Product Identification

Product ID:PUROGENE
MSDS Date:06/01/1994
FSC:6850
NIIN:00F048844
MSDS Number: BZTZB

Responsible Party
BIOCIDE INTERNATIONAL INC
2845 BROCE DR
NORMAN, OK 73070-5000
US

Emergency Phone: 405-329-5556 (24 HRS)

Info Phone: 405-329-5556 (24 HRS)

Cage: 0CKJ1

Contractor
BIOCIDE INTERNATIONAL INC
722170 NORMAN, OK 73070-5000 US

Telephone: 405-329-5556 (24 HRS)

Cage: 0CKJ1

Ingredients

SODIUM CHLORITE

CAS: 7758-19-2

RTECS: VZ4800000

Fraction By Weight: <3.35%


CHLORINE DIOXIDE

CAS: 10049-04-4

RTECS: FO3000000

OSHA PEL 0.1 PPM

ACGIH TLV: 0.1 PPM

Hazards

LD50 LC50 Mixture:ORAL LD50(RAT): 4,360 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY PRODUCE
METHEMOGLOBINEMIA. EYES: SLIGHT IRRITATION OF CONJUNCTIVA, CORNEA &
EYELID. SKIN: PROLONGED EXPOSURE MAY PRODUCE LOCALIZED IRRITATION,
DERMATITIS, MILD ERYTHEMA & EDEMA. INHALAT ION: MAY BE IRRITATING
TO NOSE & THROAT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:GASTRIC DISCOMFORT, NAUSEA, VOMITING, DIARRHEA,
IRRITATION.
Medical Cond Aggravated by Exposure:SKIN DISORDERS, DERMAL ALLERGIES &
DERMATITIS. CHLORINE DIOXDE: PULMONARY DISORDERS, EMPHYSEMA.

First Aid

First Aid:SKIN: WASH AREA THOROUGHLY W/SOAP & WATER. EYES: FLUSH
THOROUGHLY W/WATER. INHALATION: REMOVE TO FRESH AIR. INGESTION:
DON'T INDUCE VOMITING. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point:NONE TO BOILING
Extinguishing Media:WATER
Fire Fighting Procedures:STANDARD PROTECTIVE GEAR W/SCBA. DON'T ALLOW
PUROGENE SOLUTIONS EVAPORATE TO DRYNESS. IF CHLORINE DIOXIDE GAS IS
PRODUCED, VENT TO ATMOSPHERE. (SEE SUPP)
Unusual Fire/Explosion Hazard:SODIUM CHLORITE SUPPORTS COMBUSTION.
CHLORINE DIOXIDE IS EXPLOSIVE IN GASEOUS PHASE AT CONCENTRATIONS
>10%. DON'T ALLOW CHLORINE DIOXIDE GAS TO ACCUMULATE.

Accidental Release

Spill Release Procedures:SMALL: INVOLVING <10 GALLONS, FLUSH TO A
DESIGNATED & PERMITTED SEWER SYSTEM W/COPIOUS AMOUNTS OF WATER.
LARGE: CONTAIN & NEUTRALIZE W/SODIUM BISULFITE/SODIUM
THIOSULFATE/DISPOSE OF AS CHEMICAL WASTE. THOROUGHLY FLUSH W/WATER
AFTER CLEANUP. (SUPP)

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA AWAY FROM ORGANIC MATERIALS & DIRECT SUNLIGHT. KEEP CONTAINERS
TIGHTLY CLOSED WHEN NOT IN USE.
Other Precautions:OPEN CAREFULLY TO PREVENT SPILLAGE. DON'T STORE ON
WOODEN FLOORS & PALLETS. AVOID CONTACT W/SKIN, EYES & BREATHING
VAPORS/FUMES. KEEP AWAY FROM CHILDREN, ANIMALS & UNAUTHORIZED
PERSONNEL. THOROUGHLY R INSE PROTECT GEAR & HANDLING EQUIPMENT.

Exposure Controls

Respiratory Protection:FOGGING/SPRAYING APPLICATIONS MAY REQUIRE
RESPIRATORY PROTECTION, USE A NIOSH/MSHA APPROVED AIR PURIFYING
RESPIRATORS/NIOSH/MSHA APPROVED CANISTER/CARTRIDGE FACIAL
RESPIRATORS.
Ventilation:OPEN AIR/GOOD ROOM.
Protective Gloves:RUBBER/NEOPRENE/CHEMICALLY IMPERVIOUS
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:SAFETY SHOWER, CHEMICAL EYEWASH
STATION/OTHER FRESH WATER SOURCE.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE/DISCARDIG. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PH CONCENTRATE: 8-8.5. FIRE PROC CONT'D: OPEN/VENT ANY LARGE CONTAINERS
OF PUROGENE. SPILLS CONT'D: DON'T ALLOW MATERIAL TO DRY TO A
CRYSTALLINE SALT. DON'T DISCHARGE PRODUCT TO STORM DRAINS/ANY SURFA
CE/GROUNDWATER SOURCE. PRECAUTIONS: PRODUCT MAY BLEACH CLOTHING &
FABRIC MATERIALS, SUCH AS DRAPERIES & CARPETS.

Chemical Properties

Boiling Pt:B.P. Text:213F
Vapor Pres:23.7
Vapor Density:0.02
Spec Gravity:1.03
pH:(SUPP)
Evaporation Rate & Reference:(WATER = 1): 1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR LIQUID W/VERY FAINT CHLORINOUS ODOR
Percent Volatiles by Volume:97

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS/CHLORINE COMPOUNDS/HYPOCHLORITES(BLEACH)/SULFUR & SULFITE
COMPOUNDS/PHOSPHORUS/ORGANIC SOLVENTS & OTHER MATERIALS.
Stability Condition to Avoid:EVAPORATION
Hazardous Decomposition Products:CHLORINE DIOXIDE GAS

Disposal

Waste Disposal Methods:SMALL QUANTITIES <10 GALLONS SHOULD BE FLUSHED
TO AN AUTHORIZED & PERMITTED SEWER W/COPIOUS AMOUNTS OF WATER.
LARGE: DISPOSE TO AN AUTHORIZED CHEMICAL DISPOSAL SITE/LANDFILL
IAW/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.