BTLSD - HYDROGEN

Product Identification

Product ID:HYDROGEN
MSDS Date:04/12/1993
FSC:6830
NIIN:00N044251
MSDS Number: BTLSD

Responsible Party
SCIENTIFIC GAS PRODUCTS INC
2330 HAMILTON BLVD
SOUTH PLAINFIELD, NJ 07080
US

Emergency Phone: 201-754-7700

Info Phone: 201-754-7700

Cage: 54262

Contractor
SCOTT SPECIALTY GASES
SOUTH PLAINFIELD, NJ 07080 US

Telephone: 908-754-7700

Cage: 54262

Ingredients

GROUNDED, ESP GLASSWARE & PLASTIC TUBING WHICH ARE

RTECS: 9999999ZZ


MUST BE DESIGNED TO HANDLE MAXIMUM PRESS TO WHICH IT

RTECS: 9999999ZZ


LIGHTS & FIXTURES IN WORK AREA. TRANSPORT ALL

RTECS: 9999999ZZ


FLAMMABLE GAS MONITOR AT ALL TIMES WHEN WORKING

RTECS: 9999999ZZ


HYDROGEN

CAS: 1333-74-0

RTECS: MW8900000

OSHA PEL N/K

ACGIH TLV: SIMPLE ASPHYXIANT


SYS MUST BE CHECKED FOR LEAKS USING AN AQ SOAP

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TLV: SIMPLE ASPHYXIANT. CAUSES
ASPHYXIATION IF ALLOWED TO DISPLACE THE OXYGEN CONTENT IN THE
ATMOSPHERE NECESSARY TO SUSTAIN LIFE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:IF DIZZINESS OCCURS, REMOVE TO FRESH AIR IMMEDIATELY.
INGEST:CALL MD IMMEDIATELY . EYES:IMMEDIATELY FLUSH W/POTABLE WATER
FOR A MINIMUM OF 15 MINS. SEEK ASSISTANCE FROM MD . SKIN:FLU SH
W/COPIOUS AMOUNTS OF WATER. CALL MD .

Fire Fighting

Flash Point:FLAMMABLE GAS
Lower Limits:4%
Upper Limits:74.2%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR HALON
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. IF POSS, ELIM SOURCE OF GAS. OTHERWISE, ALLOW FIRE TO BURN UNDER
CONTROL UNTIL GAS SUPPLY IS (SUP DAT)
Unusual Fire/Explosion Hazard:IF FLAMES ARE EXTINGUISHED PRIOR TO
ELIMINATING GAS SUPPLY, EXPLOS REIGNITION MAY OCCUR. HYDROGEN BURNS
W/NO EVIDENT FLAME. DO NOT ENTER DANGER AREA (SUP DAT)

Accidental Release

Spill Release Procedures:EVACUATE AREA. REMOVE ALL POTENTIAL SOURCES OF
IGNITION. VENTILATE AREA, ESPECIALLY HIGH PLACES WHERE HYDROGEN
WILL RISE & ACCUMULATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HYDROGEN MUST BE STORED AWAY FROM
OXIDIZING AGENTS, E.G. OXYGEN, CHLORINE & FLUORINE. CYL STORED
OUTDOORS MUST BE PROTECTED FROM EXTREMES OF WEATHER.
Other Precautions:HYDROGEN IS EXTREMELY FLAMM & MUST BE STORED IN A
COOL, DRY, WELL-VENTD AREA & MUST BE PROTECTED FROM OPEN FLAMES,
SPARKS & OTHER POTNTL SOURCES OF IGNIT. THAW ACCUMULATED ICE OR
SNOW ON CYL AT ROOM T EMPS. NEVER USE A TORCH OR (SUP DAT)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED OXYGEN-DEFFICIENT
ATMOSPHERES ARE FLAMMABLE. DO NOT ENTER AREA.
Ventilation:MECHANICAL VENTILATION MUST COMPLY W/NEC FOR CLASS 1, GROUP
B.
Protective Gloves:FOR HANDLING CYLINDERS TYPE GLOVES.
Eye Protection:SAFETY GLASSES,GOGGLES AND/OR FACESHLD.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:DEPLETED. COOL CONTR W/WATER SPRAY BUT DO NOT EXTING
THE FLAMES. EXPLO HAZ:UNTIL GAS HAS DISSIPATED. FORMS EXPLOS MIX
W/AIR, OXYGEN & ALL OXIDIZING AGENTS. OTHER PREC:OTHER SOURCE OF I
NTENSE HEAT TO THAW ICE ON A CYL. "NO SMOKING" SIGNS MUST BE POSTED
IN ALL WORK & STOR AREAS. THE HYDROGEN GAS (ING 2)

Chemical Properties

HCC:G2
Boiling Pt:B.P. Text:-423F,-253C
Vapor Density:0.069
Solubility in Water:0.019 CC/CC WATER
Appearance and Odor:COLORLESS, ODORLESS GAS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:SPARKS, OPEN FLAMES & EXCESSIVE
TEMPERATURES.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:CONTACT SUPPLIER FOR DISPOSAL INSTRUCTIONS.
DISPOSAL MUST BE IN ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS
.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.