BTCJF - PUMICE
- MSDS: BTCJF
- Manufacturer: KERR
- Product Name: PUMICE
- National Stock Number: 6505-00-550-6650
Product Identification
Product ID:PUMICE
MSDS Date:05/06/1993
FSC:6505
NIIN:00-550-6650
MSDS Number: BTCJF
Responsible Party
ROMULUS, MI 48174-0908
US
Emergency Phone: 313-946-7800
Info Phone: 313-946-7800
Cage: GO270
Contractor
Telephone: 800-537-7187
Cage: 33339
Ingredients
SILICA DIOXIDE, CRYSTALLINE QUARTZ, SAND (SUSPECTED HUMAN
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: 2-6%
ACGIH TLV: 0.1 MG/CUM RESP DUST
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE CHRONIC LUNG
INJURY (SILICOSIS), CAN BE PROGRESSIVE & MAY LEAD TO DEATH. SKIN:
DRY FEELING. EYES: TEMPORARY IRRITATION & INFLAMMATION.
Explanation of Carcinogenicity:NONE
First Aid
First Aid:EYES: FLUSH W/COPIOUS AMOUNTS OF WATER. SKIN: WASH W/SOAP &
WATER. USE HAND LOTION. INHALATION: MOVE EXPOSED PERSON TO FRESH
AIR. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Accidental Release
Spill Release Procedures:VACUUM/SWEEP UP-AVOID UNNECESSARY
STIRRING/HANDLING IN ORDRE TO PREVENT FORMATION OF DUST.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. USE ACCORDING
TO DIRECTION.
Other Precautions:DON'T BREATH DUST.
Exposure Controls
Respiratory Protection:NIOSH-APPROVED EQUIPMENT. ALSO SEE ANSI STANDARD
Z88.2-1980, PRACTICES FOR RESPIRATORY PROTECTION.
Ventilation:USE SUFFICIENT LOCAL EXHAUST TO REDUCE THE LEVEL OF
RESPIRABLE CRYSTALLINE SILICA TO THE PEL.
Protective Gloves:REQUIRED
Eye Protection:GOGGLES
Work Hygienic Practices:HANDLE IN ACCORDANCE W/GOOD PERSONAL HYGIENE &
SAFETY PRACTICES. THESE PRACTICES INCLUDE AVOIDING UNNECESSARY,
EXPOSURE.
Supplemental Safety and Health
Chemical Properties
Spec Gravity:2.35
Solubility in Water:INSOLUBLE
Appearance and Odor:GREY POWDER W/NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID
Hazardous Decomposition Products:MAY REACT W/HYDROFLUORIC ACID TO FORM
TOXIC SILICON TETRAFLUORIDE GAS.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS. LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.