BYSGC - G192
- MSDS: BYSGC
- Manufacturer: DYNAMET INC POWDER PRODUCTS DIV
- Product Name: G192
- National Stock Number: 3439-01-380-2052
Product Identification
Product ID:G192
MSDS Date:02/20/1992
FSC:3439
NIIN:01-380-2052
MSDS Number: BYSGC
Responsible Party
BRIDGEVILLE, PA 15017-2777
US
Emergency Phone: 412-257-5102
Info Phone: 412-257-5102
Preparer: A.J. GREGUS
Cage: 0R811
Contractor
Telephone: 412-257-5102
Cage: 0R811
Ingredients
ALUMINUM
CAS: 7429-90-5
RTECS: BD0330000
Fraction By Weight: 0-3%
ACGIH TLV: 10 MG/M3
BORON
CAS: 7440-42-8
RTECS: ED7350000
Fraction By Weight: 0-2%
OSHA PEL 10 MG B203/M3
ACGIH TLV: 10 MG B2O3/M3
COBALT
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 0-50%
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.1 MG/M3
CHROMIUM
CAS: 7440-47-3
RTECS: GB4200000
Fraction By Weight: 0-25%
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
COPPER
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: 0-1%
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
IRON
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: 0-90%
MANGANESE
CAS: 7439-96-5
RTECS: OO9275000
Fraction By Weight: 0-8%
MOLYBDENUM
CAS: 7439-98-7
RTECS: QA4680000
Fraction By Weight: 0-10%
OSHA PEL 10 PPM.
ACGIH TLV: 10 PPM.
NICKEL
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 0-80%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
VANADIUM PENTOXIDE
CAS: 1314-62-1
RTECS: YW2450000
Fraction By Weight: 0-12%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TANTALUM
CAS: 12070-06-3
Fraction By Weight: 0.20%
OSHA PEL 5 MG TA/M3
ACGIH TLV: 5 MG TA/M3
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 0-5%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:NO TOXIC EFFECTS WOLD BE EXPECTED FROM
ITS INERT SOLID FROM. PROLONGED EXPOSURE TO FUMES OR DUSTS
GENERATED DURING HEATING, CUTTING, BRAZING OR WELDING MAY CAUSE
ADVERSE HEALTH EFFECTS DUE TO SOME OF THE CONSTITUENTS MENTIONED
IN THE FORMULA OR TYPICAL ANALYSIS. SOME CONSTITUENTS POSE MORE
POTENTIAL HAZARDS THAN OTHERS
Explanation of Carcinogenicity:CHROMIUM AND NICKEL AND THEIR COMPOUNDS
ARE LISTED AS CARCINOGENS BY NTP & IARC. SEE INDIVIDUAL REPORTS FOR
DETAILS.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION: INCASE OF OVEREXPOSURE, IMMEDIATELY MOVE PERSON
FROM CONTAMINATED AIR TO FRESH AIR AT ONCE. GIVE ARTIFICAL
RESPIRATION IF BREATHING HAS STOPPED OR OXYGEN IF NECESSARY. GET
MEDICAL ATTENTIO N IF NECESSARY.
Fire Fighting
Extinguishing Media:NO FIRE OR EXPLOSION HAZARDS.
Fire Fighting Procedures:NOT APPLICABLE.
Unusual Fire/Explosion Hazard:NOT APPLICABLE.
Handling
Handling and Storage Precautions:NO SPECIAL HANDLING IS REQUIRED IN ITS
INERT SOLID FORM. DURING WELDING, AIRBORN CONTAMINENTS & NOXIOUS
GASES MAY ORIGIONATE FROM THE WELDING ROD.
Other Precautions:"WE CANNOT COMPREHEND ALL OF THE VARIOUS SITUATIONS
THAT MAY ARISE IN THE USE OF OUR PRODUCTS, THEREFORE OUR CUSTOMERS
ARE RESPONSIVLE FOR ANY HAZARDS AND PRECAUTIONS NOT LISTED ON THIS
MATERIAL SAFET Y DATA SHEET."
Exposure Controls
Respiratory Protection:USE DUST MASK WHEN HANDLING POWDER FORM OF
ALLOY.
Ventilation:USE OF EXHAUST SYSTEMS ARE SUGGESTED FOR ABRASIVE CUTTING,
GRINDING, WELDING, AND BURNING.
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GLASSES OR WELDERS' GOGGLES
Other Protective Equipment:PRECAUTION SHOULD BE TAKEN TO PROTECT
AGAINST BURNS.
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING OR DRINKING
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:5000F,2760C
Spec Gravity:POWDER
Appearance and Odor:ODORLESS SOLID WITH METALLIC LUSTER, AVAILABLE IN
SNEET,STRIP,BAR,ROD,BILLET,ET
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:METAL FUMES AND CERTAIN NOXIOUS GASES
SUCH AS CARBON MONOXIDE, MAY BE PRODUCED DURING WELDING OPERATIONS.
Conditions to Avoid Polymerization:WILL NOT OCCUR
Disposal
Waste Disposal Methods:"NOT APPLICABLE" (IT IS RECOMMENDED THAT ALL
SCRAP GENERATED BE RECLAIMED AND SUBSEQUENTLY RECYCLED.)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.