BRPKJ - 65873 - TEFLON SPRAY TAPE

  • MSDS: BRPKJ
  • Manufacturer: KAR PRODUCTS INC
  • Product Name: 65873 - TEFLON SPRAY TAPE
  • National Stock Number: 8030-00N012492
Product Identification

Product ID:65873 - TEFLON SPRAY TAPE
MSDS Date:10/01/1986
FSC:8030
NIIN:00N012492
MSDS Number: BRPKJ

Responsible Party
KAR PRODUCTS INC
461 NORTH 3RD AVENUE
DES PLAINES, IL 60016-1160
US

Emergency Phone: 708-296-6111

Info Phone: 708-296-6111

Cage: 5L381

Contractor
KAR PRODUCTS
DES PLAINES, IL 60016 US

Telephone: 847-296-6111

Cage: 5L381

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 60%

OSHA PEL 350 PPM;450 PPM STEL

ACGIH TLV: 350 PPM;450 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 16-17%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAIN ING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE/CHRONIC: MAY CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DIZZINESS OR NARCOSIS IN HIGH VAPOR
CONCENTRATIONS. WILL CAUSE DEFATTING OF SKIN. EFFECTS ARE
REVERSIBLE. LONG TERM EXPOSURE (YEARS) TO VAPOR MAY CAUSE LUNG,
LIVER OR KIDNEY DAMAGE. SIGNS & S YMPTOMS MAY INCLUDE DIFFICULTY IN
BREATHING, REDNESS OR IRRITATION OF SKIN & VOMITING.
Medical Cond Aggravated by Exposure:HEART DISEASE.

First Aid

First Aid:INHAL:REMOVE PERSON TO FRESH AIR & GIVE OXYGEN. SKIN:WASH
W/SOAP & WATER. EYES:FLUSH W/LARGE QUANTITIES OF WATER FOR AT LEAST
15 MINS. INGEST:GASTRIC LAVAGE. DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:TCC
Flash Point:-40F,-40C
Lower Limits:1.8%
Upper Limits:12%
Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT . KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE . HEATED CANS MAY BURST ABOVE 130F.

Accidental Release

Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
MATERIAL. PUT INTO CONTAINER. DISPOSE OF AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT TEMPERATURES BELOW 120F. KEEP
AWAY FROM HEAT, SPARKS OR OPEN FLAME. DO NOT SMOKE WHILE SPRAYING.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY
CAUSE FORMATION OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SCBA IF TLV LIMITS IS BEING
EXCEEDED.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES . NONE (SUP DAT)
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:LONG SLEEVES & LONG PANTS.
Work Hygienic Practices:WASH HANDS AFTER USE.
Supplemental Safety and Health
VP:45 PSIG @ 70F. PROT GLOVES:REQUIRED IF SPRAYING.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:>-40F,>-40C
Vapor Pres:SUPP DATA
Vapor Density:4 HVR/AIR
Spec Gravity:1.3 (H*2O=1)
Evaporation Rate & Reference:4.6 (BUTYL ACETATE=1)
Solubility in Water:NONE
Appearance and Odor:BLUE; SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:HCL . IF FIRE FORMS PHOSGENE &
HYDROCHLORIC ACID.

Disposal

Waste Disposal Methods:DISPOSE OF AS HAZARDOUS WASTE IN ACCORDANCE
W/EPA RCRA. DISPOSAL MUST BE IN ACCORDANCE W/FEDERAL, STATE & LOCAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.