BWDQM - EPOXY-MODIFIED ACRYLIC FLOOR 52-
- MSDS: BWDQM
- Manufacturer: CORONADO PAINT CO
- Product Name: EPOXY-MODIFIED ACRYLIC FLOOR 52-
- National Stock Number: 8010-00N056170
Product Identification
Product ID:EPOXY-MODIFIED ACRYLIC FLOOR 52-
MSDS Date:04/08/1992
FSC:8010
NIIN:00N056170
MSDS Number: BWDQM
Responsible Party
EDGEWATER, FL 32132
US
Emergency Phone: 904-428-6461
Info Phone: 904-428-6461
Preparer: THOMAS E MAREK
Cage: 33200
Contractor
Telephone: 904-428-6461
Cage: 33200
Ingredients
0.10
CAS: 57-55-6
RTECS: TY2000000
Fraction By Weight: 2-4%
OSHA PEL N/K
ACGIH TLV: N/K
0.4-0.6 LBS PER GALLON
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:SLIGHT IRRITATION OR
REDNESS. INGESTION:NAUSEA. SKIN:MAY CAUSE IRRITATION OR RASH.
CHRONIC:NONE LISTED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . INGEST:INDUCE VOMITING & CALL PHYSICIAN AT ONCE. EYES:FLUSH
WITH WATER FOR @ LEAST 15 MINUTES AND CALL PHYSICIAN. SKIN:WASH AF
FECTED AREA WITH SOAP AND WATER.
Fire Fighting
Flash Point:NONE AT BOILING
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:CLEAN UP WITH WATER BEFORE ALLOWING TO DRY.
SODIUM CHLORIDE OR CALCIUM CHLORIDE MAY BE SPRINKLED ON SPILL; THIS
MAY COAGULATE LATEX AND FACILITATE CLEANING WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID PROLONGED OR REPEATED INHALATION
OF SPRAY MIST. USE WITH ADEQUATE VENTILATION.
Other Precautions:PAINT, WATER BASE. NO SPECIAL MAKINGS REQUIRED.
"PROTECT FROM FREEZING" WARNING SUGGESTED.
Exposure Controls
Respiratory Protection:SHOULD PREVENT INHALATION OF SPRAY MIST OR
HEATED VAPORS. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST AND GENERAL VENTILATION.
Protective Gloves:CHEM RESISTANT PLASTIC/RUBB GLOVES.
Eye Protection:ANSI APPRVD CHEMICAL GOGGLES .
Other Protective Equipment:AS REQUIRED TO PREVENT SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:1.15-1.25 (H*2O=1).
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:<0.01 (ETHER =1)
Solubility in Water:INFINITE
Appearance and Odor:WHITE OR COLORED OPAQUE LIQUID, SLIGHTLY SWEET ODOR
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:AFTER WATER HAS EVAPORATED, POLYMERIC
BINDER CAN BURN TO PRODUCE CARBON MONOXIDE AND CARBON DIOXIDE.
Disposal
Waste Disposal Methods:INCINERATE OR DISPOSE OF IN SANITARY LANDFILL IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.