BVJGV - POLYETHYLENE, CHLORO-SULFANATED, 107

Product Identification

Product ID:POLYETHYLENE, CHLORO-SULFANATED, 107
MSDS Date:03/01/1992
FSC:6810
NIIN:00N050022
MSDS Number: BVJGV

Responsible Party
SCIENTIFIC POLYMER PRODUCTS INC
6265 DEAN PARKWAY
ONTARIO, NY 14519
US

Emergency Phone: 716-265-0413

Info Phone: 716-265-0413

Cage: 0MWG0

Contractor
SCIENTIFIC POLYMER PRODUCTS INC
ONTARIO, NY 14519 US

Telephone: 716-265-0413

Cage: 0MWG0

Ingredients

POLYETHYLENE BASED RUBBER; (POLYETHYLENE, CHLOROSULFONATED)

CAS: 68037-39-8

Fraction By Weight: >98%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON TETRACHLORIDE (SARA III)

CAS: 56-23-5

RTECS: FG4900000

Fraction By Weight: 0.2%

OSHA PEL 10 PPM

ACGIH TLV: 5PPM; 10 STEL, S

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CHLOROFORM (SARA III)

CAS: 67-66-3

RTECS: FS9100000

Fraction By Weight: 0.02%

OSHA PEL 50 PPM, C

ACGIH TLV: 10 PPM

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)

CAS: 14807-96-4

RTECS: WW2710000

Fraction By Weight: 7.2%

OSHA PEL 50 PPM, C

ACGIH TLV: 10 PPM

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:HEATING OVER 260C PRODUCES HIGH VAPOR
CONCENTRATIONS. PROLONGED OR REPEATED CONTACT WITH SKIN MAY CAUSE
IRRITATION. CARBON TETRACHLORIDE RELEASED IN STORAGE AND DURING
PROCESS AS VAPOR IS IRRITATING T O RESPIRATORY TRACT.
Explanation of Carcinogenicity:CARBON TETRACHLORIDE: IARC MONOGRAPHS,
SUPPLEMENT, VOL 7, PG 143, 1987:GROUP 2B. NTP 6TH ANNUAL RPT ON
CARCIN, (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE FROM EXPOSURE. IF
BREATHING STOPS, BEGIN MOUTH TO MOUTH. EYES: FLUSH WITH WATER FOR
AT LEAST 15 MINUTES. SKIN: WASH AFFECTED AREA WITH SOAP AND WATER.
REMOVE DIRTY CLOTHING. IN ALL CASES, IF IRRITATION DEVELOPS, SEEK
MEDICAL ASSISTANCE.

Fire Fighting

Extinguishing Media:WATER FOG, FOAM, ALCOHOL FOAM, CARBON DIOXIDE, DRY
CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY GIVE OFF HYDROGEN CHLORIDE.

Accidental Release

Spill Release Procedures:SWEEP UP TO AVOID SLIPPING HAZARDS. TRANSFER
TO A CLOSED CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A DRY PLACE. KEEP CONTAINERS
CLOSED TO PREVENT CONTAMINATION. OPEN CONTAINERS ONLY IN
WELL-VENTILATED AREA.
Other Precautions:THIS MATERIAL IS INTENDED FOR LABORATORY USE ONLY. IT
IS NOT SOLD OR INTENDED FOR DRUG, HOUSEHOLD OR OTHER USES.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST ADEQUATE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:EYE BATH AND/OR SAFETY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN: 1991:ANTIC TO BE CARCIN. HUMAN:LIVER, KIDNEYS, LUNG
DMG. CHRLOROFORM: IARC MONOGRAPHS, SUPPLEMENT, VOL 7, PG 152,
1987:GROUP 2B. NTP 6TH ANNUAL RPT ON CARCIN, 1991:ANTIC TO BE
CARCIN . ANIMAL:LIVER/KIDNEY TUMORS, CNS EFTS.

Chemical Properties

Spec Gravity:1.11-1.27
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE CHIPS; SLIGHT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEATING ABOVE 260C.
Hazardous Decomposition Products:CARBON TETRACHLORIDE, HYDROGEN
CHLORIDE AND SULFUR DIOXIDE UNDER FIRE CONDITIONS.

Disposal

Waste Disposal Methods:LANDFILL OR INCINERATE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their