BTCJT - 19775-000 NICAD STORAGE BATTERY CELL
- MSDS: BTCJT
- Manufacturer: SAFT AMERICA INC POWER SOURCES DIV
- Product Name: 19775-000 NICAD STORAGE BATTERY CELL
- National Stock Number: 6140-01-236-8602
Product Identification
Product ID:19775-000 NICAD STORAGE BATTERY CELL
MSDS Date:03/10/1994
FSC:6140
NIIN:01-236-8602
MSDS Number: BTCJT
Responsible Party
VALDOSTA, GA 31603
US
Emergency Phone: 912-247-2331
Info Phone: 912-247-2331
Preparer: BETH JAS
Cage: 09052
Contractor
Telephone: 912-247-2331
Cage: 09052
Ingredients
CADMIUM SUSPECTED HUMAN CARCINOGEN (ACGIH,IARC, & NTP)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: <7-13%
OSHA PEL 0.05 MG/CUM (CD)
ACGIH TLV: 0.01 MG/CUM
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE *93-4*
CAS: 21041-95-2
Fraction By Weight: ,7-13%
OSHA PEL 0.05 MG/CUM (CD)
NICKEL (SOLUBLE) (SUSPECTED HUMAN CARCINOGEN BY NTP, IARC,
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: <23-30%
OSHA PEL 1 MG/CUM
ACGIH TLV: 0.05 MG/CUM IC
NICKEL HYDROXIDE
CAS: 12054-48-7
RTECS: OR7040000
Fraction By Weight: <23-30%
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
POTASSIUM HYDROXIDE
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 44.9%
ACGIH TLV: 2 MG/CUM (CEILING)
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
COBALT HYDROXIDE
CAS: 1307-86-4
RTECS: GG0904000
Fraction By Weight: 0.5-1%
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS NO EXPOSURE IS
EXPECTED; HOWEVER, IF BATTERY IS INCINERATED, FUMES MAY IRRITATE
THE RESPIRATORY SYSTEM. CORROSIVE.
Explanation of Carcinogenicity:SEE INGREDIENTS
Effects of Overexposure:NONE UNDER NORMAL CONDITIONS; HOWEVER, IF
BATTERY IS INCINERATED, FUMES MAY CAUSE CHEST PAIN, COUGHING,
SWEATING CHILLS, SHORTNESS OF BREATH, WEAKNESS. CHRONIC: KIDNEY
DYSFUNCTION, LUNG INJURY.
Medical Cond Aggravated by Exposure:NONE UNDER NORMAL CONDITIONS;
HOWEVER, IF INCINERATED, FUMES MAY AGGREVATE RESPIRATORY, PROSTATE,
LIVER, AND KIDNEY DISORDERS.
First Aid
First Aid:IF CONTACT W/POTASSIUM OR SODIUM HYDROXIDE ELECTROLYTE, FLUSH
W/WATER FOR 15 MINS. INHALATION: REMOVE FROM EXPOSURE. OBTAIN
MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Extinguishing Media:SUITABLE FOR SURROUNDING MATERIAL
Fire Fighting Procedures:USE NIOSH APPROVED SCBA W/FULL PROTECTIVE
CLOTHING.
Accidental Release
Spill Release Procedures:IF POTASSIUM OR SODIUM HYDROXIDE ELECTROLYTE
IS SPILLED, NEUTRALIZE AND FLUSH W/WATER.
Neutralizing Agent:MILD ACID
Handling
Handling and Storage Precautions:DON'T BREAK OPEN CASE. ELECTROLYTE IS
CORROSIVE. DON'T MUTILATE OR SHORT CIRCUIT CASE.
Exposure Controls
Respiratory Protection:WEAR NIOSH/MSHA APPROVED SCBA.
Protective Gloves:IF CASE PUNCTURED, IMPERVIOUS
Eye Protection:IF CASE PUNCTURED, SAFETY GOGGLES
Other Protective Equipment:IF IN A FIRE, WEAR FULL PROTECTIVE CLOTHING.
Supplemental Safety and Health
THESE ARE SEALED CELL BATTERIES, THERE IS NO HAZARD UNDER NORMAL USE.
EXPOSURE CAN OCCUR ONLY IF BATTERY IS INTENTIONALLY OPENED OR
RUPTURED. THIS ITEM IS NOW MANAGED BY DLA, MAINTENANCE DONE BY
DLA-H MIS.
Chemical Properties
HCC:N1
Appearance and Odor:PRISMATIC NYLON CASE
Stability
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:METAL OXIDE FUMES DURING BURNING
Disposal
Waste Disposal Methods:DON'T INCINERATE. TREAT AS RCRA HAZARDOUS WASTE
AND DISPOSE I/A/W LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.