BQVGZ - CT-6002

  • MSDS: BQVGZ
  • Manufacturer: CHEM TREND INC
  • Product Name: CT-6002
  • National Stock Number: 6850-00N037898
Product Identification

Product ID:CT-6002
MSDS Date:03/21/1986
FSC:6850
NIIN:00N037898
MSDS Number: BQVGZ

Responsible Party
CHEM-TREND INC
3205 EAST GRAND RIVER
HOWELL, MI 48843
US

Emergency Phone: 517-546-4520

Info Phone: 517-546-4520

Cage: 2W738

Contractor
CHEM-TREND INC
860 HOWELL, MI 48844-0860 US

Telephone: 800-727-7730

Cage: 2W738

Ingredients

HYDROCARBON SOLVENT; (HYDROCARBON NAPHTHA)

Fraction By Weight: 80-90%

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


WAX DISPERSION; (WAX BLEND)

Fraction By Weight: 10-20%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN: PRLNGD/RPTD CONT MAY
DEFAT SKIN WHICH MAY CAUSE IRRIT/DERM. AVOID SKIN CONT. EYE: LIQ
PROD SPLASHED IN EYE WILL PROBABLY IRRITATE. INHAL: VAP CONC ABOVE
TLV MAY CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH, &
EVEN ASPHY (@ EXTREME LEVELS). INGEST: IF PROD IS ACCIDENTALLY
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:SWALLOWED, VOMIT SHOULD NOT BE INDUCED
BECAUSE OF DANGER OF ASPIR OF SOLV INTO LUNGS, WHICH CAN BE FATAL
DUE TO CHEM PNEUM. CHRONIC: THERE IS MINIMAL EVIDENCE FOR SERIOUS
EFTS OF CHRONIC EXPO S (TO SOLV) FOR HUMANS, ACCDG AMERICAN
CONFERENCE OF GOVERNMENTAL INDUST HYGIENISTS. (DOCUMENTATION FOR
"STODDARD SOLV")
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: WASH WITH SOAP AND WATER. LAUNDER CONTACTED CLOTHING
BEFORE REUSE. EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES.
CONTACT PHYSICIAN. INHAL: MOVE TO FRESH AIR. CONTACT PHYSICIAN.
INGEST: DO NOT I NDUCE VOMITING. CONTACT PHYSICIAN IMMEDIATELY.

Fire Fighting

Flash Point Method:PMCC
Flash Point:103F,39C
Lower Limits:1%
Upper Limits:6%
Extinguishing Media:USE FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:SMALL SPILLS: SOAK UP W/ABSORB MATL. LARGE
SPILLS: ELIM ALL SOURCES OF IGNIT. VAPORS ARE HEAVIER THAN AIR &
MAY SPREAD LONG DISTANCES OR COLLECT IN LOW SPOTS. DIKE AREA TO
PREVENT RUNOFF, RECOVER LIQU ID, SOAK UP REMAINING LIQ W/ABSORBENT
MATL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT CUT, PUNCTURE OR WELD ON EMPTY
DRUM BECAUSE IT MAY CONTAIN EXPLOSIVE OR HARMFUL VAPORS. KEEP AWAY
FROM HEAT, SPARKS & FLAMES.
Other Precautions:STORE AWAY FROM STRONG OXIDIZERS. GROUND ALL EQUIP
PUMPING PROD. PROTECT FROM STATIC ELECTRICAL SPARKS/OTHER IGNITION
SOURCES. DO NOT STORE AT TEMPERATURES ABOVE 110F TO AVOID VAP PRESS
IN CLSD CONTRS . KEEP CONTRS CLSD WHEN NOT IN USE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD RESP MAY BE USED WHEN
ENGINEERING & WORK PRACTICES CTLS ARE NOT TECHNICALLY FEASIBLE,
WHEN SUCH CTLS ARE IN PROCESS OF BEING INSTALLED/WHEN THEY FAIL &
NEED TO BE SUPPLEMENTED. IF US E OF A RESP IS NEC, USE ONLY (SUPP
DATA)
Ventilation:GOOD INDUST HYGIENE PRACT RECOM THAT ENGINEERING CTLS (SUCH
AS LOC &/OR MECH VENT) BE USED TO REDUCE (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES (SUCH AS (SUPP DATA)
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APPROPRIATE CLOTHING TO AVOID SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
BP:310F, 154C (INITIAL). VP: <12 (NAPHTHA). % VOLAT: 80-90(WT). RESP
PROT: A NIOSH/MSHA APPRVD AIR SUPPLIED RESP/AN AIR-PURIFYING RESP.
VENT: ENVIRONMENTAL CONC TO PERMISSIBLE EXPOS LEVELS. PROT GLOVE S:
NEOPRENE, POLYVINYL ALCOHOL, NBR NITRILE).

Chemical Properties

Boiling Pt:B.P. Text:SUPP DATA
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:0.78
Evaporation Rate & Reference:<1(ETHER=1)
Solubility in Water:NIL
Appearance and Odor:OFF-WHITE FLUID; NAPHTHA ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STORE AWAY FROM STRONG OXIDIZERS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:HYDROCARBON DECOMPOSITION PRODUCTS AT
ELEVATED TEMPERATURES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.