BWMPG - DIPHENHYDRAMINE HYDROCHLORIDE
- MSDS: BWMPG
- Manufacturer: FUJISAWA USA INC (LYPHOMED INC)
- Product Name: DIPHENHYDRAMINE HYDROCHLORIDE
- National Stock Number: 6505-00-148-7177
Product Identification
Product ID:DIPHENHYDRAMINE HYDROCHLORIDE
MSDS Date:02/29/1988
FSC:6505
NIIN:00-148-7177
MSDS Number: BWMPG
Responsible Party
DEERFIELD, IL 60015-2548
US
Emergency Phone: 708-317-8800, 800-727-7003
Info Phone: 708-317-8800 (MEDICAL 317-8202)
Preparer: JANET L. JALACHI
Cage: 39832
Contractor
Telephone: 847-317-1256
Cage: 39832
Ingredients
DIPHENHYDRAMINE HYDROCHLORIDE
CAS: 147-24-0
RTECS: KR7000000
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 500 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE, SKIN & RESPIRATORY TRACT
IRRITATION. GASTOINTESTINAL DISTURBANCES, DROWSINESS, SEDATION,
DISTURBED COORDINATION, HYPOTENSION, DIZZINESS. CHRONIC: MAY CAUSE
CONGENITAL MALFORMATION IN FETUS .
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:EYE, SKIN & RESPIRATORY TRACT IRRITATION;
GASTROINTESTINAL DISTURBANCES, DRY MOUTH/NOSE/THROAT, DROWSINESS,
SEDATION, DISTURBED COORDINATION, HYPOTENSION, DIZZINESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALED-REMOVE TO FRESH AIR. REMOVE CONTAMINATED CLOTHING.
SEEK MEDICAL ATTENTION. INGESTED-FLUSH MOUTH OUT WITH WATER. SEEK
MEDICAL ATTENTION. SKIN-REMOVE CONTAMINATED CLOTHING. FLUSH AREA
WITH WATER . SEEK MEDICAL ATTENTION. EYES-FLUSH WITH WATER. SEEK
MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:WATER, CARBON DIXOIDE, DRY CHEMICAL, FOAM AS
APPROPRIATE FOR SURROUNDING FIRE AND MATERIALS.
Fire Fighting Procedures:FIREFIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS AND PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:PRODUCT EMITS TOXIC FUMES WHEN HEATED TO
DECOMPOSITION.
Accidental Release
Spill Release Procedures:WEAR RECOMMENDED PROTECTIVE
CLOTHING/EQUIPMENT. VACUUM SPILLAGE WITH VACUUM CLEANER W/HEPA
FILTER OR ABSORB LIQUID IN PAPER TOWEL. WIPE WORKING SURFACE TO
DRYNESS, THEN WASH WITH SOAP & WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AS A GENERAL RULE, WHEN HANDLING
PHARMACEUTICAL PRODUCTS, AVOID ALL CONTACT & INHALATION OF DUST,
FUMES, MISTS, AND/OR VAPORS ASSOCIATED WITH PRODUCT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR EMERGENCY OCCURS; USE NIOSH/MSHA APPROVED RESPIRATOR OR SUPPLIED
AIR RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29 CFR 1910.134 AND
MANUFACTURER'S RECO MMENDATIONS.
Ventilation:LOCAL EXHAUST REOMMENDED.
Protective Gloves:DISPOSABLE SURGICAL LATEX GLOVES.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:DISPOSABLE PROTECTIVE APPAREL. DLA-HMIS: EYE
WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
LYPHOMED, INC. WAS ACQUIRED BY FUJISAWA; THIS PRODUCT HAS BEEN
DICONTINUED BY FUJISAWA PER DLSC-TIR: D-DAY ITEM FOR DOD. BOX
CONTAINS 10, 22 GAUGE 1-1/4 IN. NEEDLE-SYRINGE UNITS CONTAINING 1
ML EACH.
Chemical Properties
HCC:T6
pH:4-6.5
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS SOLUTION; ALMOST ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:MAY DISCOLOR WHEN EXPOSED TO LIGHT.
Hazardous Decomposition Products:TOXIC FUMES WHEN HEATED TO
DECOMPOSITION.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:THOUGH NOT EPA REGULATED, WASTE SHOULD BE
DISPOSED OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.