BYXKR - 802300 SERIES EMERGENCY ESCAPE BREATHING DEVICE

Product Identification

Product ID:802300 SERIES EMERGENCY ESCAPE BREATHING DEVICE
MSDS Date:03/20/1996
FSC:4240
NIIN:01-217-0046
MSDS Number: BYXKR

Responsible Party
SCOTT AVIATION DIV. OF FIGGIE INTL. INC.
225 ERIE ST
LANCASTER, NY 14086
US

Emergency Phone: 716-683-5100

Info Phone: 716-683-5100/FAX 716-681-1089

Cage: 53655

Contractor
SCOTT AVIATION, A FIGG INTERNATIONAL CO, MONROE PL
MONROE, NC 28110-4668 US

Telephone: 716-683-5100

Cage: 15927

Ingredients

SODIUM CHLORATE

CAS: 7775-09-9

RTECS: FO0525000

Fraction By Weight: 85%


POTASSIUM PERCHLORATE

CAS: 7778-74-7

RTECS: SC9700000

Fraction By Weight: 0.5%

OSHA PEL NOT ETABLISHED

ACGIH TLV: 5 MG/M3


BARIUM DIOXIDE (BARIUM PEROXIDE)

CAS: 1304-29-6

RTECS: CR0175000

Fraction By Weight: 4.0%

OSHA PEL 0.5 MG/M3 (BA)

ACGIH TLV: 0.5 MG/M3 (BA); 8990


IRON OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: 3.5%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5MG(FE)/M3FUME,B2;95


MAGNESIUM OXIDE

CAS: 1309-48-4

RTECS: OM3850000

Fraction By Weight: 2.0%

OSHA PEL 15 MG/M3 PARTICULATE

ACGIH TLV: 10 MG/M3; FUME; 9495


MICA - SILICATES (< 1% CRYSTALLINE SILICA)

CAS: 12001-26-2

RTECS: VV8760000

Fraction By Weight: 2.0%

OSHA PEL 20 MPPCF; Z-3

ACGIH TLV: 3 MG/M3 RDUST; 9495


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 2.0%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9495

Hazards

LD50 LC50 Mixture:LETHAL DOSE OF SODIUM CHLORATE = 2-30 GM
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POTENTIAL HEALTH EFFECTS-EYE:MAY CAUSE
LOCAL IRRITATION. SKIN:SODIUM CHLORATE IS MILDLY IRRITATING, MAY
CAUSE RASH. INGESTION:BOTH BARIUM & SODIUM CHLORATE ARE TOXIC.
INHALATION:DUST FROM THE CHEMICAL CORE MAY CAUSE IRRITATION TO THE
MUCOUS MEMBRANES, THROAT & NOSE.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:EYE:LOCAL IRRITATION. SKIN:MILDL IRRITATION,
RASH. INGESTION:BOTH BARIUM & SODIUM CHLORATE ARE TOXIC.
INHALATION:IRRITATION TO THE MUCOUS MEMBRANES, THROAT & NOSE.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION OF MSDS.

First Aid

First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
EYE:FLUSH W/WATER FOR 15 MIN. SKIN:WASH W/SOAP & WATER.
INHALED:AVOID BREATHING EXCESSIVE DUST. REMOVE FROM EXPOSURE AT
ONCE. INGESTED:GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:WATER! OXIDIZERES GENERATE THEIR OWN OXYGEN AS
THEY BURN & CANNOT BE EXTINGUISHED BY MEANS OTHER THAN WATER.
Fire Fighting Procedures:AVOID BODILY CONTACT. WEAR SELF-CONTAINED
BREATHING APPARATUS & PROTECTIVE EQUIPMENT. KEEP MATERIAL FROM
EXPOSURE TO HIGH HEAT BY USING WATER TO COOL & DILUTE.
Unusual Fire/Explosion Hazard:DO NOT USE CO2 OR DRY EXTINGUISHERS AS
THEY ARE INEFFECTIVE & MAY CREATE A WORSE SITUATION.

Accidental Release

Spill Release Procedures:IT IS RECOMMENDED TO VACUUM ALL SPILLAGE W/A
HIGH EFFICIENCY TYPE VAC
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. AVOID
STORING, MIXING, OR CONTAMINATING WITH CHEMICALS, MINERAL ACIDS,
ORGANIC METALS, AND COMBUSTIBLE MATERIALS.
Other Precautions:DO NOT STORE IN WET OR MOIST AREAS.

Exposure Controls

Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES IF HANDLING CORE/DUST.
Eye Protection:NONE SPECIFIED BY MANUFACTURER.
Other Protective Equipment:WEAR IMPERVIOUS GLOVES IF HANDLING THE
CHEMICAL CORE OR DUST FROM THE CHEMICAL CORE. LAUNDER CONTAMINATED
CLOTHING.
Work Hygienic Practices:WASH AFTER HANDLING CORE CHEMICALS OR DUST FROM
CHEMICAL CORE BEFORE EATING, DRINKING, OR SMOKING.
Supplemental Safety and Health
THIS DEVICE IS A SOLID STATE CHEMICAL GENERATOR AND CLASSIFIED AS AN
"ARTICLE" IN 29 CFR 19100.1200(C), AND DOES NOT REQUIRE AN MSDS.
HOWEVER, FOR FEDERAL PROCUREMENT, AN MSDS IS REQUIRED PER APPENDIX
A FEDERAL STANDARD NO. 313, 10.1.3(D) WHICH LISTS OXIDIZERS AS
HAZARDOUS BY DEFINTION IN 49 CFR 173.151.

Chemical Properties

HCC:D1
NRC/State Lic Num:NONE
Spec Gravity:0.92
pH:11.8
Solubility in Water:APPRECIABLE
Appearance and Odor:GREY COMPRESSED GRANULAR FORM W/NO ODOR

Stability

Stability Indicator/Materials to Avoid:YES
OILS, ORGANIC METALS & ACIDS
Stability Condition to Avoid:AVOID STORING, MIXING OR CONTAMINATING
W/CHEMICALS, MINERAL ACIDS & COMBUSTIBLE MATERIALS.
Hazardous Decomposition Products:CAN INCLUDE CHLORINE & CHLORINE
DIOXIDE
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:GENERATORS MUST BE SPENT PRIOR TO DISPOSAL. DUE
TO THE BARIUM WITHIN THE GENERATOR IT IS CONSIDERED A HAZARDOUS
WASTE EVEN AFTER IT IS SPENT. SPENT GENERATOR MUST BE DISPOSED OF
IN ACCORDANCE WITH LOC AL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.