BWQWX - SYNACETI 116, SP310

Product Identification

Product ID:SYNACETI 116, SP310
MSDS Date:08/10/1992
FSC:6810
NIIN:00N057606
MSDS Number: BWQWX

Responsible Party
SPECTRUM CHEMICAL MFG CORP
14422 S SAN PEDRO ST
GARDENA, CA 90248
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 310-516-8000

Cage: 63415

Contractor
SPECTRUM LABORATORY PRODUCTS INC
GARDENA, CA 90248-2027 US

Telephone: 310-516-9843

Cage: 63415

Ingredients

NON-HAZARDOUS INGREDIENTS

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:RESPIRATORY IRRITAITON.
INGEST:MAY LEAD TO GASTROINTESTINAL IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES, SEEK MEDICAL AID
IF DISCOMFORT PERSISTS. SKIN:FLUSH W/WATER. WASH W/MILD SOAP &
WATER. SEEK MEDICAL AID IF DISCOMFORT PERSISTS. INHAL:REMOVE TO
FRESH AIR. R ESTORE BREATHING IF REQUIRED; MEDICAL AID IF
NECESSARY. INGEST:DO NOT INDUCE VOMITING. CONTACT POISON CONTROL
CENTER OR GET MEDICAL AID.

Fire Fighting

Flash Point Method:COC
Flash Point:450F,232C
Extinguishing Media:DRY CHEMICAL, CO*2, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
DO NOT SPRAY WATER DIRECTLY INTO FIRE WHICH WILL CAUSE FROTHING &
EJECT BURNING MATL. USE WATER (SUPP DATA)
Unusual Fire/Explosion Hazard:VAPORS ARE HVR/AIR & MAY TRAVEL TO SOURCE
OF IGNITION. DO NOT PRESSURIZE, CUT, WELD, BRAZE EMPTY DRUM WHICH
MAY CONTAIN IGNITABLE RESIDUE.

Accidental Release

Spill Release Procedures:CONTAIN SPILL & STOP LEAK AT SOURCE. ELIMINATE
ANY SOURCE OF IGNITION. PUMP OFF INTO COVERED CONTAINER OR USE
ABSORBENT TO COLLECT SPILLED MATERIAL. PREVENT FROM CONTAMINATING
POTABLE WATER SOURCE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SOURCES OF
IGNITION. KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:DO NOT KEEP OILY RAGS IN CONTACT W/CLOTHING. THIS
PRODUCT IS NOT KNOWN OR EXPECTED TO BE HAZARDOUS, BUT, AS W/ALL
CHEMICALS, HANDLE W/CARE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: RECOMMENDED FOR WORKER COMFORT & TO MEET TLV
LIMIT. MECHANICAL (GENERAL): IF NECESSARY.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . KEEP ALL EXPOSED SKIN SURFACES COVERED.
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE. WASH
W/SOAP & WATER BEFORE SMOKING, EATING, DRINKING OR USING TOILET.
Supplemental Safety and Health
FIRE FIGHT PROC:SPRAY TO COOL AREA & TO PROTECT PERSONNEL.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>115F,>46C
Spec Gravity:0.82 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE FLAKES W/TYPICAL WAXY ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON, SMOKE.

Disposal

Waste Disposal Methods:DISPOSE OF MATERIAL IN CONFORMANCE W/ALL
APPLICABLE FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.