BRHRB - TECHNETIUM TC-99M GENERATOR (FISSION)

Product Identification

Product ID:TECHNETIUM TC-99M GENERATOR (FISSION)
MSDS Date:11/02/1992
FSC:6505
NIIN:00N038931
MSDS Number: BRHRB

Responsible Party
E I DU PONT DE NEMOURS & CO INC
331 TREBLE COVE RD
NORTH BILLERICA, MA 01862
US

Emergency Phone: 800-483-7616;800-424-9300(CHEMTREC)

Info Phone: 617-482-9595;800-225-1572

Cage: 51851

Contractor
E I DU PONT DE NEMOURS & CO INC
NORTH BILLERICA, MA 01862 US

Telephone: 617-482-9595;800-225-1572

Cage: 51851

Ingredients

MANAGEMENT PROCEDURES FOR RADIOACTIVE MATERIAL SPILLS

RTECS: 9999999ZZ


FEDERAL RADIOLOGICAL RESPONSE TEAM.

RTECS: 9999999ZZ


SODIUM PERTECHNETATE TC-99M (TC-99M DAUGHTER OF MO-99)

CAS: 13718-28-0

Fraction By Weight: <<0.1%


OF LIQ LEAKAGE RESULTING FROM DMG IN TRANSIT IS

RTECS: 9999999ZZ


TO REMOVE CONTAINER UNLESS AUTHORIZED TO DO SO.

RTECS: 9999999ZZ


LIFE-SAVING MISSIONS. LIMIT AREA ENTRY TIME. SPILLS

RTECS: 9999999ZZ


ABSORBENT MATL. FOR LRG SPILLS DETAIN UNINJURED

RTECS: 9999999ZZ


MATERIAL UNTIL OBTAINING DIRECTION OF QUALIFIED

RTECS: 9999999ZZ

Fraction By Weight: ING

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IONIZING RADIATION: EXPOSURE TO
IONIZING RADIATION IS REGULATED UNDER 29 CFR 1910.96 AND 10 CFR 20.
ACGIH ACCEPTS THE RECOMMENDATIONS OF THE NATIONAL COUNCIL ON
RADIATION PROTECTION & MEASUREMENTS (NC RP) FOR IONIZING RADIATION
TLV & STRONGLY RECOMMENDS THAT ALL EXPOSURE TO IONIZING RADIATION
BE KEPT (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:AS LOW AS REASONABLY ACHIEVABLE
(ALARA). TOX:THE TOX OF SODIUM PERTECHNETATE TC-99MM HAS NOT BEEN
FULLY QUANTIFIED. ALLERGIC RXNS INCL ANAPHYLAXIS HAVE BEEN REPORTED
INFREQUENTLY FOLLOWING CL INICAL ADMINISTRATION OF SODIUM
PERTECHNETATE TC-99M. INDIVIDUALS HNDLG OR (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:REMOVE FROM EXPOSURE AREA TO FRESH AIR IMMED. OBTAIN &
PROVIDE EMERGENCY MED ASSISTANCE AS REQUIRED & NOTIFY MD & HLTH
PHYSICIST IMMED. INHAL:MOVE TO FRESH AIR IMMED. SKIN:REMOVE CONTAM
CLTHG & RINSE AFFECTED AREAS W/LARGE AMTS OF WATER. WASH W/SOAP &
MILD DETERGENT. EYE:WASH EYES IMMED W/LRG AMTS OF WATER FOR @ LST
15 MIN. INGEST: TREAT SYMPTOMATICALLY & SUPPORTIVELY. IF VOMIT
OCCURS PVNT ASPIR.

Fire Fighting

Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR FOAM.
Fire Fighting Procedures:DO NOT MOVE DAMAGED CNTNRS. MOVE UNDAMAGED
CNTNRS OUT OF FIRE ZONE IF POSSIBLE. AVOID BRTHG DUSTS/VAPORS FROM
FIRE, KEEP UPWIND. CONTACT LOC, STATE OR (ING 8)
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO
HEAT OR FLAME. DOT HAZARD CLASS: RADIOACTIVE MATERIAL.

Accidental Release

Spill Release Procedures:DO NOT TOUCH DMGD CNTNRS UNTIL ASSISTANCE FROM
QUALIFIED PERSONNEL IS OBTAINED. DMG TO OUTER CNTNR MAY NOT AFFECT
PRIMARY INNER CNTNR OF PACKAGING. BECAUSE THE GENERATOR IS WELL
CNTND & ESSENTIALLY DR Y, THERE IS LITTLE LIKELIHOOD OF CONTAM(SUPP
DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:AVOID INHALATION OF VAPORS OR CONTACT WITH EYES.

Exposure Controls

Respiratory Protection:NONE REQUIRED FOR NORMAL CLINICAL USE. WHERE
OPERATING PARAMETERS, QUANTITY OF MATERIAL, AND CONDITIONS OF USE
REQUIRED, PROPER USE OF NIOSH/MSHA APPROVED RESPIRATORY PROTECTION
IS RECOMMENDED.
Ventilation:LOC EXHST RECOMM FOR ANY OPERATIONS PRESENTING A RISK OF
AIRBORNE CONTAM THRU EVAP, FLAKING, DUSTING/AEROSOL FORMATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING APPROPRIATE TO PREVENT
SKIN CONTACT.
Work Hygienic Practices:MONITOR PERSONAL RADIATION DOSE EXPOSURE AS
APPROPRIATE & MAINTAIN PROPER VENT CONTROL OVER WORK AREAS.
Supplemental Safety and Health
EFTS OF OVEREXP: ADMINISTERING SODIUM PERTECHNETATE TC-99M SHOULD
CONSULT THE PACKAGE INSERT FOR ADDITIONAL INFORMATION REGARDING
CLINICAL USE OF THIS PRODUCT. PREGNANT WOMEN AND NURSING MOTHERS
MAY B E AT INCREASED RISK FROM RADIATION EXPOSURE. SPILL PROC: DUE
TO DAMAGE IN TRANSIT. THE MOST PROBABLE SOURCE (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
pH:4.5-7
Solubility in Water:SOLUBLE
Appearance and Odor:STERILE, NON PYROGENIC, AQUEOUS RADIOACTIVE ELUTED
SOLUTION.

Stability

Stability Indicator/Materials to Avoid:YES
NO DATA AVAILABLE
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
TOXIC AND/OR HAZARDOUS GASES.

Disposal

Waste Disposal Methods:OBSERVE LOCAL, STATE AND FEDERAL REGULATIONS
REGARDING STORAGE AND DISPOSAL OF MATERIALS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.