BQXHQ - CYCLE II, 5291

  • MSDS: BQXHQ
  • Manufacturer: MANTEK DIV OF NCH CORP
  • Product Name: CYCLE II, 5291
  • National Stock Number: 7930-00N038276
Product Identification

Product ID:CYCLE II, 5291
MSDS Date:10/18/1990
FSC:7930
NIIN:00N038276
MSDS Number: BQXHQ

Responsible Party
MANTEK DIV OF NCH CORP
IRVING, TX 75015
US

Emergency Phone: 214-438-1381

Info Phone: 214-438-1381

Preparer: RICHARD STOLLEY

Cage: GO368

Contractor
NCH CORP
152170 IRVING, TX 75015-2170 US

Telephone: 972-438-0563

Cage: 20913

Ingredients

ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

OSHA PEL 1000PPM;1250PPM STEL

ACGIH TLV: 1000PPM;1250PPM STEL


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY IRRIT EYES,SKIN &
THROAT.RAPID EVAP OF LIQ FROM SKIN CAN CAUSE FROSTBITE.INHAL OF
EXTREM HIGH CONCS OF VAPS CAN CAUSE DIZZ,LOW BLOOD PRESS,HEAT
ARRTHYMIA & ASPHYXIA.DEGREE OF EXPOS UNLIKELY
W/AEROSOL.CHRONIC:RPTD OVEREXP CAN SENSIT HEART TO EPINEHPRINE
WHICH MAY CAUSE HEART TO STOP SUDDENLY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:UPON PHYS EXERTION.DEGREE OF EXPOS IS
UNLIKELY W/AEROSOL. CHLOROFLUOROCARBON (CFC) MATLS HAVE PRDCED
SENSIT OF MYOCARDIUM TO EPHINEPHRINE IN LAB ANIMALS & COULD HAVE
SIMILAR EFT IN HUMANS. AD RENOMIMETICS (E.G., EPINEPHRINE) MAY
BECONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY/ (SUPP DATA)
Medical Cond Aggravated by Exposure:MEDICAL CONDITIONS WHICH ARE
AGGRAVATED BY PROLONGED OVEREXPOSURE TO THIS PRODUCT ARE
RESPIRATORY AND CARDIAC, DUE TO THE ANESTHETIC NATURE OF THE
PRODUCT.

First Aid

First Aid:INHAL:REMOVE PATIENT TO FRESH AIR. GIVE MOUTH-TO-MOUTH
RESUSCITATION IF BRTHG HAS STOPPED.GIVE OXYGEN AS NEC.DO NOT GIVE
ADRENALIN (EPINEPHRINE). CALL PHYS.EYE: FLUSH W/LRG AMTS OF WATER
LIFTING EYELI DS OCCAS FOR AT LST 15 MINS.IF EYE SYMPS PERSIST,
CONSULT PHYS. SKIN:WASH W/WATER. APPLY EMOLLIENT-RICH CREAM IF
DRYNESS PERSISTS. INGEST: DO NOT INDUCE VOMIT. GIVE 2 GLASSES OF
WATER & SEEK MED ATTN.

Fire Fighting

Flash Point Method:CC
Flash Point:NON-FLAMMABLE
Extinguishing Media:FOAM, "ALCOHOL" FOAM, CARBON DIOXIDE, DRY CHEMICAL,
WATER SPRAY.
Fire Fighting Procedures:PROD IS NONFLAM. WEAR NIOSH/MSHA APPRVD PRESS
DEMAND SCBA & FULL PROT EQUIP. CHOICE OF ABOVE MEDIA DEPENDS ON
NATURE OF FIRE. COOL EXPOS CNTNRS (SUPDAT)
Unusual Fire/Explosion Hazard:UNDER SPECIAL CONDITIONS OF HEAT,
HYDROCHLORIC AND HYDROFLUORIC ACID CAN BE FORMED.THERM DECOMP
PRODUCTS MAY INCLUDE CHLORIDES, FLUORIDES AND PHOSGENE .

Accidental Release

Spill Release Procedures:AEROSOL PACKAGING, SO SPILL HIGHLY UNLIKELY.
VENT AREA & PICK UP WITH ABSORBENT. PLACE INTO LABELED CONTAINERS
FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT MODERATE TEMPERATURES. 120F
MAX-32F MIN.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.CONTENTS UNDER
PRESS.FOLLOW LBL DIRECTIONS.NO SMOKING IN AREA OF USE.DO NOT USE IN
GEN VICINITY OF ARC WELDING,OPEN FLAMES/HOT SURFS.HEAT &/OR UV
RADIA MAY CAUSE FORM OF CHLORIDES,FLUORIDES AND PHOSGENE .

Exposure Controls

Respiratory Protection:4,500 PPM NIOSH/MSHA APPROVED SA/SCBA-THESE
RESPIRATORS MAY BE USED IN CASE OF AN ESCAPE GMOV/SCBA EMERGENCY
SITUATION. PLEASE NOTE THAT USE OF ABOVE IS NOT LIKELY.
Ventilation:GOOD INDUS HYGIENE PRACT DICTATES THAT WORK AREA SHOULD BE
ISOLATED & CONTAINED & PROVIDED W/ADEQ LOC EXHST (SUPP DATA)
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT APPLICABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROCEDURES: WITH WATER TO PREVENT FROM RUPTURING. EFFECTS OF
OVEREXPOSURE: CHRONICALLY EXPOSED TO CFC'S . VENTILATION:
VENTILATION OR OTHER CONTROLS TO MAINTAIN THE AIR CONCENTRATIONS
OF THIS PRODUCT BELOW 1000 PPM AS REQUIRED BY OSHA.

Chemical Properties

Boiling Pt:B.P. Text:112F,45C
Vapor Pres:334
Vapor Density:2.9
Spec Gravity:1.57 (H*2O=1)
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:NON-VISCOUS, WATER-WHITE, TRANSPARENT, ETHEREAL
ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
REACTIVE METALS. MAY REACT VIOLENTLY WITH SODIUM, POTASSIUM AND BARIUM
PARTICULARLY IF FINELY DIVIDED.
Stability Condition to Avoid:NAKED FLAMES AND HOT SURFACES.
Hazardous Decomposition Products:HYDROGEN FLUORIDE, HYDROGEN CHLORIDE
AND TRACES OF CARBONYL HALIDE (PHOSGENE). CHLORIDES, FLUORIDES .

Disposal

Waste Disposal Methods:DO NOT PUNCTURE OF INCINERATE AEROSOL CONTAINER.
WRAP IN SEVERAL LAYERS OF NEWSPAPER AND DISPOSE OF EMPTY CAN IN
TRASH. CHECK WITH ALL FEDERAL, STATE AND LOCAL POLLUTION CONTROL
AUTHORITIES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.