Product Identification
Product ID:101 3259 LIQUID DEVELOPER SYSTEM CLEANER, CONCENTRATE
MSDS Date:08/02/1995
FSC:6750
NIIN:00D004263
MSDS Number: BYSJM
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 65-70%
SODIUM BICHROMATE (SARA 313) (CERCLA)
CAS: 10588-01-9
RTECS: HX7700000
Fraction By Weight: 18%
OSHA PEL C 0.1 MG (CRO3)/M3
ACGIH TLV: 0.05 MG(CR)/M3;A1;95
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
SULFURIC ACID (SARA 302/313) (CERCLA)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 15-20%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL:HARMFUL. EYE:CAUSES SEVERE
BURNS. SKIN:CAUSES SEVERE BURNS.HARMFUL IF ABSORBED THRU SKIN.MAY
CAUSE ALLERGIC SKIN RX. INGEST:HARMFUL.MAY CAUSE BURNS OF
GASTROINTESTINAL TRACT.CAN CAUSE KIDNEY DMG .
Explanation of Carcinogenicity:PER MSDS:IARC DETERMINED OCCUP EXPO TO
HEXAVALENT CR CMPS & STRONG INORG MIST/VAP W/SULFURIC ACID
CARCINOGENIC TO HUMANS
Effects of Overexposure:SEVERE EYE BURNS, SEVERE SKIN BURNS, ALLERGIC
SKIN REACTION, BURNS OF GASTROINTESTINAL TRACT. KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:SYMPTOMATIC,MOVE TO FRESH AIR.SYMPTOMS PERSISTS GET MED
ATTN. EYE:IMMED FLUSH W/PLENTY OF WATER FOR @LEAST 15MINS.GET MED
ATTN IMMED. SKIN:IMMED FLUSH W/PLENTY OF WATER FOR @LEAST 15MINS
WHILE R EMOVING CONTAMIN CLOTH/SHOES.GET MED ATTN IMMED. INGEST:DO
NOT INDUCE VOMIT.GIVE VICTIM A GLASS OF WATER.NEVER GIVE ANYTHNG BY
MOUTH IF UNCONSC.CALL PHYSICIAN/POIS CNTRL CNTR IMMED.
Fire Fighting
Flash Point:NONE,NON-COMBUST
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTH. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZ
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:SOLUTION CONTAINS A STRONG OXIDIZER.
DRIED PRODUCT RESIDUE CAN ACT AS AN OXIDIZER.
Accidental Release
Spill Release Procedures:ABSORB SPILL W/VERMICULITE OR OTHER INERT
MATL. THEN PLACE IN CNTNR FOR CHEMICAL WASTE. CLEAN SURFACE
THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DON'T BREATH MIST/VAP.DON'T GET IN
EYES/SKIN/CLOTH.USE ONLY W/ADEQUA VENTI.KEEP CNTNR CLSD.KEEP AWAY
FRM INCOMP MATL.
Other Precautions:NOT EXPECTED TO GENERATED MIST/VAP WHEN PROD
ISNTRUCTIONS FOR MIX/USE ARE FOLLOWED.STRONGLY ACIDIC AQU SOLN.NO
BIOCHEM OXY DEMAND,POT TO CAUSAE OXY DEPLETION IN AQU SYS;HIGH POT
TO AFFECT SOME AQUATIC ORG,AFFECT 2ND WSTE TREATMENT (SUPPLEM)
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCEN BEL RECOMMENDED EXPO LIMITS AN APPROVED RESPIARTOR MSUT BE
WRON. RESPIRATOR TYPE:ACID GAS. IF RESP ARE USED PROGRAM SHOULD BE
INSTITUTED TO ASSR UE COMPLIANCE W/OSHA STD 29CFR1910.134.
Ventilation:USE PROCESS ENCLOSURES,LOC EXHAU VENTI,OTHER ENGINEER
CNTRLS TO MAINTAIN AIRBORNE LEVELS BEL RECOMMENDED EXPO LIMITS.
Protective Gloves:NEOPRENE RUBBER (IMPERVIOUS) GLOVES.
Eye Protection:SAF GLASSES W/SIDE SHIELDS,GOGG,FCSHIELD
Other Protective Equipment:PROT CLOTH APPROPRIATE FOR EXPO
RISK.EYEBATH,WASH FACILITIES,SAFETY SHOWER.
Work Hygienic Practices:WASH CONTAMIN CLOTH BEF
REUSE.DESTROY/THOROUHGLY CLEAN CONTAMIN SHOES.WASH THOROUGHLY AFT
HNDLG.
Supplemental Safety and Health
OTHER PRECAUT:MICROBIAL METABOLISM & AFFECT GERMINATION &/OR EARLY
GROWTH OF SOME PLANTS;LOW POT TO BIOCONCEN.AFT DILUT W/LG AMTS OF
WATER & 2ND WASTE TREATMENT MATL NOT EXPECTED TO CAUSE ADVERSE ENVR
IO EFFECTS. SEE SAME NSN PNIND:W FOR WORKING SOLUTION.
Chemical Properties
HCC:C1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18MM @20C
Vapor Density:0.6
Spec Gravity:1.262
pH:<1.0
Solubility in Water:COMPLETE.
Appearance and Odor:LIQUID, ORANGE, SLIGHT ACRID ODOR.
Percent Volatiles by Volume:65-70
Stability
Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS, BASES, COMBUSTIBLE MATERIALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HAZ COMBUST PROD:NONE
(NON-COMBUSTIBLE). HAZ DECOMP PROD:SUFLUR DIOXIDE.
Disposal
Waste Disposal Methods:DISCHARGE/TREAT/DISPO MAY BE SUBJ TO
NATIONAL/STATE/LOC LAWS.CONTRACT W/LICENSED CHEM DISPO AGENCY.SINCE
EMPTIED CNTNRS RETAIN PROD RESIDUE FOLLOW LABEL WARNIGNS EVEN AFT
CNTRN EMPTIED.CHE SUBJ TO SAR A SEC 313 TITLE III REPORTING
REQMT:CR(VI) CMPDS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.