Product Identification
Product ID:ACETONE
MSDS Date:10/01/1995
FSC:6810
NIIN:00F048009
MSDS Number: BZDTN
Responsible Party
MUSKEGON, MI 49442-6101
US
Emergency Phone: 616-726-3171(US)/613-996-6666(CAN)
Info Phone: 616-726-3171
Cage: BAXTE
Contractor
Telephone: 800-368-0050/800-707-4555
Cage: 2H215
Ingredients
ACETONE; DIMETHYL KETONE; 2-PROPANONE
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 100%
OSHA PEL 2400 MG/CUM
ACGIH TLV: 750 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPOSURE CAN CAUSE EYE,
NOSE & THROAT IRRITATION. EYES: IRRITATION. SKIN: CAN CAUSE
IRRITATION & DERMATITIS, CNS DEPRESSANT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, HEADACHE, NAUSEA, DIZZINESS,
NARCOSIS, DEFATTING, DRYNESS, ERYTHMEA, HYPOLGYCEMIA.
Medical Cond Aggravated by Exposure:INDIVIDUALS SUSCEPTABLE TO
DERMATITIS.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE MOUTH TO MOUTH/CPR IF
NEEDED. EYES: RINSE W/COPIOUS AMOUNTS OF WATER FOR 15 MINS. SKIN:
FLUSH THOROUGHLY FOR 15 MINS. WASH W/SOAP & WATER. INGESTION: NEVER
INDUCE VOMITING/GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
PERSON/HAVING CONVULSIONS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:-4F
Lower Limits:2.6
Upper Limits:12.8
Extinguishing Media:CO2, DRY CHEMICAL, ALCOHOL FOAM, WATER MIST/FOG.
Fire Fighting Procedures:WEAR FULLY PROTECTIVE CLOTHING & SCBA. KEEP
FIRE-EXPOSED CONTAINERS COOL W/WATER SPRAY.
Unusual Fire/Explosion Hazard:VERY VOLATILE & EXTREMELY FLAMMABLE;
MIXTURES W/WATER CAN BE FLAMMABLE. HEAT WILL BUILD PRESSURE & MAY
RUPTURE CLOSED STORAGE CONTAINERS.
Accidental Release
Spill Release Procedures:PROTECT FROM IGNITION. WEAR PROTECTIVE
CLOTHING & USE APPROVED RESPIRATOR EQUIPMENT. ABSORB MATERIAL IN AN
ABSORBENT RECOMMENDED FOR SOLVENT & REMOVE TO A SAFE LOCATION FOR
DISPOSAL.
Handling
Handling and Storage Precautions:PROTECT ACETONE FROM TEMP EXTREMES &
DIRECT SUNGLIGHT. STORE ACETONE IN AN ACCEPTABLE PROTECTED & SECURE
FLAMMABLE LIQUID STORAGE ROOM.
Other Precautions:GROUND & BOND METAL CONTAINERS TO MINIMIZE STATIC
SPARKS.
Exposure Controls
Respiratory Protection:USE APPROVED RESPIRATOR EQUIPMENT W/APPROPRIATE
NIOSH EQUIPMENT (AIR-PURIFYING, AIR-SUPPLIED/SCBA).
Ventilation:LOCAL/GENERAL: TO PROTECT PERSONNEL FROM EXPOSURE TO
CHEMICAL VAPORS EXCEEDING THE PEL & TO MINIMIZE FIRE HAZARDS.
Protective Gloves:NEOPRENE/RUBBER
Eye Protection:SAFETY GLASSES/GOGGLES/FACE SHIELD
Other Protective Equipment:PROTECTIVE CLOTHING & EQUIPMENT, EMERGENCY
EYEWASH FOUNTAINS & SAFETY SHOWERS.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:133.32F
Melt/Freeze Pt:M.P/F.P Text:-138.46F
Vapor Pres:184.5
Vapor Density:2
Spec Gravity:0.79
Evaporation Rate & Reference:(BU AC = 1): 12
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID W/A PENETRATING SWEET ODOR
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS, BASES.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME, EXTREME TEMPS,
DIRECT SUNLIGHT.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION: CO & OTHER
TOXIC VAPORS.
Disposal
Waste Disposal Methods:DISPOSE OF ACETONE AS AN EPA HAZARDOUS WASTE
IAW/FEDERAL, STATE & LOCAL REGULATIONS. HAZARDOUS WASTE NO: U003,
IGNITABLE: D001. FLAMMABLE LIQUID, UN1090.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.