BXYJZ - DERUSTO GALV-A-GRIP BRUSH GRADE G-35 BLACK

  • MSDS: BXYJZ
  • Manufacturer: DAP INC
  • Product Name: DERUSTO GALV-A-GRIP BRUSH GRADE G-35 BLACK
  • National Stock Number: 8030-00N048542
Product Identification

Product ID:DERUSTO GALV-A-GRIP BRUSH GRADE G-35 BLACK
MSDS Date:02/16/1989
FSC:8030
NIIN:00N048542
MSDS Number: BXYJZ

Responsible Party
DAP INC
DAYTON, OH 45401-0277
US

Emergency Phone: 800-535-5053

Info Phone: 800-543-3840

Cage: 90300

Contractor
DAP INC.
277 DAYTON, OH 45401-0277 US

Telephone: 513-253-7154/800-543-3840

Cage: 90300

Ingredients

TALC (POWDER) CONTAINING NO ASBESTOS FIBERS; (TALC)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 15-20%

OSHA PEL 20 MPPCF Z-3

ACGIH TLV: 2 MG/M3 RDUST


STODDARD SOLVENT; (MINERAL SPIRITS)

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 10-15%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


NAPHTHA PETROLEUM, HEAVY ALKYLATE C9-C12; (PETROLEUM

CAS: 64741-65-7

Fraction By Weight: 5-10%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM


IRON (III) OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: 5-10%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5MG/M3 FUME (FE)


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 1-5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


KEROSENE (PETROLEUM), HYDROTREATED; (PETROLEUM DISTILLATES)

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 1-3%

OSHA PEL N/K

ACGIH TLV: N/K


VOLATILE ORGANIC COMPOUND LESS WATER LESS EXEMPT SOLVENT

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY IRRIT EYES, SKIN, NOSE &
UPPER RESP TRACT. HARMFUL IF INHALED. HARMFUL/FATAL IF SWALLOWED.
IF INGESTED, MAY CAUSE VOMIT, DIARR & DEPRESSED RESPIRATION. INHAL
MAY AFFECT BRAIN/NERVOUS SYS CA USING DIZZ, HDCH OR NAUS. REMOVAL
OF PROD AFTER USE WILL RSLT IN GENERATION OF DUST. EXPOS TO DUST
MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: RSLT IN BUILD-UP OF MATL IN EYES,
EARS, NOSE & MOUTH WHICH MAY CAUSE IRRIT. CHRONIC: REPORTS HAVE
ASSOC PERM BRAIN & NERVOUS SYS DMG W/PRLNG & RPTD OCCUP OVEREXP TO
SOLVS. PRLNG/RPTD CNTCT W /SKIN CAN CAUSE DEFAT OF SKIN WHICH
MAYLEAD TO DERM. IF DRY SANDED, INHAL OF DUST MAY RSLT IN PULM &
RESP DMG. (SUPDAT)
Medical Cond Aggravated by Exposure:ASTHMA AND ASTHMA-LIKE CONDITIONS
MAY WORSEN FROM PROLONGED AND CONTINUOUS EXPOSURE.

First Aid

First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. CONTACT MD IMMEDIATELY. SKIN: WASH IMMEDIATELY WITH SOAP
AND WATER. INHAL: REMOVE TO FRESH AIR. CONTACT MD IMMEDIATELY.
INGEST: DO NOT INDUCE VOMITING. IMMEDIATELY CONTACT MDOR REGIONAL
POISON CONTROL CENTER FOR FURTHER TREATMENT.

Fire Fighting

Flash Point Method:CC
Flash Point:105F,41C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:CNTNRS MAY EXPLODE IF EXPOSED TO EXTREME
HEAT. ELIM SOURCES OF IGNIT: HEAT, ELEC EQUIP, SPARKS & FLAMES. DO
NOT PUT IN CNTCT W/OXIDIZING OR CAUSTIC MATERIALS.

Accidental Release

Spill Release Procedures:DIKE SPILL AREA. ABSORB REMAINING LIQUID WITH
ABSORBENT MATERIAL OR SCRAPE UP DRIED MATERIAL AND PLACE INTO
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM CAUSTICS & OXIDIZERS.
KEEP CNTNRS AWAY FROM EXCESSIVE HEAT & FREEZING. KEEP CNTNRS
TIGHTLY CLSD WHEN NOT IN USE. KEEP OUT OF (SUPDAT)
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF 8-HR EXPOS LIM/VALUE IS EXCEEDED FOR ANY
COMPONENT, USE APPRVD NIOSH/MSHA RESP. CONSULT SFTY EQUIP SUPPLIER
& OSHA REG 29 CFR 1910.134 FOR RESP REQS. USE APPRVD NIOSH/MSHA
RESP IF SANDING DRIED PAI NT OR DURING SPRAY APPLICATIONS.
Ventilation:PROVIDE SUFFICIENT MECH VENT (LOC/GEN EXHST) TO MAINTAIN
EXPOS BELOW PEL & TLV. VAPS ARE HVR/AIR & WILL COLLECT (SUPDAT)
Protective Gloves:SOLVENT IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:PROVIDE EYEWASH & SOLVENT IMPERVIOUS APRON
IF BODY CONTACT WITH PRODUCT MAY OCCUR. BARRIER CREAMS MAY BE USED.
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EFTS OF OVEREXP: INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING &
INHALING VAPORS MAY BE HARMFUL OR FATAL. HNDLG/STOR PRECS: REACH OF
CHILDREN. DO NOT STORE AT TEMPS ABOVE 120F. VENT: IN LOW AREAS.
CHECK ALL LOW AREAS (SUMPS, BASEMENTS, ETC.) BEFORE ENTERING.

Chemical Properties

Boiling Pt:B.P. Text:>310F,>154C
Vapor Pres:2 @ 20C
Vapor Density:5.0
Spec Gravity:1.4-1.6(H*2O=1)
Evaporation Rate & Reference:0.06 (TOLUENE =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:OPAQUE LIQUID WITH A GASOLINE-LIKE ODOR.
Percent Volatiles by Volume:40-50

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS AND CAUSTICS.
Stability Condition to Avoid:EXCESSIVE HEAT AND FREEZING.
Hazardous Decomposition Products:NORMAL COMBUSTION PRODUCTS, I.E. CO*X,
NO*X.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO FEDERAL, STATE AND LOCAL
REGULATIONS. DISCARDED MATERIAL SHOULD BE INCINERATED AT A
PERMITTED FACILITY. LIQUIDS CANNOT BE DISPOSED OF IN A LANDFILL. DO
NOT REUSE EMPTY CONTAINE RS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their