BVCTN - G-135S INDUSTRIAL X-RAY DEVELOPER STARTER

  • MSDS: BVCTN
  • Manufacturer: AGFA CORP
  • Product Name: G-135S INDUSTRIAL X-RAY DEVELOPER STARTER
  • National Stock Number: 6750-00N049331
Product Identification

Product ID:G-135S INDUSTRIAL X-RAY DEVELOPER STARTER
MSDS Date:04/01/1988
FSC:6750
NIIN:00N049331
MSDS Number: BVCTN

Responsible Party
AGFA CORP
100 CHALLENGER RD
RIDGEFIELD PARK, NJ 07660
US

Emergency Phone: 303-623-5716;800-424-9300(CHEMTREC)

Info Phone: 201-440-2500

Cage: HO790

Contractor
AGFA DIVISION/BAYER CORPORATION
RIDGEFIELD PARK, NJ 07660 US

Telephone: 210-440-2500

Cage: 59710

Ingredients

ACETIC ACID (SARA III)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 10-15%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM; 15 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: (PERTAINS TO FINISHED PRODUCT)
EYES: MAY CAUSE IRRITATION. SKIN: NO DERMAL IRRITATION AS PER TEST
PERFORMED. INHAL: NORMALLY NO PROBLEM, BUT INHALATION OF MIST COULD
CAUSE RESPIRATORY IRRITATIO N. INGEST: MAY CAUSE IRRITATION OF THE
MUCOUS MEMBRANES OR DIGESTIVE TRACT. CHRONIC: A COMPUTERIZED (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: LITERATURE SEARCH OF NATIONAL
DATABASES DID NOT YIELD ANY CHRONIC EFFECTS ASSOCIATED WITH THESE
MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH WITH PLENTY OF RUNNING WATER FOR AT
LEAST 15 MINUTES. OBTAIN MEDICAL ATTENTION. SKIN: FLUSH AFFECTED
AREAS PROMPTLY WITH WATER FOR 15 MINUTES. REMOVE CONTAMINATED
CLOTHING. IN CASE OF CONTINUED IRRITATION CONSULT MD. INHALATION:
FOR OVEREXPOSURE, REMOVE TO FRESH AIR. INGESTION: OBTAIN IMMEDIATE
MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . EVACUATE PERSONNEL TO A SAFE AREA. KEEP
PERSONNEL REMOVED AND UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:REVIEW SFTY PREC & HAZ BEFORE PROCEEDING
W/CLEAN UP. USE APPROP PERSONAL PROT EQUIP DURING CLEAN UP. DIKE
SPILL. PVNT LIQ FROM ENTERING SEWERS, WATERWAYS/LOW AREAS. SOAK UP
W/SAWDUST, SAND, OIL DRY/OT HER ABOSRB MATL.
Neutralizing Agent:SPILL MAY BE NEUTRALIZED WITH SODIUM CARBONATE.

Handling

Handling and Storage Precautions:STORE IN WELL VENTILATED AREA. KEEP
CONTAINERS TIGHTLY CLOSED. DO NOT STORE WITH INCOMPATIBLE
MATERIALS.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NONE NEEDED WITH WORKING MIXTURES AND
NORMAL ROOM VENTILATION.
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:ANSI APPVD EYEGLSSES W/ SDSHLDS .
Other Protective Equipment:APRONS ARE RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: (WT) SAME AS WATER. WASTE DISP METH: DISCHARGE TO SEWER
REQUIRES APPROVAL OF PERMITTING AUTHORITY AND MAY REQUIRE
PRETREATMENT.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:AS WATER
Vapor Density:AS WATER
Spec Gravity:1.186 (H*2O=1)
pH:2
Evaporation Rate & Reference:SAME AS WATER
Solubility in Water:100%
Appearance and Odor:CLEAR AND COLORLESS; VINEGAR ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FED, STATE & LOCAL REGS .
RECOVER NONUSABLE FREE LIQ &/OR CONTAMD WATER & DISPOSE OF IN
APPRVD & PERMITTED TREATMENT SYS. REMOVE NONUSABLE SOLID MATL &/OR
CONTAMD SOIL FOR DISPOSAL IN APPRVD & PERMITTED LANDFILL. (SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.