Product Identification

Product ID:ULTRAFORM, WHITE 220
MSDS Date:12/01/1989
FSC:9330
NIIN:00N058314
MSDS Number: BXCTZ

Responsible Party
BASF CORP
100 CHERRY HILL RD
PARSIPPANY, NJ 07054
US

Emergency Phone: 201-316-3422

Info Phone: 201-316-3422

Preparer: W.P. TOLAND

Cage: BASFC

Contractor
BASF CORPORATION
PARSIPPANY, NJ 07054 US

Telephone: 201-316-3000 OR 800-424-3900

Cage: 0PK40

Ingredients

POLYOXYMETHYLENE CO-POLYMER

CAS: 25214-05-1

OSHA PEL N/K

ACGIH TLV: N/K


S-TRIOXANE; (1,3,5-TRIOXAN) (PRINCIPLE MONOMER)

CAS: 110-88-3

RTECS: YK0350000

OSHA PEL N/K

ACGIH TLV: N/K


1,3-DIOXACYCLOHEPTANE; (CO-MONOMER)

CAS: 505-65-7

OSHA PEL N/K

ACGIH TLV: N/K


GLASS FIBERS

OSHA PEL N/K

ACGIH TLV: N/K


STABILIZERS

OSHA PEL N/K

ACGIH TLV: N/K


FILLERS, UNSPECIFIED; (FILLERS)

OSHA PEL N/K

ACGIH TLV: N/K


HANDLING OF ULTRAFORM WHILE IN SOLID, PELLET FORM

RTECS: 9999999ZZ


MOLDED ARTICLES UNDER AMBIENT TEMPERATURES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ULTRAFORM ITSELF IS HARMLESS. MOLTEN
MATLS CAN CAUSE THERMAL BURNS. IF ULTRAFORM IS SUBJECTED TO
EXCESSIVE HEAT PRIMARY DECOMP PROD IS FORMALDEHYDE, WHICH HAS
PENETRATING ODOR THAT CAN IRRIT EYES & TH ROAT EVEN AT LOW CONCS.
NO ADVERSE EFTSHAVE BEEN OBSERVED IN HNDLG OF ULTRAFORM PROVIDED
THAT (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:WORKPLACE IS ADEQUATELY VENTILATED &
NORMAL SAFETY PRACTICES ARE FOLLOWED. IF FORMALDEHYDE IS RELS DUE
TO EXCESSIVE HEATING, STEPS MUST BE TAKEN TO ENSURE THAT TLV IS NOT
EXCEEDED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. OBTAIN MEDICAL
ATTENTION IF IRRITATION PERSISTS. SKIN:FLUSH CONTAMINATED SKIN
W/SOAP & WATER. OBTAIN MEDICAL ATTENTION IF IRRITATION PERSISTS.
THERMAL BURNS FROM CONTACT W/MOLTEN MATL SHOULD BE TREATED BY MD.
INHAL:REMOVE TO FRESH AIR. OTHER MEASURES ARE USUALLY UNNECESSARY.
OBTAIN MEDICAL ATTENTION IF IRRIT PERSISTS. INGEST:SEEK MEDICAL
ATTENTION.

Fire Fighting

Flash Point:>608F,>320C
Extinguishing Media:WATER MIST; CO*2; DRY CHEMICAL; FOAM. USE WATER
SPRAY TO COOL CONTAINERS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:FORMALDEHDYDE MAY BE RELS IF PROD IS
EXPOS TO EXCESSIVE HEAT/FIRE. AIRBORNE DUST MAY BE EXPLO.
EXPLOSIBILITY OF DUSTS INCR W/DECR PARTICLE SIZE, SO PROD(SUPDAT)

Accidental Release

Spill Release Procedures:RECLAIM FOR PROCESSING IF POSSIBLE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID EXTREME HEAT. PROT FROM MOISTURE
DURING TRANSPORTATION & STOR. PELLET-HNDLG EQUIP SHOULD BE GROUNDED
TO PVNT BUILDUP OF ELECTROSTATIC CHARGE.
Other Precautions:PELLETS ON FLOOR MAY BE SLIPPERY & CAUSE FALLS. AVOID
DUST ACCUMULATION. USING STATE-OF-THE-ART TECHNIQUES, INCL ADEQ
VENT AROUND PROCESSING EQUIP SHOULD NOT EXPOSE EMPLOYEES TO
FORMALDEHYDE. DURING I MPROPER USE, INCL, BUT NOT LTD (SUPDAT)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR IF NEEDED WHEN HANDLING MOLTEN MATERIALS. NIOSH/MSHA
APPROVED SUPPLIED-AIR OR SCBA IN EMERGENCY OR NON-ROUTINE
SITUATIONS.
Ventilation:LOCAL EXHAUST VENT AT SOURCE MAY BE NEEDED WHEN PROCESSING
MOLTEN MATL. GENERAL VENT SHOULD BE ADEQ FOR ROUTINE HNDLG.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:PROT CLTHG SHOULD BE WORN WHEN HNDLG MOLTEN
MATL. EYE WASH STATION & SAFETY SHOWER SHOULD BE NEAR WORK AREA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:1.35-1.6 (H*2O=1). EXPLO HAZ:OF FINES SHOULD BE MINIMIZED.
OTHER PREC:TO, EXCESSIVE HEATING/PROCESSING IN PRESENCE OF ACIDIC
MATLS/OXIDIZING AGENTS, RELS OF FORMALDEHYDE GAS MIGHT BE INCR TO
EXTENT THAT PERSONAL PROT EQUIP SHOULDBE WORN. NO ADVERSE EFTS OF
EXPOS TO FORMALDEHYDE ARE ANTIC DURING NORMAL(ING 7)

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>325F,>163C
Spec Gravity:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:ODORLESS OPAQUE PELLETS.

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/POLYVINYLCHLORIDE (PVC) MATLS WHEN PROCESSING ULTRAFORM;
ACIDS; STRONG OXIDIZERS.
Stability Condition to Avoid:AVOID EXTREME HEAT. DECOMPOSITION OCCURS
AT TEMPERATURES >240C.
Hazardous Decomposition Products:FORMALDEHYDE & CARBON MONOXIDE WHEN
PRODUCT IS EXPOSED TO EXCESSIVE HEAT.

Disposal

Waste Disposal Methods:PERMITTED LANDFILL OR INCINERATION. COMPLY
W/LOCAL, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.