BXZGK - SILVER NITRATE APPLICATION,40606

  • MSDS: BXZGK
  • Manufacturer: G FIVE CORP
  • Product Name: SILVER NITRATE APPLICATION,40606
  • National Stock Number: 6505-00-299-9672
Product Identification

Product ID:SILVER NITRATE APPLICATION,40606
MSDS Date:08/01/1988
FSC:6505
NIIN:00-299-9672
MSDS Number: BXZGK

Responsible Party
G-FIVE CORPORATION
50 GORDON DRIVE
SYOSSET, NY 11791
US

Emergency Phone: 516-736-7447

Info Phone: 516-496-3700

Cage: FIVEC

Contractor
MOORE MEDICAL CORP (203-225-4621)
UNKNOW SYOSSET, NY 11791 US

Telephone: 516-496-3700

Cage: 1EU19

Ingredients

SILVER NITRATE (SARA 313) (CERCLA) (PERCENTAGE BASED ON

CAS: 7761-88-8

RTECS: VW4725000

Fraction By Weight: 75%

OSHA PEL 0.01 MG(AG)/M3

ACGIH TLV: 0.01 MG(AG)/M3; 9495

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POTASSIUM NITRATE (THIS INGREDIENT AND ITS PERCENTAGE IS

CAS: 7757-79-1

RTECS: TT3700000

Fraction By Weight: 25%

Hazards

LD50 LC50 Mixture:LD50 (ORAL, RAT) IS UNKNOWN.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:EYE, SKIN, RESPIRATORY &
GI TRACTS. ACUTE- MAY CAUSE SEVERE EYE IRRITATION & BURNS. MAY
CAUSE SKIN DISCOLORATION & BURNS. INHALATION OF DUST MAY CAUSE
NOSE, THROAT & LUNGS IRRITATION. IN GESTION MAY CAUSE BURNS TO
MOUTH & THROAT, & ABDOMINAL PAIN. CHRONIC- BLUE/GRAY DISCOLORATION
OF SKIN, EYES, NOSE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SEVERE IRRITATION, TEARING, PAIN, REDNESS, SKIN
DISCOLORATION, BURNS, NAUSEA, VOMITING

First Aid

First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALED:REMOVE TO FRESH
AIR. PROVIDE CPR/OXYGEN IF NEEDED. EYES:FLUSH WITH WATER FOR 15
MINUTES, HOLDING EYELIDS OPEN. SKIN:WASH WITH SOAP & WATER. ORAL:DO
NOT IN DUCE VOMITING. IF CONSCIOUS, RINSE MOUTH WITH WATER. SEEK
IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:SCC
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS OPERATED IN POSITIVE PRESSURE
MODE.
Unusual Fire/Explosion Hazard:MATERIAL IS AN OXIDIZER.

Accidental Release

Spill Release Procedures:SWEEP UP OR VACUUM SPILL. PLACE IN METAL
SAFETY CAN.
Neutralizing Agent:NOT RELEVANT

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL-VENTILATED
PLACE. KEEP CONTAINERS CLOSED. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:AS A GENERAL RULE, WHEN HANDLING PHARMACEUTICAL OR
LABORATORY PRODUCTS, AVOID ALL FORMS OF CONTACT AND INHALATION OF
DUST, FUMES, MISTS, AND/OR VAPORS ASSOCIATED WITH THE PRODUCT. WASH
THOROUGHLY AFTE R HANDLING AND BEFORE EATING OR DRINKING

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:GOOD VENTILATION
Protective Gloves:NEOPRENE OR LATEX
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:SAFETY SHOWER AND EYE WASH FOUNTAIN SHOULD
BE LOCATED NEARBY. WEAR APPROPRIATE PROTECTIVE CLOTHING FOR RISK OF
EXPOSURE.
Work Hygienic Practices:OBSERVE GOOD INDUSTRIAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. WASH THOROUGHLY BEFORE EATING,
DRINKING/SMOKING.
Supplemental Safety and Health
PERCENTAGES REFLECTED IN INGREDIENTS ARE FROM INFORMATION SUPPLIED BY
DLSC-TIR NOT(!) FROM THE MANUFACTURER. THE MSDS DID NOT HAVE ANY
DATE AND THE MANUFACTURER COULD NOT PROVIDE ONE. NO CHANGE IN MSD S
DATE WAS MADE.

Chemical Properties

HCC:D1
NRC/State Lic Num:NOT RELEVANT
Spec Gravity:4.2
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:40 G PER CENT @ 77F
Appearance and Odor:CLEAR WHITE CTRYSTALS; NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AMMONIA, ETHANOL, PEROXIDE, OXALIC ACID, SULFURIC ACID
Stability Condition to Avoid:LIGHT (MATERIAL DARKENS)
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS. SEND TO REFINERY FOR RECOVERY OF
SILVER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.