BTYQL - DMP LUBE AEROSOL
- MSDS: BTYQL
- Manufacturer: EASTERN EQUIPMENT CO INC
- Product Name: DMP LUBE AEROSOL
- National Stock Number: 6850-00N048352
Product Identification
Product ID:DMP LUBE AEROSOL
MSDS Date:09/01/1991
FSC:6850
NIIN:00N048352
MSDS Number: BTYQL
Responsible Party
COLUMBIA, SC 29203
US
Emergency Phone: 803-754-0542
Info Phone: 803-754-0542
Cage: 0EKY4
Contractor
Telephone: 803-754-0542
Cage: 0EKY4
Ingredients
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY
CAS: 64742-65-0
RTECS: PY8038500
OSHA PEL N/K
ACGIH TLV: N/K
OXYGENATED HYDROCARBON
OSHA PEL N/K
ACGIH TLV: N/K
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM; 30000 STEL
ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROEHANE) (SARA
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 73%
OSHA PEL 350 PPM; 450 STEL
ACGIH TLV: 350 PPM; 450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ETHANOL, 2-BUTOXY-; (BUTYL CELLOSOLVE)
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 2%
OSHA PEL 50 PPM, S
ACGIH TLV: 25 PPM, S
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (EG, EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAININ G USES IN HUMANS
ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . INHAL:EXCESIVE INHAL
CAN CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:MILDLY REFINED MINERAL OIL: IARC
MONOGRAPHS, SUPPLEMENT, VOL 7, PG 252, 1987:GROUP 1.
Effects of Overexposure:HLTH HAZ:RESP IRRIT, HDCH & UNCON. POSS DEATH.
SKIN:PRLNG CNTCT CAN CAUSE DERM. INGEST:CAN CAUSE GI IRRIT.
EYES:CAN CAUSE SEV IRRIT. CHRONIC: ANIMAL STUDIES HAVE SHOWN
DOSE-RELATED ADVERSE EFTS ON CNS , HEMATOPOIETIC TISS, BLOOD,
KIDNEYS & LIVER ASSOC W/ADMIN OF 2-BUTOXYETHANOL. (EXTRACTED FROM
DHHS (NIOSH) (SUPDAT)
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGRAVATED.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING DIFFICULT, GIVE
OXYGEN. IF BREATHING STOPPED, ADMINISTER ARTIFICIAL RESPIRATION.
GET MEDICAL ATTENTION. EYES: FLUSH WITH WATER, LIFTING UPPER/LOWER
LIDS. GET MEDICAL ATTENTION. SKIN: WASH EXPOSED AREA WITH SOAP &
WATER. INGESTION: DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TOC
Flash Point:150F,66C
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE . AT ELEVATED TEMPERATURES (ABOVE 120F)
CONTAINERS MAY VENT, RUPTURE OR BURST.
Accidental Release
Spill Release Procedures:CLEAN UP AREA BY MOPPING OR WITH ABSORBENT
MATERIALS AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE
120F.
Other Precautions:NO SMKNG IN AREA OF USE. DO NOT USE IN GEN VICIN OF
ARC WELDING, OPEN FLAMES/HOT SURF. HEAT &/OR UV RADIA MAY CAUSE
FORM OF HCL &/OR PHOSGENE . PLEASE READ & FOLLOW PROD LABEL
DIRECTIONS; THEY A RE BEST GUIDE TO USING PROD IN (SUPDAT)
Exposure Controls
Respiratory Protection:WHERE VAPOR CONCENTRATION IS BETWEEN 100 & 1000
PPM, A NIOSH/MSHA APPROVED ORGANIC VAPOR TYPE RESPIRATOR IS
ACCEPTABLE. OVER 1000 PPM, NIOSH/MSHA APPROVED SCBA OR AIR LINE
RESPIRATOR SHOULD BE WORN.
Ventilation:DO NOT USE IN CLOSED OR CONFINED SPACE. OPEN DOORS AND/OR
WINDOWS.
Protective Gloves:WEAR VITON, PVA OR EQUIVALENT GLOVES.
Eye Protection:SAFETY GLASSES OR CHEMICAL GOGGLES.
Other Protective Equipment:AVOID CONTACT WITH SKIN & AVOID BREATHING
VAPORS. ANSI APPROVED EYE WASH FOUNTAIN / DELUGE SHOWER .
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREA. WASH
HANDS BEFORE EATING.
Supplemental Safety and Health
EFTS OF OVEREXP: PUBLICATION NO 90-118). WASTE DISP METH: FACILITY.
CONSULT FEDERAL, STATE & LOCAL DISPOSAL AUTHORITIES FOR APPROVED
DISPOSAL PROCEDURES. OTHER PREC:MOST EFFECTIVE WAY & GIVE THE
NECESSARY SAFETY PRECAUTIONS TO PROTECT YOUR HEALTH.
Chemical Properties
Vapor Pres:90
Spec Gravity:1.186 (H*2O=1)
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR, YELLOWISH LIQUID; MILD SWEETISH ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS, ALUMINUM AND OTHER REACTIVE METALS.
Stability Condition to Avoid:DO NOT EXPOSE TO TEMPERATURES ABOVE 120F.
Hazardous Decomposition Products:HCL, PHOSGENE.
Disposal
Waste Disposal Methods:WHEN USED PROPERLY AEROSOL PRODS DO NOT GENERATE
HAZ WASTE. EMPTY DE-PRESSURIZED CNTNRS CANNOT BE REUSED & SHOULD BE
WRAPPED & PUT IN TRASH COLLECTION. CANS WHICH ARE PRESSURIZED/CNTN
LIQ MUST BE DISP OSED OF IN PERMITTED WASTE MANAGEMENT (SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.