RELEASED UNDER FIRE CONDITIONS.
Unusual Fire/Explosion Hazard:PRESSURIZED AEROSOL CONTAINERS MAY VENT,
RUPTURE OR EXPLODE & ADD TO FLYING & FALLING DEBRIS. DECOMPOSITION
CAN OCCUR.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE OPEN FLAMES OR OTHER
SOURCES OF IGNITION. COLLECT SPILLED PRODUCT WITH ABSORBENT
MATERIAL AND PLACE IN CLOSED STEEL DRUMS FOR PROPER DISPOSAL.
Handling
Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT, IN
DIRECT SUNLIGHT OR WHERE TEMPERATURES EXCEED 120F. ROTATE STOCK.
Other Precautions:NOTE TO PHYSICIAN: BECAUSE OF POSSIBLE INCREASED RISK
OF ELICITING CARDIAC DYSRYTHMIAS, CATECHOLINAMINE DRUGS, SUCH AS
EPINEPHRINE, SHOULD BE USED ONLY AS A LAST RESORT IN LIFE
THREATENING EMERGENCIES .
Exposure Controls
Respiratory Protection:NO. GOOD VENTILATION/H.C. RESPIRATOR.
Ventilation:NO. AS NEEDED TO COMPLY WITH TLV.
Protective Gloves:YES. BUTYL GLOVES.
Eye Protection:YES. CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NORMAL VENTILATION FOR STANDARD PROCEDURES.
LOCAL EXHAUST FOR WHEN LARGE AMOUNTS ARE RELEASED. MECHANICAL FOR
LOW PLACES
Supplemental Safety and Health
CONTAINS CHEMICALS LISTED ON THE TSCA INVENTORY LIST: YES.
Chemical Properties
HCC:G3
Boiling Pt:B.P. Text:-41F,-41C
Vapor Pres:138 PSIG
Vapor Density:2.98
Spec Gravity:1.19
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:0.30% BY WT
Appearance and Odor:LIQUIFIED GAS, CLEAR, COLORLESS, SLIGHT ETHERAL
ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWERED AL (ALUMINUM), ZN (ZINC), BE
(BERYLLIUM) OR MG (MAGNESIUM).
Stability Condition to Avoid:AVOID SPRAYING NEAR OPEN FLAMES OR RED HOT
SURFACES. DO NOT HEAT AEROSOL CONTAINERS ABOVE 120F/49C.
Hazardous Decomposition Products:THIS PRODUCT CAN BE DECOMPOSE BY HIGH
TEMPERATURES FORMING HYDROCHLORIC & HYDROFLUORIC ACIDS & POSSIBLE
CARBONYL HALIDES
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS. DO NOT PUNCTURE OR INCINERATE AEROSOL CANS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.