CBFYP - POTASSIUM BROMIDE, I-92

  • MSDS: CBFYP
  • Manufacturer: CHEM SERVICE INC
  • Product Name: POTASSIUM BROMIDE, I-92
  • National Stock Number: 6810-00N067496
Product Identification

Product ID:POTASSIUM BROMIDE, I-92
MSDS Date:09/01/1988
FSC:6810
NIIN:00N067496
MSDS Number: CBFYP

Responsible Party
CHEM SERVICE INC
WEST CHESTER, PA 19381
US

Emergency Phone: 215-692-3026

Info Phone: 215-692-3026

Cage: 84898

Contractor
CHEM SERVICE, INC
599 WEST CHESTER, PA 19301-9650 US

Telephone: 610-692-3026

Cage: 8Y898

Ingredients

POTASSIUM BROMIDE

CAS: 7758-02-3

RTECS: TS7650000

OSHA PEL N/K

ACGIH TLV: N/K


REMOVE & WASH CONTAMD CLTHG. DO NOT WEAR SHOES/CLTHG

RTECS: 9999999ZZ


LIQ/INDUCE VOMIT TO UNCON/CONVULS PERSON. IF

RTECS: 9999999ZZ


IF NEC. GET MED ATTN IF NEC. IF PATIENT IS

RTECS: 9999999ZZ


OBSTRUCTED BY VOMIT.

RTECS: 9999999ZZ


FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT LENSES SHOULD NOT BE WORN IN
LABORATORY. ALL CHEMICALS SHOULD BE CONSIDERED HAZ-AVOID DIRECT
PHYSICAL CONTACT! CAN CAUSE EYE IRRITATION. CAN CAUSE SKIN
IRRITATION. CAN BE HARMFUL IF ABSORBED T HROUGH SKIN. REPEATED
EXPOSURE TO VAPORS AND/OR DUST CAN CAUSE EYE INJURY. CAN BE HARMFUL
IF INHALED. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DUST AND/OR VAPORS CAN CAUSE
IRRITATION TO RESPIRATORY TRACT. CAN CAUSE CHLORACNE. CAN BE
HARMFUL IF SWALLOWED. CAN CAUSE NERVOUS SYSTEM INJURY. CAN CAUSE
GASTRO-INTESTINAL DISTURBANCES. NARC OTIC @ HIGH CONC.
TOXICITY:ASSUM THIS CHEM IS TOXIC & USE SPECIAL CARE TO AVOID
CONTACT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:AN ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF A
POISON. IT SHOULD BE ADMIN ONLY BY PHYS/TRAINED EMER PERS. MED
ADVICE CAN BE OBTAINED FROM POIS CTL CTR. EYES:FLUSH CONTINUOUSLY
W/WATER FOR @ LEAST 15 MINS. SKIN:FLUSH W/WATER FOR 15-20 MINS. IF
NO BURNS HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN.
INHAL:REMOVE PATIENT TO FRESH AIR. ADMIN OXYG IF PATIENT IS HAVING
DFCLTY BRTHG. (SUPDAT)

Fire Fighting

Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:EVACUATE AREA. WEAR APPROP OSHA-REGULATED
EQUIP. VENTILATE AREA. SWEEP UP & PLACE IN APPROP CNTNR. HOLD FOR
DISPOSAL. WASH CONTAMINATED SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE APPROP NIOSH/MSHA APPRVD SFTY
EQUIP. AVOID CONT W/SKIN, EYES & CLTHG. KEEP TIGHTLY CLSD & STORE
IN COOL DRY PLACE. STORE ONLY W/COMPAT CHEMICALS.
Other Precautions:THIS PRODUCT IS FURNISHED FOR LABORATORY USE ONLY!
PRODUCTS MAY NOT BE USED AS DRUGS, COSMETICS, AGRICULTURAL OR
PESTICIDAL PRODUCTS, FOOD ADDITIVES OR AS HOUSEHOLD CHEMICALS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG & (ING 6)
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
CNDTNS TO AVOID:OR THEIR ALLOYS AS CNTNRS. CORRODES STEEL. FIRST AID
PROC:IF PATIENT HAS STOPPED BRTHG ADMIN ARTF RESP. IF PATIENT IS
EXHIBITING SIGNS OF SHOCK-KEEP WARM & QUIET. GET MED ATTN IF NEC.
IF PATIENT IS IN CARD ARREST ADMIN CPR.CONTINUE LIFE SUPPORTING
MEASURES UNTIL MED ASSISTANCE HAS ARRIVED. (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:2615F,1435C
Melt/Freeze Pt:M.P/F.P Text:8553F,4734C
Spec Gravity:2.75
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS CRYSTALLINE SOLID.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:EASILY OXIDIZED-MAY BE PEROXIDE
FORMER-CHECK FOR PEROXIDES ON ALL OPENED SAMPLES. DO NOT USE
MAGNESIUM/ALUMINUM (SUPDAT)
Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES.
DECOMPOSITION PRODUCTS ARE CORROSIVE. DECOMPOSED BY CHLORINE GAS.

Disposal

Waste Disposal Methods:FLUSH TO SEWER WITH COPIOUS AMOUNTS OF WATER.
DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.