BYSQG - YELLOW ST CA WATERBORNE, 2343A9
- MSDS: BYSQG
- Manufacturer: MORTON INTERNATIONAL
- Product Name: YELLOW ST CA WATERBORNE, 2343A9
- National Stock Number: 8010-00N043433
Product Identification
Product ID:YELLOW ST CA WATERBORNE, 2343A9
MSDS Date:05/03/1993
FSC:8010
NIIN:00N043433
MSDS Number: BYSQG
Responsible Party
LOS ANGELES, CA 90033
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 213-225-4154
Cage: 7D283
Contractor
Telephone: 213-225-4154
Cage: 7D283
Ingredients
1.64 LB/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
BARIUM SULFATE HAS NOT BEEN QUANTIFIED. PERSONS
RTECS: 9999999ZZ
DISEASE MAY BE AT INCR RISK FROM EXPOS. METHANOL
RTECS: 9999999ZZ
HDCH, ANESTH, NEURALOGIC EFTS & VISUAL DIFFICULTIES
RTECS: 9999999ZZ
RESULT IN LIVER & KIDNEY INJURY.
RTECS: 9999999ZZ
TREATMENT
RTECS: 9999999ZZ
ADMINISTERING TO SYMPTOMS AS THEY OCCUR & PROVIDING
RTECS: 9999999ZZ
SUITABLE CNTNR FOR DISP. APPROP SFTY MEASURES &
RTECS: 9999999ZZ
STREAM OR OTHER BODIES OF WATER. COMPLY W/ALL
RTECS: 9999999ZZ
(2) INCIN AT AUTHORIZED FACILITY OR (3)
RTECS: 9999999ZZ
STANDARD 29 CFR 1910.1025 FOR HANDLING LEAD
RTECS: 9999999ZZ
WATER
CAS: 7732-18-5
RTECS: ZC0110000
OSHA PEL N/K
ACGIH TLV: N/K
LEAD SULFOCHROME; (LEAD SULFOCHROMATE)
CAS: 1344-37-2
OSHA PEL N/K
ACGIH TLV: N/K
BARIUM SULFATE
CAS: 7727-43-7
RTECS: CR0600000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
NEPHELINE SYENITE; (NEPHELINE SYENTIE MINEX4)
CAS: 37244-96-5
OSHA PEL N/K
ACGIH TLV: N/K
CALCIUM CARBONATE
CAS: 1317-65-3
RTECS: EV9580000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
ETHYL ALCOHOL (ETHANOL)
CAS: 64-17-5
RTECS: KQ6300000
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
METHYL ALCOHOL (METHANOL) (SARA 313) (CERCLA)
CAS: 67-56-1
RTECS: PC1400000
OSHA PEL 200 PPM, S
ACGIH TLV: 200 PPM; 250 STEL, S
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGEST: GI DISTRESS. SKIN: RPTD/PRLNG
LIQ CNTCT MAY CAUSE IRRIT W/DISCOMFORT & DERM. MAY ALSO CAUSE
ALLERGIC SKIN RXNS. CAN BE ABSORBED THRU SKIN IN HARMFUL AMTS.
INHAL: MAY CAUSE NOSE & THROAT IRRIT. MAY CAUSE NERVOUS SYS
DEPRESS CHARACT BY FOLLOWING PROGRESSIVE STEPS: HDCH, DIZZ, NAUS,
STAG GAIT, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:LEAD SULFOCHROMATE: IARC GROUP 1, SUP
7, P 165, 1987; KNOWN CARCINOGEN NTP 7TH ANN RPT ON CARCINS, 1994.
Effects of Overexposure:HLTH HAZ: CONFUSN, UNCON. REPORTS HAVE ASSOC
RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERVOUS SYS DMG.
CHRONIC: LEAD APPEARS ON NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK
CONSULTATION FROM APPROP HL TH PROFESSIONALS CONCERNING LATEST HAZ
LIST INFO & SAFE HNDLG & EXPOS INFO . LEAD SULFOCCHROMATE; AS (SUP
DAT)
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF CHRONIC
RESPIRATORY, CARDIOVASCULAR OR SKIN DISEASE MAY BE AT AN INCREASED
RISK FROM EXPOSURE TO BARIUM SULFATE.
First Aid
First Aid:INGEST: CALL MD IMMED & HAVE NAMES OF INGREDS AVAIL. SKIN:
CALL MD. IN CASE OF CNTCT, IMMED FLUSH SKIN W/PLENTY OF WATER FOR
AT LEAST 15 MIN WHILE REMOVING CONTAMD CLTHG & SHOES. EYES: IMMED
FLUSH EYE S W/PLENTY OF WATER FOR AT LEAST 15 MIN; CALL MD. IF
IRRIT OCCURS, CNTCT MD. INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG
GIVE ARTF RESP, PREF MOUTH TO MOUTH. IF BRTHG DFCLTY PERSISTS OR
OCCURS (ING 13)
Fire Fighting
Flash Point Method:SCC
Flash Point:106F,41C
Extinguishing Media:USE CHEMICAL FOAM, DRY CHEMICAL OR CARBON DIOXIDE.
ALCOHOL FOAM FOR POLAR SOLVENTS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL
CLOSED CONTAINERS TO PREVENT PRESSURE BUILDUP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH POINT, EMITS
FLAMM VAPS WHICH, WHEN MIXED W/AIR, CAN BURN OR BE EXPLOSIVE. FINE
MISTS/SPRAYS MAY BE FLAMM AT TEMPS BELOW FLASH POINT.
Accidental Release
Spill Release Procedures:STOP DISCHARGE IF IT CAN BE PERFORMED SAFELY &
CONTAIN MATL. IF SUBSTANTIAL QTY IS SPILLED, RECOVER W/PUMP OR
VACUUM TRUCK. EXPLO PROOF EQUIP SHOULD BE USED IF PROD IS FLAMM OR
COMBUST. OTHERWISE, USE SYNTHETIC ABSORB. PLACE CONTAMD MATL IN
(ING 15)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTILATED
AREA. DOL STORAGE CATEGORY: REFERENCE OSHA 1910.106. DO NOT CUT,
GRIND, WELD OR DRILL NEAR THIS CONTAINER.
Other Precautions:CNTNR CAN BE HAZ WHEN EMPTY, BECAUSE IT CAN RETAIN
PROD RESIDUE. THEREFORE, DO NOT REUSE CNTNR FOR FOOD, CLTHG/PRODS
FOR HUMAN/ANIMAL CONSUMPTION OR WHERE SKIN CNTCT MAY OCCUR. ALWAYS
OBEY HAZ WARNING S & HANDLE CNTNRS AS IF THEY WERE FULL.
Exposure Controls
Respiratory Protection:WHEN ESTABLISHED AIRBORNE EXPOSURE LIMITS ARE
SURPASSED, WEAR NIOSH/MSHA APPRVD EQUIPMENT. DETERMINE THE APPROP
TYPE EQUIPMENT FOR SPECIFIC APPLICATION BY CONSULTING RESP MFR.
OBSERVE RESP USE LIMITAT IONS SPECIFIED BY NIOSH/MSHA OR MFR.
Ventilation:LOCAL EXHAUST TO MAINTAIN VAPOR CONCENTRATION BELOW
THRESHOLD LIMIT VALUE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EYE BATH RECOMMENDED.
Work Hygienic Practices:REMOVE AND WASH CONTAMINATED CLOTHING BEFORE
REUSE. DISCARD SHOES IF SATURATED.
Supplemental Safety and Health
EFTS OF OVEREXP: NOTED IN LEAD STD, RPTD & PRLNG EXPOS MAY CAUSE
DELAYED EFTS INVOLVING BLOOD, GI, NERVOUS & REPRO SYS. CHROMIUM &
CERTAIN CHROMIUM CMPDS ARE CURRENTLY CLASSIFIED AS KNOWN CARCINS
BUT IT IS STIPULATED THAT CMPDS RESPONSIBLEFOR CARCIN EFT IN
HUMANS CANNOT BE SPECIFIED. BARIUM SULFATE: TOX OF (ING 9)
Chemical Properties
Vapor Density:HVR/AIR
Spec Gravity:1.553
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:OPAQUE LIQUID WITH AROMATIC SOLVENT ODOR.
Percent Volatiles by Volume:48.68
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS. AVOID CHROMIC ANHYDRIDE, LEAD PERCHLORATE OR
PERCHLORIC ACID.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:MAY LIBERATE CARBON MONOXIDE, CARBON
DIOXIDE AND UNIDENTIFED ORGANIC COMPOUNDS IN BLACK SMOKE.
Disposal
Waste Disposal Methods:DISPOSE OF WASTE I/A/W LOC, STATE & FED REGS. OF
METHS OF DISPOSAL CURRENTLY AVAIL, IT IS RECOM THAT AN ALTERNATIVE
BE SELECTED ACCDG TO FOLLOWING ORDER OF PREFERENCE BASED UPON
ENVIRON ACCEPTABILITY (1) RECYCLE OR REWORK IF AT ALL FEASIBLE,
(ING 17)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.