BZPFL - DRY CHARGED BATTERY (NO ELECTROLYTE ADDED),MFD-70,9107 DE
- MSDS: BZPFL
- Manufacturer: EXIDE CORP GENERAL BATTERY CORP
- Product Name: DRY CHARGED BATTERY (NO ELECTROLYTE ADDED),MFD-70,9107 DE
- National Stock Number: 6140-00-184-3415
Product Identification
Product ID:DRY CHARGED BATTERY (NO ELECTROLYTE ADDED),MFD-70,9107 DE
MSDS Date:04/01/1996
FSC:6140
NIIN:00-184-3415
MSDS Number: BZPFL
Responsible Party
READING, PA 19601
US
Emergency Phone: 215-378-0527/800-424-9300(CHEMTREC)
Info Phone: 215-378-0527/610-378-0500
Cage: 08163
Contractor
Telephone: 215-378-0527/800-424-9300(CHEMTREC)
Cage: 08163
Ingredients
LEAD (SARA 313) (CERCLA); TOTAL PERCENTAGE OF INGREDIENTS
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: SEE ING
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.15MG/M3 DUST; 9495
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
LEAD OXIDE (LITHARGE)
CAS: 1317-36-8
RTECS: OG1750000
Fraction By Weight: SEE # 1%
LEAD SULFATE (SARA 313) (CERCLA)
CAS: 7446-14-2
RTECS: OG4375000
Fraction By Weight: SEE # 1%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.15 MG(PB)/M3; 9495
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
ANTIMONY (SARA 313) (CERCLA)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: 0.2%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9495
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA 313) (CERCLA)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: 0.003%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.01 MG/M3, A1; 9495
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
CALCIUM, METAL
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: 0.02%
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 0.06%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9495
CASE MATERIAL (POLYPROPYLENE, 9003-07-0 AND HARD RUBBER)
Fraction By Weight: 6 - 8%
Hazards
LD50 LC50 Mixture:NOT RELEVANT
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:NONE. ACUTE- PRODUCT IS
A DRY CHARGED BATTERY. NO HAZARD IS ANTICIPATED. HAZARDOUS EXPOSURE
CAN OCCUR WHEN PRODUCT IS IN FIRE/BROKEN: LEAD COMPOUNDS MAY CAUSE
EYE & RESPIRATORY IRRITATIO N. TOXIC IF INGESTED. CHRONIC- LEAD
COMPOUNDS MAY CAUSE ANEMIA, KIDNEY DAMAGE, NERVE DAMAGE (WRIST
DROP).
Explanation of Carcinogenicity:CONTAINS LEAD. ARSENIC IS LESS THAN 0.10
%.
Effects of Overexposure:NONE. IF IN FIRE OR BROKEN, DUST OR FUMES MAY
CAUSE: IRRITATION, ANEMIA, ABDOMINAL PAIN, NAUSEA, VOMITING,
CONSTIPATION, HEADACHE, FATIGUE, LOSS OF APPETITE, MUSCULAR ACHES
AND WEAKNESS, SLEEP DISTURB ANCES
Medical Cond Aggravated by Exposure:LEAD AND ITS COMPONENTS CAN
AGGRAVATE SOME FORMS OF KIDNEY, LIVER AND NEUROLOGIC DISEASES.
First Aid
First Aid:INHALATION - LEAD: REMOVE FROM EXPOSURE, GARGLE, WASH NOSE
AND LIPS; CONSULT PHYSICIAN. INGESTION - LEAD: CONSULT PHYSICIAN
IMMEDIATELY. SKIN - LEAD: WASH IMMEDIATELY WITH SOAP AND WATER.
EYES - LEAD: FLUSH IMMEDIATELY WITH LARGE AMOUNT OFWATER FOR AT
LEAST 15 MINUTES; CONSULT PHYSICIAN.
Fire Fighting
Flash Point:NOT RELEVANT
Lower Limits:4.1%HYDROGEN
Upper Limits:74.2% (H2)
Extinguishing Media:BATTERY CASE WILL BURN. USE CARBON DIOXIDE,
FOAM/DRY CHEMICAL EXTINGUISHER. WATER MAY CAUSE SPATTERING OF
MOLTEN LEAD.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND
NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH FULL
FACEPIECE OPERATED IN POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:MOLTEN METALS PRODUCE FUMES, VAPORS
AND/OR DUST THAT MAY BE TOXIC AND/OR RESPIRATORY IRRITANTS.
Accidental Release
Spill Release Procedures:IF BROKEN, LEAD DUST OR PARTICULATE SHOULD BE
VACUUMED (USING HEPA FILTER) OR WET-SWEPT. DO NOT DRY SWEEP OR USE
FORCED AIR. PLACE IN DRY, CLOSED CONTAINER FOR DISPOSAL OR
RECYCLING.
Neutralizing Agent:NOT RELEVANT
Handling
Handling and Storage Precautions:STORE BATTERIES IN COOL, DRY,
WELL-VENTILATED AREAS, UNDER THE ROOF. SEPARATE FROM INCOMPATIBLE
MATERIALS. KEEP AWAY FROM HEAT, SPARKS AND FIRE.
Other Precautions:WASH HANDS BEFORE EATING OR DRINKING. KEEP OUT OF
REACH OF CHILDREN. AVOID THE USE OF UNINSULATED TOOLS. DO NOT MAKE
A CONNECTION BETWEEN THE TWO BATTERY TERMINALS AS SEVERE SPARKING
MAY OCCUR WHICH C OULD RESULT IN AN EXPLOSION.
Exposure Controls
Respiratory Protection:NONE REQUIRED. FOR DUST, FUME OR MIST, WEAR
NIOSH-APPROVED RESPIRATOR OR SELF-CONTAINED BREATHING APPARATUS.
Ventilation:ADEQUATE
Protective Gloves:RUBBER GLOVES WHEN FILLING BATTERIES
Eye Protection:CHEMICAL GOGGLES WHEN FILLING BATTERIES
Other Protective Equipment:EYE WASH STATION, EMERGENCY SHOWER, COVERALL
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
FORMULA CHANGED. FOR PREVIOUS FORMULATIONS, SEE PNI A OR B, SAME NSN.
Chemical Properties
HCC:N1
NRC/State Lic Num:NOT RELEVANT
Decomp Temp:Decomp Text:NOT KNOWN
Spec Gravity:NOT RELEVANT
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NOT RELEVANT
Appearance and Odor:PRODUCT IS A DRY CHARGED BATTERY.
Stability
Stability Indicator/Materials to Avoid:YES
LEAD COMPOUNDS: STRONG ACIDS, STRONG ALKALIS, HALIDES, HALOGENATES,
POTASSIUM NITRATE, REDUCING AGENTS
Stability Condition to Avoid:PROLONGED OVERCHARGE, SOURCES OF IGNITION,
WATER
Hazardous Decomposition Products:TOXIC METAL FUMES, VAPOR OR DUST,
TOXIC ARSINE GAS
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS. MATERIAL SHOULD BE RECYCLED AT A SECONDARY
LEAD SMELTER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.