Product Identification

Product ID:SPEED-E-NAMEL
MSDS Date:08/18/1986
FSC:8010
NIIN:00N006431
MSDS Number: BXPZT

Responsible Party
ZYNOLYTE PRODUCTS INC
2320 E DOMINGUEZ ST
CARSON, CA 90749
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 213-513-0700

Cage: 25461

Contractor
ZYNOLYTE PRODUCTS CO
6244 CARSON, CA 90749 US

Telephone: 310-513-0700

Cage: 25461

Ingredients

ALIPHATIC HYDROCARBON (SOLVENT)

Fraction By Weight: 5-20%

OSHA PEL N/K

ACGIH TLV: 500 PPM (MFR)


AROMATIC HYDROCARBON SOLVENT

Fraction By Weight: 0-9%

OSHA PEL N/K

ACGIH TLV: 200 PPM (MFR)


METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 30-45%

OSHA PEL 500 PPM; Z-2

ACGIH TLV: 50 PPM, A2

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPELLANT CONTAINING ING 5 & 6

RTECS: 9999999ZZ

Fraction By Weight: 25-35%

OSHA PEL N/K

ACGIH TLV: N/K


PROPANE, 2-METHYL; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000

OSHA PEL N/K

ACGIH TLV: N/K


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAIN ING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE:ANESTHETIC.
Explanation of Carcinogenicity:METHYLENE CHLORIDE:IARC MONO SUPP, VOL
7, PG 194, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCIN, 1994:ANTIC
TO BE (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:FLUSH W/COPIOUS AMOUNTS OF
WATER. CALL MD. . INHAL:REMOVE FROM AREA. CALL DR. EYES:FLUSH WITH
LARGE QUANTITIES OF CLEAR WATER FOR @ LEAST 15 MINUTES, TAKE TO
PHYS.

Fire Fighting

Flash Point:<20F,<-7C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT . KEEP COOL WITH WATER SPRAY. REMOVE
FROM FIRE AREA IF POSSIBLE.
Unusual Fire/Explosion Hazard:THERM DECOMP PRODS MAY INCL HCL &
PHOSGENE . PRESSURIZED PROD. MUST BE STORED @ TEMP BELOW 120F. DO
NOT STORE NEAR HEAT, SPARKS/OPEN FLAME. (SUPDAT)

Accidental Release

Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120 DEGREES F. DO
NOT PUNCTURE OR INCINERATE.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY
CAUSE FORMATION OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:USE IN WELL VENTILATED AREA. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORK GOGGLES .
Other Protective Equipment:EYE WASH FOUNTAIN AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:EXPOSURE TO HEAT MAY CAUSE BURSTING. DO NOT PUNCTURE/INCIN
(BURN). USE IN WELL VENTILATED AREA. EXPLAN OF CARCIN:CARCIN.
ANIMAL:LUNG, LIV, SALIVARY, MAMARY GLAND (TUMORS).

Chemical Properties

Vapor Density:HVR/AIR
Spec Gravity:0.79-1.02
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT KNOWN
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:80-95

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:STORAGE ABOVE 120 DEGREES F.
Hazardous Decomposition Products:HCL & PHOSGENE .

Disposal

Waste Disposal Methods:FULL OR EMPTY CONTAINERS SHOULD NOT BE PUNCTURED
OR INCINERATED. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.