Product Identification

Product ID:UP100 URIPREP
MSDS Date:02/01/1995
FSC:6850
NIIN:00F039753
MSDS Number: BWXNM

Responsible Party
PICKERING LABORATORIES INC
1951 COLONY STREET SUITE S
MOUNTAIN VIEW, CA 94043-5000
US

Emergency Phone: 415-694-6700

Info Phone: 415-694-6700

Cage: 0YGW7

Contractor
PICKERING LABORATORIES INC
MOUNTAIN VIEW, CA 94043-5000 US

Telephone: 415-694-6700

Cage: 0YGW7

Ingredients

PERCHLORIC ACID *95-1*

CAS: 7601-90-3

RTECS: SC7500000

Fraction By Weight: 1%


NON-HAZARDOUS SALTS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Hazards

LD50 LC50 Mixture:ORAL LD50 (RATS): 1100 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF ACIDIC FUMES MAY CAUSE
DELAYED PULMONARY EDEMA, APNEA & FROTHY SPECTRUM DYSPNEA &
HEMOPTYSIS ARE POSSIBLE AFTER SEVERAL WEEKS AFTER EXPOSURE.
REPEATED EXPOSURES MAY CAUSE DENTAL EROSION, JAW NECROSIS,
BROCHIAL IRRITATION & FREGUENT ATTACKS OF BROCHIAL PNEUMONIA MAY
OCCUR.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:COUGHING, CHOKING, HEADACHE, DIZZINESS,
WEAKNESS, HYPOTENSION, CHESS TIGHTNESS, CYANOSIS, IRRITATION, COMA,
GI DISTURBANCES.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH W/PLENTY OF WATER FOR 15 MINS. SKIN:
IMMEDIATELY WASH W/COPIOUS AMOUNTS OF WATER & SOAP. INGESTION: IF
CONSCIOUS, GIVE LARGE QUANTITIES OF WATER IMMEDIATELY TO DILUTE
ACID. DON 'T INDUCE VOMITING. GIVE 1 OZ (30 ML) OF MILK OF
MAGNESIA. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:WATER SPRAY. LARGE: FLOOD W/WATER FROM A DISTANCE.
Fire Fighting Procedures:DON'T MOVE CONTAINERS IF EXPOSURE OF HEAT HAS
OCCURED. COOL CONTAINERS W/WATER FROM SIDE UNTIL FIRE IS WELL OUT.
USE WATER IN FLOODING AMOUNTS AS A FOG. (SUPP)
Unusual Fire/Explosion Hazard:PROLONGED EXPOSURE OF THE CONTAINERS TO
HEAT MAY RESULT IN VIOLENT RUPTURE. NON-EXPLOSIVE. (SEE SUPP).

Accidental Release

Spill Release Procedures:WEAR SAFETY GOGGLES & GLOVES. SOAK UP W/RAGS,
PAPER TOWELS, SPONGE. RINSE AWAY/DISCARD. WASH SITE W/SOAP & WATER.

Handling

Handling and Storage Precautions:KEEP TIGHTLY CLOSED. STORE IN COOL
PLACE.
Other Precautions:AVOID EYE & SKIN CONTACT & INHALATION. DON'T INGEST.

Exposure Controls

Protective Gloves:RUBBER/LATEX/VINYL
Eye Protection:CHEMICAL SAFETY GOGGLES/SAFETY GLASSES
Other Protective Equipment:LABORATORY COAT, SAFETY SHOWER W/EYE WASH
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
SPECIAL FIRE CONT'D: AVOID BREATHING CORROSIVE VAPORS, KEEP UPWIND. IF
THE FIRE ISN'T CONTROLLABLE, EVACUATE TO A RADIUS OF 1500 FT. FIRE
EXPLOSION CONT'D: ANHYDROUS FORM OF PERCHLORIC ACID MAY DECOMP OSE
SPONTANEOUSLY & EXPLOSIVELY TO RELEASE CORROSIVE FUMES OF HYDROGEN

Chemical Properties

Boiling Pt:B.P. Text: 212F
Melt/Freeze Pt:M.P/F.P Text: 32F
Vapor Pres:<17
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID W/A CHARACTERISTIC ODOR OF
COUGH DROP.

Stability

Stability Indicator/Materials to Avoid:YES
PRIMARY/SECONDARY AMINES.
Stability Condition to Avoid:TEMP >212F.
Hazardous Decomposition Products:ANHYDROUS FORM OF PERCHLORIC ACID:
CORROSIVE FUME OF HYDROGEN CHLORIDE/CHLORINE DIOXIDE.

Disposal

Waste Disposal Methods:THIS PRODUCT MAY BE SENT TO AN EPA-APPROVED
WASTE DISPOSAL FACILITY IAW/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,