CBBLK - ULTRA HI-WEAR/HI-GLOSS FINISH

  • MSDS: CBBLK
  • Manufacturer: MISCO PRODUCTS CORP
  • Product Name: ULTRA HI-WEAR/HI-GLOSS FINISH
  • National Stock Number: 8010-00N023302
Product Identification

Product ID:ULTRA HI-WEAR/HI-GLOSS FINISH
MSDS Date:01/01/1991
FSC:8010
NIIN:00N023302
MSDS Number: CBBLK

Responsible Party
MISCO PRODUCTS CORP
RD 9
READING, PA 19605
US

Emergency Phone: 215-926-4106

Info Phone: 215-926-4106

Cage: MISCO

Contractor
MISCO PRODUCTS CORPORATION
9155 READING, PA 19605 US

Telephone: 215-926-4106

Cage: MISCO

Ingredients

STYRENE, BUTYL ACRYLATE, ETHYL ACRYLATE, METHYL

CAS: 63744-68-3

Fraction By Weight: 45-50%

OSHA PEL N/K

ACGIH TLV: N/K


RESIN SOLUTION

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


POLYETHYLENE WAX (EMULSION)

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


1); (TRIBUTOXY ETHYL

CAS: 78-51-3

RTECS: KJ9800000

Fraction By Weight: 0-5%

OSHA PEL N/K

ACGIH TLV: N/K


ETHANOL, 2-(2-METHOXYETHOXY)-; (DIETHYLENE GLYCOL

CAS: 111-77-3

RTECS: KL6125000

Fraction By Weight: 0-5%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: <100%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN:PROLONGED OR REPEATED CONTACT MAY
CAUSE DERMATITIS. EYES:IRRITANT. MAY CAUSE REDNESS OR SWELLING.
INGESTION:MAY BE IRRITATING TO THE MOUTH, THROAT & GASTROINTESTINAL
SYSTEM. VOMITING & DIARRHEA E XPECTED W/LARGE DOSES.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . SKIN:FLUSH W/WATER. SEEK MEDICAL ATTENTION IF IRRITATION
PERSISTS. EYES:FLUSH W/LARGE QUANTITIES OF WATER FOR AT LEAST 15
MINU TES, HOLDING EYELIDS OPEN. SEEK MEDICALATTENTION.
INGEST:DILUTE W/2 GLASSES OF WATER. SEEK MEDICAL ATTENTION &
SYMPTOMS PERSIST.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NON-FLAMMABLE.

Accidental Release

Spill Release Procedures:MOP UP OR OTHERWISE ABSORB & HOLD FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. FOR USE
BY TRAINED PERSONNEL ONLY. KEEP CONTAINER CLOSED DURING STORAGE.
FOR INSTITUTIONAL & INDUSTRIAL USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NO SPECIAL REQUIREMENTS.
Ventilation:PROVIDE LOCAL EXHAUST TO KEEP TLV BELOW ACCEPTABLE LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:20 @ 68F
Vapor Density:>1
Spec Gravity:1.03
pH:8.5-9
Evaporation Rate & Reference:<1 (WATER=1)
Solubility in Water:COMPLETE
Appearance and Odor:THIN MILKY LIQUID W/CHARACTERISTIC ODOR.
Percent Volatiles by Volume:>75

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . ANY METHOD I/A/W APPLICABLE LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.