BTLCV - KENVERT #418
- MSDS: BTLCV
- Manufacturer: MACDERMID INC
- Product Name: KENVERT #418
- National Stock Number: 6850-00F005641
Product Identification
Product ID:KENVERT #418
MSDS Date:10/10/1988
FSC:6850
NIIN:00F005641
MSDS Number: BTLCV
Responsible Party
WATERBURY, CT 06702
US
Emergency Phone: 203-575-5700 313-644-5626
Info Phone: 203-575-5700 / FAX 203-575-7900
Cage: 1FK56
Contractor
Telephone: 203-575-5700
Cage: 1FK56
Ingredients
CHROMIUM (VI) OXIDE;CHROMIC ACID
CAS: 1333-82-0
RTECS: GB6650000
Fraction By Weight: <20%
OSHA PEL C, 0.1 MG/M3
ACGIH TLV: 0.05 MG/M3; 8990
HYDROGEN CHLORIDE (HYDROCHLORIC ACID) (SARA III)
CAS: 7647-01-0
RTECS: MW4025000
Fraction By Weight: 7%
OSHA PEL C 5 PPM
ACGIH TLV: C 5 PPM; 9394
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 80MG/KG,CHROMIC ACID
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYES:CAUSES BURNS.SKIN:CAUSES
BURNS.INHAL:VAPORS/MISTS MAY CAUSE RESPIRATORY
IRRITATION.INGEST:HARMFUL IF SWALLOWED.CHRONIC:INHALATION OF VAPORS
MAY CAUSE ULCERATION OF THE NASAL SEPTUM.
Explanation of Carcinogenicity:CHROMIUM+6 COMPOUNDS ARE SUSPECTED
CARCINOGENS LISTED BY NTP AND IARC.
Effects of Overexposure:INHAL:COUGHING,WHEEZING,BRONCHITIS,HEADACHE.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING
RESPIRATORY OR SKIN AILMENTS MAY BE AT INCREASED RISK FROM
EXPOSURE.
First Aid
First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH WATER.EYES:FLUSH
WITH WATER FOR 15 MINUTES.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN OR
ARTIFICIAL RESPIRATION IF NEEDED.INGEST:DO NOT INDUCE VOMITING.GET
PROMP T QUALIFIED MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE,FOAM,DRY CHEMICAL.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:FIRE CONDITIONS MAY EVOLVE TOXIC
FUMES.THIS PRODUCT CAN REACT WITH ORGANIC MATERIALS TO GENERATE
ENOUGH HEAT TO START A FIRE.
Accidental Release
Spill Release Procedures:SOAK UP WITH NON-COMBUSTIBLE INERT
ADSORBANT(EG.CLAY);PLACE COLLECTED MATERIEL IN AN APPROPRIATE
CONTAINER FOR DISPOSAL.DO NOT DISCHARGE TO SEWER.
Neutralizing Agent:SODIUM BICARBONATE,SODA ASH,LIME.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
PLACE.KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:KEEP AWAY FROM COMBUSTIBLE OR READILY OXIDIZABLE
MATERIALS.
Exposure Controls
Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE EITHER A SELF-CONTAINED BREATHING APPARATUS OR
A NOISH/MSHA APPROVED RESPIRATOR FOR ACID GAS,DEPENDING ON THE
AIRBORN CONCENTRATION.
Ventilation:LOCAL EXHAUST(FUME HOOD-PREFERRABLE).
Protective Gloves:RUBBER.
Eye Protection:CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:RUBBER APRON AND BOOTS,AS NEEDED.PROVIDE A
LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
AREA.
Supplemental Safety and Health
THE LD50 OF CHROMIC ACID ALSO PUTS THIS ITEM IN THE RANGE OF
POISON,CLASS III.
Chemical Properties
HCC:C1
Boiling Pt:B.P. Text:166F,74C
Vapor Pres:20
Vapor Density: 23
Spec Gravity:1.205
pH:<1
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID;DARK BROWN;ODORLESS
Percent Volatiles by Volume:76
Corrosion Rate:CORROSIV
Stability
Stability Indicator/Materials to Avoid:YES
STRONG REDUCING AGENT AND OXIDIZING AGENTS.
Stability Condition to Avoid:HIGH HEAT,SOURCES OF IGNITION.
Hazardous Decomposition Products:OXIDES OF SULFUR.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.THIS ITEM IS RCRA HAZARDOUS WASTE(TCLP-CHROMIUM).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.