BYHHS - TIN

Product Identification

Product ID:TIN
MSDS Date:01/04/1996
FSC:6810
NIIN:00-241-1186
MSDS Number: BYHHS

Responsible Party
CAROLINA BIOLOGICAL SUPPLY COMPANY
2700 YORK ROAD
BURLINGTON, NC 27302
US

Emergency Phone: 910-584-0381/800-424-9300(CHEMTREC)

Info Phone: 910-584-0381

Cage: 59896

Contractor
CAROLINA BIOLOGICAL SUPPLY CO
BURLINGTON, NC 27215-3387 US

Telephone: 800-227-1150/910-584-0381

Cage: 59896

Ingredients

TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 90-100%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9192

Hazards

LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE EYE IRRITATION. MAY CAUSE
SKIN IRRITATION. MAY CAUSE GASTROINTESTINAL DISCOMFORT. MAY CAUSE
IRRITATION TO RESPIRATORY TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:IRRITATION OF UPPER RESPIRATORY TRACT, SEVERE
IRRITATION OR BURNS TO THE SKIN OR EYES.
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY, SKIN
AND/OR EYE CONDITIONS.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. DRINK WATER.
GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:NONFLAMMABLE. USE EXTINGUISHING MEDIA SUITABLE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR SELF CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:VENTILATE AREA OF SPILL. CLEAN-UP PERSONNEL
SHOULD WEAR PROPER PROTECTIVE EQUIPMENT. AVOID CREATING DUST. SWEEP
OR SCOOP UP AND CONTAINERIZE FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED.
SUITABLE FOR ANY GENERAL CHEMICAL STORAGE AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS. A NIOSH
APPROVED DUST MASK SHOULD BE WORN IF PEL'S ARE EXCEEDED.
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION AS
REQUIRED TO MAINTAIN EXPOSURE LEVELS.
Protective Gloves:RUBBER, NEOPRENE, PVC, OR EQUIVALENT
Eye Protection:SPLASH-PROOF CHEMICAL SAFETY GOGGLES
Other Protective Equipment:LAB COAT. AN EMERGENCY EYEWASH AND SHOWER
SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:4544F,2507C
Melt/Freeze Pt:M.P/F.P Text:449F,232C
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:7.31
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVERY-WHITE GRANULES, POWDER OR SHOT
Percent Volatiles by Volume:NIL

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.