BXWFS - NITROGEN

Product Identification

Product ID:NITROGEN
MSDS Date:05/01/1983
FSC:4210
NIIN:01-250-6424
MSDS Number: BXWFS

Responsible Party
UNION CARBIDE CORP INDUSTRIAL CHEMICALS DIV
39 OLD RIDGEBURY ROAD
DANBURY, CT 06817-0001
US

Emergency Phone: 800-822-4357

Info Phone: 800-822-4357

Cage: 61637

Contractor
UNION CARBIDE CORP
DANBURY, CT 06817-0001 US

Telephone: 800-822-4357/732-563-5522 (MSDS)

Cage: 61637

Ingredients

NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: 100%

ACGIH TLV: ASPHYXIANT; 9495

Hazards

LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NITROGEN ACTS AS AN ASPHYXIANT BY
DISPLACING OXYGEN & MAY CAUSSE ATMOSPHERES DEFICIENT IN OXYGEN IN
CLOSED SPACES & WHEN VENTILATION IS DEFICIENT.
Explanation of Carcinogenicity:MANUFACTURER GAVE NO INFORMATION ABOUT
CARCINOGENICITY. HMIS FOUND NO LISTING & DOES NOT EXPECT IT TO BE
CARCINOGENIC.
Effects of Overexposure:HEADACHE, BREATHING & PULSE RATES INCREASED,
DIFFICULT BREATHING, PERSPIRATION, DIZZINESS, RINGING IN EARS, LIPS
BLUE, TREMORS & WEAKNESS, FATIGUE UPON EXERTION, DROWSINESS, NAUSEA
& VOMITING, UNCONSC IOUSNESS.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION ON MSDS.

First Aid

First Aid:REMOVE FROM OXYGEN DEFICIENT ATMOSPHERE. IF BREATHING IS
DIFFICULT, ADMINISTER OXYGEN. IF NOT BREATHING ADMINISTER
ARTIFICIAL RESPIRATION, PREFERRATLY W/SIMULTANEOUS ADMINISTRATION
OF OXYGEN. CALL A P HYSICIAN. KEEP UNDER MEDICAL OBSERVATION FOR 24
HOURS IF RENDERED UNCONSCIOUS DUE TO OXYGEN DEFICIENCY.

Fire Fighting

Extinguishing Media:NITROGEN CANNOT CATCH FIRE. USE MEDIA APPROPRIATE
FOR SURROUNDING FIRE.
Fire Fighting Procedures:EVACUATE PERSONNEL FROM DANGER AREA. DELUGE
CONTAINERS W/WATER SPRAY FROM MAX DISTANCE UNTIL COOL, THE MOVE
THEM FROM FIRE AREA IF W/O RISK.
Unusual Fire/Explosion Hazard:CANNOT CATCH FIRE CONTAINER MAY RUPTURE
DUE TO HEAT OF FIRE. DO NOT SUBJECT CONTAINER TO >52C (125F). MOST
CONTAINERS ARE DESIGNED TO VENT CONTENTS W/HEAT.

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA. USE
SELF-CONTAINED BREATHING APPARATUS WHERE NEEDED. SHUT OFF LEAK IF
W/O RISK. VENTILATE AREA OF LEAK OR MOVE LEAKING CONTAINER TO WELL
VENTILATED AREA. TEST AREA FOR SUFFICIENT OXYGEN PRIOR TO
RE-ENTRY.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

Handling

Handling and Storage Precautions:MFR GAVE NO INFORMATION ON MSDS.
Other Precautions:MFR GAVE NO INFORMATION ON MSDS.

Exposure Controls

Respiratory Protection:SELF-CONTAINED BREATHING APPARATUS WHERE NEEDED.
Ventilation:LOCAL EXHAUST PREFERRED. GENERAL MECHANICAL VENTILATION IS
ACCEPTABLE.
Protective Gloves:PREFERRED FOR HANDLING CYLINDERS.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:METATARSAL SHOES FOR CYLINDER HANDLING.
Work Hygienic Practices:MFR:? HMIS:USE GOOD INDUSTRIAL HYGIENE
PRACTICES. MINIMIZE CONTACT & WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:G3
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Pres:GAS
Vapor Density:0.97
Spec Gravity:GAS
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS,ODORLESS
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE CURRENTLY KNOWN
Stability Condition to Avoid:MFR GAVE NO INFORMATION ON MSDS.
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR. NONE CURRENTLY
KNOWN.

Disposal

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE. DISCARD ANY
PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR LINER IN AN
ENVIRONMENTALLY ACCEPTABLE MANNER I/A/W FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.