BRLCQ - EXTERIOR GRADE STUCCO, 1209
- MSDS: BRLCQ
- Manufacturer: QUIKRETE COMPANIES
- Product Name: EXTERIOR GRADE STUCCO, 1209
- National Stock Number: 5610-00N039410
Product Identification
Product ID:EXTERIOR GRADE STUCCO, 1209
MSDS Date:04/01/1990
FSC:5610
NIIN:00N039410
MSDS Number: BRLCQ
Responsible Party
ATLANTA, GA 30345
US
Emergency Phone: 404-634-9100
Info Phone: 404-297-8324
Cage: IO174
Contractor
Telephone: 404-634-9100
Cage: IO174
Ingredients
TRICALCIUM SILICATE
CAS: 12168-85-3
OSHA PEL N/K
ACGIH TLV: N/K
DICALCIUM SILICATE
CAS: 10034-77-2
OSHA PEL N/K
ACGIH TLV: N/K
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
TRICALCIUM ALUMINATE
CAS: 12042-78-3
OSHA PEL N/K
ACGIH TLV: N/K
TETRACALCIUM ALUMINOFERRATE
CAS: 12068-35-8
OSHA PEL N/K
ACGIH TLV: N/K
CALCIUM CARBONATE; (MARBLE), (LIMESTONE)
CAS: 1317-65-3
RTECS: EV9580000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
UNIDENTIFIED COMPONENT
CAS: 13997-24-5
OSHA PEL N/K
ACGIH TLV: N/K
CALCIUM HYDROXIDE; (HYDRATED LIME) (MFR CAS# 39445-23-3)
CAS: 1305-62-0
RTECS: EW2800000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 5 MG/M3; 9293
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:CAN DRY SKIN AND CAUSE ALKALI
BURNS. DUST CAN IRRITATE THE EYES AND UPPER RESPIRATORY SYSTEM.
TOXIC EFFECTS NOTED IN ANIMALS INCLUDE, FOR ACUTE EXPOSURES,
ALVEOLAR DAMAGE WITH PULMONARY EDEMA. C HRONIC:DUST CAN CAUSE
INFLAMMATION OF THE LINING TISSUE OF THE INTERIOR OF THE NOSE AND
INFLAMMATION (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OF THE CORNEA. HYPERSENSITIVE
INDIVIDUALS MAY DEVELOP AN ALLERGIC DERMATITIS. EXCESSIVE
INHALATION OF SILICA DUST MAY RESULT IN RESPIRATORY DISEASE,
INCLUDING SILICOSIS, PNEUMONONIOSIS, PULMO NARY FIBEROSIS AND
POSSIBLY CANCER. SYMPS OF EXCESS EXPOS INCLUDING SHORTNESS OF
BREATH & REDUCED PULMONARY FUNCTION.
Medical Cond Aggravated by Exposure:INDIVUDIALS WITH SENSITIVE SKIN
WITH PULMONARY AND/OR RESPIRATORY DISEASE, INCLUDING, BUT NOT
LMITED TO, ASTHMA & BRONCHITIS, OR SUBJECT TO EYE IRRITATION,
SHOULD BE PRECLUDED FROM EXPOSURE.
First Aid
First Aid:EYE:IRRIGATE (FLOOD) IMMEDIATELY AND REPEATEDLY WITH CLEAN
WATER FOR AT LEAST 15 MINUTES. SKIN:WASH EXPOSED AREA WITH SOAP &
WATER. APPLY STERILE DRESSINGS. INHAL:REMOVE PERSON IMMEDIATELY TO
FRESH AI R, GIVE ARTIFICIAL RESPIRATION AS NEEDED. GET MD.
Fire Fighting
Flash Point:NON COMBUSTIBLE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:USE DUSTLESS METHODS (VACUUM) AND PLACE INTO
CLOSABLE CONTAINER FOR DISPOSAL OR USED IF NOT CONTAMINATED OR WET.
USE ADEQUATE VENTILATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:PRECAUTIONS MUST BE OBSERVED BECAUSE BURNS OCCUR WITH
LITTLE WARNING--LITTLE HEAT IS SENSED.
Exposure Controls
Respiratory Protection:IN DUST ENVIRONMENTS, THE USE OF A NIOSH/MSHA
APRPOVED RESPIRATOR IS RECOMMENDED.
Ventilation:LOCAL EXHAUST CAN BE USED, IN NECESSARY, TO CONTROL
AIRBORNE DUST LEVELS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:BARRIER CREAMS, BOOTS & CLOTHING TO PROTECT
SKIN FROM CONTACT. EMERGENCY EYE WASH AND DELUGE SHOWER.
Work Hygienic Practices:FOLLOWING WORK, WORKERS SHOULD SHOWER WITH SOAP
& WATER.
Supplemental Safety and Health
MATLS TO AVOID:OXIDIZING AGENTS SUCH AS FLUORINE, CHLORINE TRIFLUORIDE,
MANGANESE TRIOXIDE AND OXYGEN DIFLUORIDE MAY CAUSE FIRES.
Chemical Properties
Solubility in Water:SLIGHT
Appearance and Odor:GRAY COLORED WITH NO ODOR
Stability
Stability Indicator/Materials to Avoid:YES
SILICA WILL DISSOLVE IN HYDROFLUORIC ACID & PRODUCE A CORROSIVE
GAS--SILICON TETRAFLUORIDE. CNTCT W/POWERFUL (SUPDAT)
Stability Condition to Avoid:KEEP DRY UNTIL USED TO PRESERVE PRODUCT
UTILITY.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:CAN BE TREATED AS A COMMON WASTE FORE DISPOSAL
IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.