Product Identification
Product ID:PELCO COLLOIDAL GRAPHITE, 16053
MSDS Date:05/10/1991
FSC:6810
NIIN:00N059603
MSDS Number: BXTQM
Responsible Party
US
Emergency Phone: 916-243-2200
Info Phone: 916-243-2200
Cage: 5S624
Contractor
Telephone: 916-243-2200
Cage: 5S624
Ingredients
ISOPROPYL ALCOHOL; (ISOPROPANOL) (SARA 313)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 66%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM/500STEL
GRAPHITE
CAS: 7782-42-5
RTECS: MD9659600
Fraction By Weight: 15%
OSHA PEL 15 MPPCF
ACGIH TLV: 2 MG/M3 RDUST
BUTYL ALCOHOL; (N-BUTYL ALCOHOL) (SARA 313) (CERCLA)
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: 5%
OSHA PEL 100 PPM
ACGIH TLV: C 50 PPM, S
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
2,4-PENTANEDIOL, 2-METHYL-; (HEXYLENE GLYCOL)
CAS: 107-41-5
RTECS: SA0810000
Fraction By Weight: 5%
OSHA PEL C 25 PPM
ACGIH TLV: C 25 PPM
2-PROPANOL, 1-METHOXY-; (PROPYLENE GLYCOL MONOMETHYL ETHER)
CAS: 107-98-2
RTECS: UB7700000
Fraction By Weight: 5-10%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM/150STEL
773G/L
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: MAY CAUSE SEV IRRIT,
BURNING SENSATION, BLURRED VISION. SKIN: RPTD/PRLNG CONT CAN CAUSE
IRRIT & DERM. INHAL: EXCESS INHAL OF VAPS/MISTS CAN CAUSE NASAL &
RESP IRRIT, DIZZ, NAUS, HDCH. ING EST: CAN CAUSE GI IRRIT, NAUS,
VOMIT & DIARR. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER &
LOWER LIDS OCCASIONALLY, & SEEK MED ATTENTION IMMED. SKIN: WASH
W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE
REUSE. INHAL: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT,
ADMINISTER OXYGEN. IF BREATHING HAS STOPPED, GIVE ARTIFICIAL
RESPIRATION & SEEK MED ATTENTION IMMED. INGEST: KEEP INDIVIDUAL
CALM & SEEK MED ATTN IMMED
Fire Fighting
Flash Point Method:TCC
Flash Point:52.0F,11.1C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP AWAY FROM SPARKS, OPEN FLAMES OR
OTHER SOURCES OF IGNITION.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION AND VENTILATE
AREA. APPLY ABSORBENT MATERIAL AND TRANSFER TO CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID PROLONGED INHALATION OF MISTS OR
VAPORS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF THE TLV OF THE PRODUCT IS EXCEEDED, A
NIOSH/MSHA APPROVED MECHANICAL RESPIRATOR OR SCBA IS ADVISED.
Ventilation:PROVIDE SUFFICIENT LOCAL EXHAUST VENTILATION TO MAINTAIN
EXPOSURE BELOW TLV(S).
Protective Gloves:SOLVENT-RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS (SUP DAT)
Other Protective Equipment:NO SPECIAL EQUIP DEEMED NEC UNDER NORMAL
USAGE. EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EYE PROT: GOGGLES AND FULL LENGTH FACESHIELD .
Chemical Properties
Vapor Pres:31.00
Spec Gravity:0.89
Solubility in Water:PARTIAL
Appearance and Odor:THIXOTROPIC BLACK FLUID, WITH SHARP ODOR
Percent Volatiles by Volume:80
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.