CBCVQ - AIR, COMPRESSED

  • MSDS: CBCVQ
  • Manufacturer: AIRGAS
  • Product Name: AIR, COMPRESSED
  • National Stock Number: 6830-00N065335
Product Identification

Product ID:AIR, COMPRESSED
MSDS Date:05/01/1990
FSC:6830
NIIN:00N065335
MSDS Number: CBCVQ

Responsible Party
AIRGAS
100 MATSONFORD RD
RADNOR, PA 19067
US

Emergency Phone: 215-687-5253

Info Phone: 215-687-5253

Cage: AIRGA

Contractor
AIRGAS INC
WAYNE, PA 19087 US

Telephone: 215-687-5253

Cage: 0MN39

Ingredients

AIR, COMPRESSED

CAS: 25635-88-5

OSHA PEL N/K

ACGIH TLV: N/K


DECOMPRESSION EQUIPMENT MAY BE REQUIRED.

RTECS: 9999999ZZ


TELEPHONE NUMBER LISTED.

RTECS: 9999999ZZ


USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT

RTECS: 9999999ZZ


STORE IN COOL, DRY, WELL-VENTILATED AREA AWAY FROM

RTECS: 9999999ZZ


WHERE CYLS ARE STORED TO EXCEED 130F (54C). CYLS

RTECS: 9999999ZZ


BEING KNOCKED OVER. FULL & EMPTY CYLS SHOULD BE

RTECS: 9999999ZZ


FULL CYLS BEING STORED FOR EXCESSIVE PERIODS OF TIME.

RTECS: 9999999ZZ


ASSOC'S PAMPHLETS P-1, P-9, P-14 & SAFETY BULLETIN

RTECS: 9999999ZZ


COMMON STRUCTURAL MATLS. COMPRESSED GAS CYLS SHOULD

RTECS: 9999999ZZ


COMPRESSED GASES. SHIPMENT OF COMPRESSED GAS CYL

RTECS: 9999999ZZ


CONSENT IS VIOLATION OF FED LAW (49 CFR). ALWAYS

RTECS: 9999999ZZ


THEM. NEVER TRANSPORT CYLS IN TRUNKS OF VEHICLES,

RTECS: 9999999ZZ


TRANSPORT CYLINDERS SECURED IN OPEN FLATBED OR IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:AIR IS NONTOX & NEC TO SUPPORT
LIFE. INHAL OF AIR IN HIGH PRESS ENVIRON SUCH AS UNDERWATER DIVING,
CAISSONS/HYPERBARIC CHAMBERS CAN RSLT IN SYMPS SIMILAR TO OVEREXP
TO PURE OXYG. THESE INCL TING LING OF FINGERS & TOES, ABNORM
SENSATIONS, IMPAIRED COORD & CONFUSN. DECOMPRESSION SICKNESS,
PAINS/ (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:"BENDS" ARE POSS FOLLOWING RAPID
DECOMPRESSION. HIGH PRESS EFTS (>2 ATMS OF OXYG) ARE ON CNS.
IMPROPER DECOMPRESSION RSLTS IN ACCUM OF NITROGEN IN BLOOD. SYMPS
OF EXPOS:TINGLING OF TONGUE, FI NGERTIPS/TOES; WEAKENED SPEECH
LEADING TO INABILITY TO UTTER SOUNDS; RAPID REDUCTION IN ABILITY TO
PERFORM (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMED . INHAL:REMOVE TO FRESH AIR. SUPPORT
BRTHG (GIVE O*2/ARTF RESP) . EYES:IMMED FLUSH W/POTABLE WATER FOR
MIN OF 15 MINS, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COP IOUS
AMTS OF WATER. CALL MD . FACILITIES/PRACTICES AT WHICH AIR IS
BREATHED IN HIGH PRESS ENVIRON SHOULD BE PREPARED TO DEAL
W/ILLNESSES ASSOC W/DECOMPRESSION (BENDS/CAISSON DISEASE). (ING 2)

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . NONFLAMMABLE,
INERT GAS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . IF CYLINDERS ARE INVOLVED IN A FIRE, SAFELY RELOCATE OR
KEEP COOL W/WATER SPRAY.

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE
APPROPRIATE PROTECTIVE EQUIPMENT. IF LEAK IS IN CONTAINER OR
CONTAINER VALVE, CONTACT YOUR CLOSEST SUPPLIER LOCATION OR CALL
EMERGENCY TELEPHONE NUMBER L ISTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY IN WELL-VENTILATED AREAS.
VALVE PROT CAPS MUST REMAIN IN PLACE UNLESS CYL IS SECURED W/VALVE
OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK
FOR CYL MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL
TO LOWER PRESS (<3,000 PSIG) PIPING/SYS. DO NOT HEAT CYL BY ANY
MEANS TO INCR D ISCHARGE RATE OF PROD FROM CYL. (ING 4)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE AIR LINE W/MASK OR
SELF-CONTAINED BREATHING APPARATUS SHOULD BE AVAILABLE FOR
EMERGENCY USE.
Ventilation:LOCAL EXHAUST:TO PREVENT ACCUMULATION OF HIGH
CONCENTRATIONS SO AS TO REDUCE OXYGEN LEVEL IN AIR TO >18 MOLAR
PERCENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:ABOVE CRITICAL TEMP OF -232.6F (-147C). EFTS OF OVEREXP:MOVEMENTS;
REDUCED CONSCIOUSNESS OF SURROUNDS; LOSS OF TACTILE SENSATIONS;
HEIGHTENED MENTAL ACTIVITY. IT SHOULD BE RECOGNIZED THAT IT IS POS
S THAT NONE OF ABOVE SYMPS MAY OCCUR INGAS ASPHYXIA SO THAT THERE
ARE NO DEFINITE WARNING SYMPTOMS.

Chemical Properties

Boiling Pt:B.P. Text:-321F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Pres:SUPP DATA
Spec Gravity:0.97 (AIR=1)
Solubility in Water:VERY SLIGHTLY
Appearance and Odor:COLORLESS, ODORLESS GAS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS.
RETURN IN SHIPPING CNTNR PROPERLY LABELED, W/VALVE OUTLET
PLUGS/CAPS SECURED & VALVE PROT CAP IN PLACE TO YOUR SUPPLIER. FOR
EMER HOSPITAL ASSISTANCE, CONT YOUR CLOSEST SUPPLIER LOCATION/CALL
EMER (ING 3)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.