BSTLL - WASP & HORNET SPRAY, 75679

Product Identification

Product ID:WASP & HORNET SPRAY, 75679
MSDS Date:04/09/1990
FSC:6840
NIIN:00N047670
MSDS Number: BSTLL

Responsible Party
KAR PRODUCTS INC./DISTRIBUTOR
461 NORTH THIRD AVENUE
DES PLAINES, IL 60016
US

Emergency Phone: 312-296-6111

Info Phone: 312-296-6111

Cage: 5L381

Contractor
KAR PRODUCTS
DES PLAINES, IL 60016 US

Telephone: 847-296-6111

Cage: 5L381

Ingredients

PYRETHRUM; (PYRETHRINS)

CAS: 8003-34-7

RTECS: UR4200000

Fraction By Weight: 0.077%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TOLUENE,

CAS: 51-03-6

RTECS: XS5805000

Fraction By Weight: 0.193%

OSHA PEL N/K

ACGIH TLV: N/K


KEROSENE (PETROLEUM), HYDROTREATED; (PETROLEUM DISTILLATE).

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 25%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


CARBAMIC ACID, METHYL, 1-NAPHTHYL ESTER; (CARBARYL)

CAS: 63-25-2

RTECS: FC5950000

Fraction By Weight: 0.515%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


7.5%

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 55%

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHANE, DICHLORO-; (METHYLENE CHLORIDE)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 15%

OSHA PEL 500 PPM,C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: <5%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM;30000 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:REPORTS HAVE ASSOCIATED RPTD & PRLNGD
OVEREXP TO SOLV W/PERM BRAIN & NERV SYS DAM. ALSO KIDNEY & LIVER
DAM. PURSUANT TO PROPOSITION 65: CERTAIN RAW MATLS USED IN MAKING
PROD MAY CNTN SM AMTS OF MATLS AS IMPURITIES WHICH ARE REGULATED
BY PROPOSITION 65. IN A CONFINED AREA VAPS IN HIGH CONC ARE ANESTH.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONOGRAPHS
SUPPLEMENT, VOL 7, PG 194, 1987: GRP 2B. NTP 6TH ANNUAL REPORT ON
CARCIN, (SUPDAT)
Effects of Overexposure:HLTH HAZ: IRRITANT TO SKIN & UPPER RESP SYS.
OVEREXP MAY RSLT IN LT-HEAD, STAGGER GAIT, GIDD, & POSS NAUS. CNTNS
PETROLEUM DISTILLATES-HARMFUL/FATAL IF SWALLOWED. CHLOROCARBON
MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (SUPP
DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMED FLUSH W/WATER FOR AT LEAST 15 MINUTES. GET IMMED
MED ATTN. SKIN: PROMPTLY WASH CONTAMD SKIN W/SOAP & WATER. IF CLTHG
PENETRATED, REMOVE & WASH SKIN W/SOAP & WATER. GET PROMPT MED ATTN.
INH AL: MOVE TO FRESH AIR & PERFORM ARTF RESP IF BRTHG HAS STOPPED.
KEEP WARM & QUIET. GET MED ATTN. ASAP. INGEST: CALL PHYS IMMED. DO
NOT INDUCE VOMIT.

Fire Fighting

Flash Point:170F,77C
Lower Limits:SEE INGRED
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL/FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESS DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . WATER MAY BE INEFTIVE. WATER MAY BE
USED TO KEEP FIRE EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:DO NOT SPRAY NEAR OPEN FLAME. KEEP @
ROOM TEMP AS EXPOS TO DIRECT SUNLIGHT/OTHER HEAT MAY CAUSE
BURSTING. THERMAL DECOMP PROD MAY INCL HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE,
AVOID BREATHING VAPORS, AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. KEEP AT ROOM
TEMPERATURE AS EXPOSURE TO DIRECT SUNLIGHT OR HEAT MAY CAUSE
BURSTING.
Other Precautions:KEEP AWAY FROM CHILDREN. DO NOT PUNCT/INCIN. DO NOT
SPRAY NEAR FIRE/OPEN FLAME. NO SMOKING IN AREA OF USE. DO NOT USE
IN GEN VICIN OF ARC WELD, OPEN FLAMES/HOT SURF. HEAT &/OR UV RADIA
MAY CAUSE FORM OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:AVOID BREATHING OF VAPOR/SPRAY MIST. USE
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:LOC EXHST: PROVIDE LOC EXHST VENT IN VOL & PATTERN TO KEEP
TLV OF ALL HAZ INGRED BELOW ACCEPTABLE &/OR STATED LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:FACE SHIELD OR GOGGLES.
Other Protective Equipment:WEAR APPROP EQUIP/CLTHG (APRON) TO PVNT
RPTD/PRLNGD SKIN CONT. EMPLOYEES SHOULD WASH PROMPTLY WHEN SKIN
BECOMES(SUPDAT)
Work Hygienic Practices:FOLLOW CAUTIONS ON PRODUCT LABEL, USE
REASONABLE CARE AND PRACTICE GOOD HABITS OF CLEANLINESS.
Supplemental Safety and Health
EXPLAN OF CARCIN:1991: ANTIC TO BE CARCIN. ANIMAL: BLADDER CANCER,
LIVER, SKIN EFTS. EFTS OF OVEREXP: (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR CH RONICALLY EXPOS TO CHLOROCARBONS . OTHER PROT EQUIP: WET.
PROMPTLY REMOVE NON-IMPERVIOUS CLTHG THAT BECOME WET.

Chemical Properties

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER(ETHER=1)
Appearance and Odor:CLEAR/PRUDENT
Percent Volatiles by Volume:99

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:BY OPEN FLAME: CARBON MONOXIDE, CARBON
DIOXIDE, HYDROGEN CHLORIDE, AND PHOSGENE GAS.

Disposal

Waste Disposal Methods:DO NOT INCINERATE-DISPOSE I/A/W LOCAL, STATE AND
FEDERAL REGULATIONS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.