Product Identification

Product ID:KONTACT APTT REAGENT (500 DETERMINATIONS),(
MSDS Date:08/10/1992
FSC:6550
NIIN:00N038522
MSDS Number: BRFBQ

Responsible Party
PACIFIC HEMOSTASIS
2493 PORTOLA RD
VENTURA, CA 93003
US

Emergency Phone: 805-644-0848

Info Phone: 805-644-0848

Cage: FO220

Contractor
PACIFIC HEMOSTASIS
HIALEAH, FL 33010-2427 US

Telephone: 305-885-0131

Cage: FO220

Ingredients

SODIUM AZIDE

CAS: 26628-22-8

RTECS: VY8050000

OSHA PEL 0.3 MG/M3, C

ACGIH TLV: 0.29 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: CAN CAUSE SKIN
IRRITATION. NEUROLOGICAL EFFECTS IF INHALED AT EXTREMELY HIGH
LEVELS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:INHALATION: HEADACHE, DIZZINESS, BLURRED
VISION, LOWERED BLOOD PRESSURE, SLOW PULSE & RESPIRATORY TRACT
IRRITATION. SKIN: IRRITATION IF IT COMES INTO PROLONGED CONTACT
WITH MOIST SKIN.
Medical Cond Aggravated by Exposure:NONE IDENTIFIED.

First Aid

First Aid:INGEST: INDUCE VOMTIING BY GIVING WATER AND P-AMINO
PROPIOPHENONE. INHAL: REMOVE FROM EXPOSURE, APPLY ARTIFICIAL
RESPIRATION IF NECESSARY. SKIN/EYE: FLUSH WITH WATER FOR AT LEAST
15 MIN. CONTACT PHYSI CIAN IN INSTANCES OF ALL OF THE ABOVE.

Fire Fighting

Extinguishing Media:USE DRY CHEMICAL OR SODA ASH. DO NOT USE WATER.
SODIUM METAL CAN REACT WITH WATER TO FORM HYDROGEN.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WHEN HEATED TO DECOMPOSITION THIS COMPOUND
EMITS TOXIC FUMES.
Unusual Fire/Explosion Hazard:EXPLOSION HAZARD BY HEAT OR SHOCK.
EXPLOSIVE METAL AZIDES FORM WITH COPPER OR LEAD.

Accidental Release

Spill Release Procedures:RECOVER SPILT THROMBOSCREEN CACL*2, SOLUTION
OR ABSORB ON AN INERT MATERIAL AND PLACE IN A NON-METAL CONTAINER.
RINSE AREA WITH WATER. WEAR PROTECTIVE EQUIPMENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:SODIUM AZIDE CAN REACT WITH COPPER AND
LEAD PLUMBING, SODIUM HYDROXIDE CAN BE USED AS A CLEANING AGENT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:LABORATORY-GRADE LATEX.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: 0224006 10-0315-GEN. BOILING PT: 662F, 350C
(DECOMPOSES).

Chemical Properties

Boiling Pt:B.P. Text:SUPP DATA
Vapor Pres:NEGLIGIBLE
Vapor Density:2.2
Spec Gravity:1.85
Solubility in Water:42%
Appearance and Odor:WHITE GRANULAR POWDER IN A RAW FORM; ODORLESS.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:NO
HYDRAZOIC ACID, PB, AG, HG, CU, CS*2, BR*2, HNO*3, BENZYL CHLORIDE AND
KOH.
Stability Condition to Avoid:HEAT OR SHOCK.
Hazardous Decomposition Products:SODIUM AZIDE DECOMPOSES TO SODIUM
METAL & CAN EMIT HYDRAZOIC ACID, WHICH IS A HIGHLY TOXIC FUME, AT
TEMP AT & >350C.

Disposal

Waste Disposal Methods:SML QTYS OF RECONSTITUTION FLUID MAY BE POURED
INTO A DRAIN OR SEWER & FLUSHED W/LRG QTYS OF WATER. DISPOSE OF
I/A/W ALL LOCAL, STATE & FEDERAL REGS. ALL OF ABOVE PERTAINS TO
CACL*2 SOLN ONLY WHICH CN TNS SODIUM AZIDE AS A PRESERVATIVE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.