BZWDQ - FRIGC FR-12

Product Identification

Product ID:FRIGC FR-12
MSDS Date:04/21/1995
FSC:6830
NIIN:00F049555
MSDS Number: BZWDQ

Responsible Party
INTERMAGNETICS GENERAL CORPORATION
1833 VULTEE STREET
ALLENTOWN, PA 18103-5000
US

Emergency Phone: 610-791-6700

Info Phone: 800-525-3071

Cage: 040E1

Contractor
INTERCOOL ENERGY CORP/INTERMAGNETICS GENERAL CORPORATION
461 LATHAM, NY 12110-0461 US

Telephone: 412-782-7749

Cage: 040E1

Ingredients

1,1,1,2-TETRAFLUOROETHANE (R134A)

CAS: 811-97-2


BUTANE, N-BUTANE

CAS: 106-97-8

RTECS: EJ4200000

OSHA PEL 800 PPM

ACGIH TLV: 1900 MG/CUM


2-CHLORO-1,1,2-TETRAFLUOROETHANE

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NON-TOXIC & ACTS AS A SIMPLE
ASPHYXIANT, MAY HAVE AN ANESTHETIC PROPERTY WHEN EXPOSED TO
CONCENTRATIONS >1%. DEATH.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:RAPID RESPIRATION, AIR HUNGER, INCOORDINATION,
FATIGUE, NAUSEA, VOMITING, CONVULSIONS, LOSS OF CONSCIOUSNESS,
DIZZINESS.

First Aid

First Aid:EYES: LIQUID-GENTLY FLUSH W/LUKEWARM WATER. SKIN:
LIQUID-FLUSH W/LUKEWARM WATER & TREAT FOR FROSTBITE. DON'T USE HOT
WATER. INHALATION: IF CONSCIOUS, REMOVE TO FRESH AIR. IF
UNCONSCIOUS, MOVE TO UNCON TAMINATED AREA, GIVE MOUTH TO MOUTH &
OXYGEN. DON'T GIVE EPINEPHRINE (ADRENALINE). INGESTION: DON'T
INDUCE VOMITING. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:DRY CHEMICAL, CO2, HALON
Fire Fighting Procedures:IF POSSIBLE, STOP FLOW OF GAS/VAPOR/SHUT OFF
FLOW SAFELY. ALLOW FIRE TO BURN ITSELF OUT. COOL CYLINDERS W/WATER
SPRAY.
Unusual Fire/Explosion Hazard:CONTACT W/CERTAIN REACTIVE METALS MAY
RESULT IN FORMATION OF EXPLOSIVE/EXOTHERMIC REACTIONS. EXPOSURE TO
HEAT/FLAME MAY VENT RAPIDLY/EXLODE.

Accidental Release

Spill Release Procedures:EVACUATE AREA. USE APPROPRIATE PROTECTIVE
EQUIPMENT. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN PURGE PIPING
W/AN INERT GAS PRIOR TO ATTEMPTING REPAIRS.

Handling

Handling and Storage Precautions:NEVER EXPOSE TO EXCESSIVE HEAT.
CYLINDERS SHOULD BE STORED IN A WELL VENTILATED AREA. STORAGE
SHOULDN'T EXCEED 122F. DON'T DRAG/ROLL/SLIDE CYLINDERS.
Other Precautions:SECURE CYLINDERS AT ALL TIMES. USE SEPARATE CONTROL
VALVES/PRESSURE REDUCING REGULATORS TO SAFELY DISCHARGE GAS FROM
CYLINDER. USEA CHECK VALVE TO PREVENT REVERSE FLOW INTO CYLINDER/AN
INCREASE IN PRE SSURE/AN INCREASED DISCHARGED RATE.(SUPP

Exposure Controls

Respiratory Protection:USE POSITIVE PRESSURE AIR LINE W/MASK/SCBA
SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:FUME HOOD W/FORCED VENTILATION &/LOCAL EXHAUST
Protective Gloves:PLASTIC/RUBBER
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:SAFETY SHOES.
Supplemental Safety and Health
COMPRESSED GAS CYLINDERS SHOULDN'T BE REFILLED EXCEPT BY A QUALIFIED
PRODUCER OF THE GAS. SHIPMENT OF THE COMPRESSED GAS CYLINDER WHICH
HASN'T BEEN FILLED BY THE OWNER/W/THE OWNERS CONSENT IS A VIOLAT
ION OF FEDERAL LAW.

Chemical Properties

Boiling Pt:B.P. Text:-11.56F
Melt/Freeze Pt:M.P/F.P Text:-149.8F
Vapor Pres:4620
Solubility in Water:1.4 G/L
Appearance and Odor:CLEAR; COLORLESS GAS W/FAINT HYDROCARBON ODOR
(SHIPPED AS LIQUEFIED GAS)

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:TEMPS >122F, EXTREME HEAT

Disposal

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS. NONFLAMMABLE GAS, UN1078.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.