BXVHD - RAZE
- MSDS: BXVHD
- Manufacturer: DRUMMOND AMERICAN CORP
- Product Name: RAZE
- National Stock Number: 6840-00D004019
Product Identification
Product ID:RAZE
MSDS Date:12/01/1994
FSC:6840
NIIN:00D004019
MSDS Number: BXVHD
Responsible Party
VERNON HILLS, IL 60061
US
Emergency Phone: 708-913-9313 OR 303-621-5716
Info Phone: 708-913-9313
Preparer: GARY OLSON
Cage: 64557
Contractor
Telephone: 708-913-9313
Cage: 64557
Ingredients
AROMATIC PETROLEUM SOLVENT (DISTILLATES, RESIDUE, LOW
CAS: 68477-31-6
RTECS: JN9500000
PROPANE (BLENDED WITH INGREDIENT 2- TOTAL PERCENTAGE IS
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: <30%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT; 9495
ISOBUTANE (BLENDED WITH INGREDIENT 1- TOTAL PERCENTAGE IS
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: <30%
PERMETHRIN
CAS: 52645-53-1
RTECS: GZ1225000
Fraction By Weight: >0.1%
D-TRANS ALLETHRIN (ALLETHRIN)
CAS: 584-79-2
RTECS: GZ1925000
Fraction By Weight: >0.2%
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS >5000 MG/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATES EYES. PROLONGED OR REPEATED
CONTACT MAY IRRITATE SKIN. INGESTION/INHALATION/CHRONIC: NONE
SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:PER MFR-NO INGREDIENT OF A CONCENTRATION
OF 0.1% OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED
CARCINOGEN.
Effects of Overexposure:EYES-IRRITATION. SKIN-IRRITATION.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING SKIN AND EYE
CONDITIONS.
First Aid
First Aid:SKIN-WASH HANDS WITH SOAP & WATER. EYES-FLUSH WITH WATER. SEE
PHYSICIAN IF IRRITATION PERSISTS. INHALED/INGESTION-NONE SPECIFIED
BY MANUFACTURER.
Fire Fighting
Flash Point Method:TOC
Flash Point:NON-FLAMMABLE
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: WATER
FOG, CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: WEAR
SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE GEAR. COOL
FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:USE ABSORBENT MATERIAL TO COLLECT AND CONTAIN
FOR SALVAGE OR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:WASH HANDS THOROUGHLY AFTER HANDLING.
Other Precautions:TOXIC TO AQUATIC LIFE. EMPTY CONTAINERS ARE SUBJECT
TO PROPER DISPOSAL. SARA 313: NO LISTED SUBSTANCES SUBJECT TO
REPORTING.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IN ACCORDANCE
WITH 29 CFR 1910.13 4 AND MANUFACTURER'S RECOMMENDATIONS.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION TO MAINTAIN EXPOSURE
BELOW TLV(S).
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER SHOULD BE
AVAILABLE FOR EMERGENCY USE.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING WASHROOM. DO
NOT SMOKE WHEN USING.
Supplemental Safety and Health
Chemical Properties
HCC:G3
Vapor Density:>1
Spec Gravity:0.99
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:WHITE-STRAW YELLOW MILKY EMULSION; FAINT AROMATIC
DISTILLATE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NOT APPLICABLE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.