BRSKD - NITROGEN

  • MSDS: BRSKD
  • Manufacturer: SCOTT MARRIN INC
  • Product Name: NITROGEN
  • National Stock Number: 6830-00N043677
Product Identification

Product ID:NITROGEN
MSDS Date:12/20/1990
FSC:6830
NIIN:00N043677
MSDS Number: BRSKD

Responsible Party
SCOTT-MARRIN INC
2001 THIRD ST UNIT II
RIVERSIDE, CA 92507
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 714-784-1240

Cage: GO386

Contractor
SCOTT-MARRIN, INC
RIVERSIDE, CA 92507 US

Telephone: 714-653-6780

Cage: 55995

Ingredients

SUITABLE HAND TRUCK. FOR ADDNL HNDLG PREC CONSULT

RTECS: 9999999ZZ


"NONFLAM GAS" LABEL & SHIPPING CLASSIFICATION OF

RTECS: 9999999ZZ


GASES IN ALUMINUM CYLINDERS.

RTECS: 9999999ZZ


NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


CYLS WHEN IN USE. KEEP CYL AWAY FROM HEAT,

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NITROGEN MAY PRODUCE SUFFOCATION BY
DILUTING THE CONCENTRATION OF OXYGEN IN AIR NECESSARY TO SUPPORT
LIFE. OXYGEN CONCENTRATION <19.5% MUST BE AVOIDED. OXYGEN DEFICIENT
ATMOSPHERES MAY PRODUCE DIZZINE SS, NAUSEA, VOMITING, LOSS OF
CONSCIOUSNESS & DEATH. DEATH MAY RESULT FROM ERRORS IN JUDGEMENT,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONFUSION OR LOSS OF CONSCIOUSNESS
WHICH PREVENTS SELF-RESCUE. AT LOW OXYGEN CONCENTRATIONS,
UNCONSCIOUSNESS & DEATH CAN OCCUR IN SECONDS WITHOUT WARNING.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/POTABLE WATER FOR
AT LEAST 15 MIN, SEEK ASSISTANCE FROM MD . SKIN: FLUSH W/COPIOUS
AMOUNTS OF WATER. CALL MD . INHAL:REMOVE PERSON TO UNCONT AMINATED
AREA. SELF-CONTAINED BREATHINGAPPARATUS MAY BE REQUIRED TO PREVENT
ASPHYXIATION OF RESCUE WORKERS IN LOW OXYGEN ATMOSPHERES. IF
BREATHING HAS STOPPED, START ARTF RESP & ADMIN PURE OXYGEN.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .

Accidental Release

Spill Release Procedures:VENTILATE ENCLOSED AREAS TO PREVENT OXYGEN
DEFICIENT ATMOSPHERES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE CYLS IN DRY, COOL WELL VENT
AREA. AVOID HEAT, FLAME/SPARKS. DO NOT STORE IN HEAVILY TRAVELLED
AREAS. SEGREGATE FULL & EMPTY CYLS. AVOID (SUPDAT)
Other Precautions:SHIPMENT OF COMPRESSED GAS CYLS FILLED W/OUT
PERMISSION OF OWNER IS VIOLATION OF FED LAW. IF OXYGEN DEFICIENT
ATMS ARE SUSPECTED/ CAN OCCUR, USE OXYGEN MONITORING EQUIP. GAS
CYLS MEET ALL APPLIC DOT S PECIFICATIONS. DOT REGS REQ (ING 4)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS IS REQUIRED IN OXYGEN DEFICIENT ATMOSPHERES.
CAUTION:RESPIRATORS WILL NOT FUNCTION.
Ventilation:NATURAL OR MECHANICAL. VENTS SHOULD BE SITUATED TO PREVENT
LOW OXYGEN LEVELS IN WORK AREA.
Protective Gloves:LEATHER GLOVES.
Eye Protection:CHEMICAL SAFETY GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:0.97 @ 70F & 1ATM(AIR=1). VAP DENS:0.725 LB/CU FT @ 70F &
1ATM. HNDLG/STOR PREC:STOR WHERE SALT/CORR CHEMS ARE PRESENT. VALVE
CAPS ON ALL CYLS NOT CONNECTED FOR USE. GAS IS IN CYL @ HIGH PRE
SS. USE ONLY W/HIGH PRESS EQUIP. USE A PRESS REDUCING REGULATOR
WHEN CONNECTING TO LOW PRESS PIPING SYS. SECURE (ING 2)

Chemical Properties

HCC:G3
Vapor Pres:2000 PSI
Vapor Density:SUPDAT
Spec Gravity:SUPDAT
Appearance and Odor:COLORLESS AND ODORLESS GAS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FED, STATE &
LOCAL REGULATIONS . VENT NITROGEN GAS SLOWLY TO A WELL VENTILATED
OUTDOOR LOCATION. RETURN CYLINDERS TO MANUFACTURER W/RESIDUAL
PRESSURE, CLYLIND ER VALVE CLOSED & VALVE PROTECTIVE CAP INSTALLED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.