BWQRH - INJECTION SOUR, 71068
- MSDS: BWQRH
- Manufacturer: ECOLAB INC
- Product Name: INJECTION SOUR, 71068
- National Stock Number: 7930-00N057453
Product Identification
Product ID:INJECTION SOUR, 71068
MSDS Date:03/01/1993
FSC:7930
NIIN:00N057453
MSDS Number: BWQRH
Responsible Party
ST PAUL, MN 55102
US
Emergency Phone: 800-328-0026
Info Phone: 800-553-8683
Cage: 0DAC4
Contractor
Telephone: 800-352-5326
Cage: 85884
Ingredients
FORMIC ACID (SARA 313) (CERCLA)
CAS: 64-18-6
RTECS: LQ4900000
Fraction By Weight: 15-40%
OSHA PEL 5 PPM
ACGIH TLV: 5 PPM;10 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN AND EYE: CAUSES SEV CHEM BURNS.
EYE CONT MAY CAUSE BLINDNESS. INGESTION: HARMFUL OR FATAL. CAUSES
CHEMICAL BURNS OF MOUTH, THROAT AND STOMACH. INHALATION: VAPORS OR
MIST CAUSE IRRITATION, INCLUDI NG BURNING TASTE, SNEEZING, COUGHING
AND DFCLTY BRTHG. PEOPLE WITH ASTHMA OR OTHER LUNG PROBLEMS MAY BE
MORE AFFECTED.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:IMMED FLUSH W/PLENTY OF COOL RUNNING WATER.REMOVE CONT
LENSES. CONTINUE FLUSHING FOR AT LST 15 MINS, HOLDING EYELIDS APART
TO ENSURE RINSING OF ENTIRE EYE. CALL PHYS IMMED. SKIN: IMMED FLUSH
W/PLE NTY OF COOL RUNNING WATER FOR AT LST 15MINS WHILE REMOVING
CONTAMD CLTHG SHOES. WASH CLTHG BEFORE REUSE. INGEST: RINSE MOUTH
AT ONCE; THEN DRINK 1-2 LRG GLASSES OF WATER/MILK. DO NOT INDUCE
(SUPDAT)
Fire Fighting
Flash Point Method:CC
Flash Point:>200F,>93C
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL OUTSIDE OF CONTAINERS WITH WATER IF EXP
TO FIRE. PROD ITSELF DOES NOT SUPPORT COMBUST.
Unusual Fire/Explosion Hazard:WILL ATTACK SOFT METALS AND RELEASE
FLAMMABLE HYDROGEN. THIS CAN BE DISSIPATED WITH ADEQUATE VENTING.
Accidental Release
Spill Release Procedures:REMOVE ALL IGNITION SOURCES. RECOVER FREE
LIQUID. ADD ABSORBENT TO SPILL AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:AVOID BREATHING MISTS OR VAPORS CONTAINING
PRODUCT. WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION SUFFICIENT TO KEEP AIRBORNE
CONCENTRATION BELOW CURRENT EXPOSURE LIMITS .
Protective Gloves:RUBBER GLOVES-PROT CUFF/GAUNTLET TYPE.
Eye Protection:ANSI APPROVED CHEM SAFETY GOGGS (SUPDAT)
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER WHICH
MEET ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATERIALS TO AVOID: HAZARDOUS VAPORS. FIRST AID PROCEDURES: VOMITING.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. INHALATION:
IMMEDIATELY MOVE TO FRESH AIR. CALL POISON CONTROL CENTER OR PH
YSICIAN IMMEDIATELY. EYE PROT: AND FULLLENGTH FACESHIELD .
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.06
pH:1.5
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, SHARP ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
CAN REACT VIOLENTLY W/ALKALINE MATLS/OXIDIZING AGENTS.DO NOT MIX
W/CHLORINATED DETERGENTS/SANITIZERS-WILL CAUSE (SUPDAT)
Stability Condition to Avoid:MIX ONLY WITH WATER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:CONSULT FEDERAL, STATE AND LOCAL AUTHORITIES FOR
RESTRICTIONS ON DISPOSAL OF CHEMICAL WASTE. UNUSED PRODUCT AS WASTE
IS CORROSIVE (D002) BY RCRA CRITERIA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.