BTTJN - 101 3176 LIQUID DEVELOPER SYSTEM CLEANER, WORKING SOLUTION

  • MSDS: BTTJN
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: 101 3176 LIQUID DEVELOPER SYSTEM CLEANER, WORKING SOLUTION
  • National Stock Number: 6750-01-026-9410
Product Identification

Product ID:101 3176 LIQUID DEVELOPER SYSTEM CLEANER, WORKING SOLUTION
MSDS Date:12/17/1997
FSC:6750
NIIN:01-026-9410
Kit Part:Y
MSDS Number: BTTJN

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 800- 242-2424

Preparer: NOT PROVIDED

Cage: 19139

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000


SODIUM DICHROMATE

CAS: 10588-01-9

RTECS: HX7700000

OSHA PEL SEE TABLE Z-2

ACGIH TLV: 0.05 MG/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SULFURIC ACID

CAS: 7664-93-9

RTECS: WS5600000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NOT PROVIDED
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF EXPOSURE: INHALATION:
HARMFUL IF INHALED. EYES: CAUSES BURNS. SKIN: CAUSES IRRITATION.
HARMFUL IF ABSORBED THROUGH SKIN. MAY CAUSE ALLERGIC SKIN REACTION.
INGESTION: HARMFUL IF SWALLOWED. M AY CAUSE BURNS OF THE
GASTROINTESTINAL TRACT IF SWALLOWED.
Explanation of Carcinogenicity:INTERNATIONAL AGENCY FOR RESEARCH ON
CANCER (IARC): GROUP 1, STRONG INORGANIC MISTS OR VAPORS CONTAINING
SULFURIC ACID, HEXAVALENT CHROMIUM COMPOUNDS - AMERICAN CONFERENCE
OF GOVERNMENTAL INDUSTRIAL H YGIENISTS (ACGIH): GROUP A1 CONFIRMED
HUMAN CARCINOGEN, HEXAVALENT CHROMIUM COMPOUNDS -NATIONAL
TOXICOLOGY PROGRAM: HEXAVALENT CHROMIUM COMPOUNDS. OSHA: NONE
Effects of Overexposure:EYES: CAUSES BURNS. SKIN: CAUSES IRRITATION.
INGESTION: MAY CAUSE BURNS OF THE GASTROINTESTINAL TRACT IF
SWALLOWED.
Medical Cond Aggravated by Exposure:NOT PROVIDED

First Aid

First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES: IMMEDIATELY FLUSH WITH PLENTY
OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION
IMMEDIATELY. SKIN : IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING AND SHOES.
GET MEDICAL ATTENTION IF SYMPTOMS OCCUR. WASH CONTAMINATED CLOTHING
BEFORE REUSE. DESTR OY OR THOROUGHLY CLEAN CONTAMINATED SHOES.
INGESTION: DO NOT INDUCE VOMITING. GIVE VICTIM A GLASS OF WATER.
CALL A PHYSICIAN OR POISON CONTROL CENTER IMMEDIATELY. NEVER GIVE
ANYTHING BY MOUTH TO AN UN CONSCIOUS PERSON.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL,
THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NOT PROVIDED

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:DO NOT BREATHE MIST OR VAPOR. DO NOT GET IN EYES AND
AVOID CONTACT WITH SKIN AND CLOTHING. USE WITH ADEQUATE
VENTILATION. WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCENTRATIONS BELOW RECOMMENDED EXPOSURE LIMITS, AN APPROVED
RESPIRATOR MUST BE WORN. RESPIRATOR TYPE: FULL-FACE CARTRIDGE
RESPIRATOR ACID GAS WITH DU ST/MIST PREFILTER. IF RESPIRATORS ARE
USED, A PROGRAM SHOULD BE INSTITUTED TO ASSURE COMPLIANCE WITH OSHA
STANDARD 29 CFR 1910.134.
Ventilation:SUPPLEMENTARY LOCAL EXHAUST VENTILATION, CLOSED SYSTEMS, OR
RESPIRATORY PROTECTION MAY BE NEEDED IN SPECIAL CIRCUMSTANCES.
Protective Gloves:WEAR IMPERVIOUS GLOVES AND PROTECTIVE CLOTHING
APPROPRIATE FOR RISK OF EXPOSURE
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS (OR GOGGLES).
Other Protective Equipment:THE FOLLOWING GLOVES HAVE BEEN SHOWN TO BE
IMPERVIOUS UNDER THE INDICATED CONDITIONS: NEOPRENE RUBBER. EYE
BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
SUPPLEMENTARY LOCAL EXHAUST VENTILATION, CLOSED SYSTEMS, OR RESPIRATORY
PROTECTION MAY BE NEEDED IN SPECIAL CIRCUMSTANCES SUCH AS POORLY
VENTILATED SPACES, EVAPORATION FROM LARGE SURFACES, SPRAYING, H
EATING, ETC.

Chemical Properties

HCC:C3
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:>100.C, 212.F
Melt/Freeze Pt:M.P/F.P Text:NOT PROVIDED
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:(68F): 24 MBAR (18 MM HG)
Vapor Density:0.6
Spec Gravity:NOT AVAILABLE
pH:NOT AVAILABLE
Viscosity:NOT PROVIDED
Evaporation Rate & Reference:NOT PROVIDED
Solubility in Water:COMPLETE
Appearance and Odor:ODORLESS LIQUID.
Percent Volatiles by Volume:>99 WT
Corrosion Rate:NOT PROVIDED

Stability

Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NOT PROVIDED
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. CONTRACT WITH A LICENSED
CHEMICAL DISPOSAL AGENCY. SINCE EMPTIED CONTAINERS RETAIN PRODUCT
RESIDUE, FOLLOW LABEL W ARNINGS EVEN AFTER CONTAINER IS EMPTIED.

Toxicology

Toxicological Information:GENERAL: INTERNATIONAL AGENCY FOR RESEARCH ON
CANCER (IARC) HAS DETERMINED THAT OCCUPATIONAL EXPOSURE TO
HEXAVALENT CHROMIUM COMPOUNDS AND STRONG INORGANIC MISTS OR
VAPORS CONTAINING SULFURIC AC ID ARE CARCINOGENIC TO HUMANS.
BECAUSE THIS PRODUCT CONTAINS CHROMIUM IN A WATER-BASED SOLUTION,
IT IS VERY UNLIKELY TO BE AN INHALATION EXPOSURE HAZARD. THIS
PRODUCT IS NOT EXPECTED TO GENER ATE MISTS OR VAPORS WHEN
PRODUCT INSTRUCTIONS FOR MIXING AND USE ARE FOLLOWED.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:IT IS EXPECTED TO HAVE THE FOLLOWING PROPERTIES: NO
BIOCHEMICAL OXYGEN DEMAND AND NO POTENTIAL TO CAUSE OXYGEN
DEPLETION IN AQUEOUS SYSTEMS, A HIGH POTENTIAL TO AFFECT SOME
AQUATIC ORGANISMS, A HIGH POTENTIAL TO AFFECT SECONDARY WASTE
TREATMENT MICROBIAL METABOLISM, A HIGH POTENTIAL TO AFFECT THE
GERMINATION AND/OR EARLY GROWTH OF SOME PLANTS, A LOW POTENTIAL TO
BIOCONCENTRATE. AFTER DILUTION WITH A LARGE AMOUNT OF WATER,
FOLLOWED BY SECONDARY WASTE TREATMENT, THIS MATERIAL IS NOT
EXPECTED TO CAUSE ADVERSE ENVIRONMENTAL EFFECTS.

Transport

Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS
PRODUCT CALL THE KODAK WORLDWIDE TRANSPORTATION HAZMAT HOT LINE:
(716) 722-2400 BETWEEN 8 A.M. AND 5 P.M. (EASTERN STANDARD
TIME), MONDAY THROUGH FR IDAY.

Regulatory

SARA Title III Information:CHEMICAL(S) SUBJECT TO THE REPORTING
REQUIREMENTS OF SECTION 313 OR TITLE III OF THE SUPERFUND
AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 AND 40 CFR
PART 372: CHROMIUM (VI) COMPOUNDS
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:MATERIAL(S) KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER: HEXAVALENT CHROMIUM COMPOUNDS -
MATERIAL(S) KNOWN TO THE STATE OF CALIFORNIA TO CAUSE ADVERSE
REPRODUCTIVE EFFECTS: NONE