CBGND - (DICHLOROMETHYL)BENZENE, O-680

  • MSDS: CBGND
  • Manufacturer: CHEM SERVICE INC
  • Product Name: (DICHLOROMETHYL)BENZENE, O-680
  • National Stock Number: 6810-00N067809
Product Identification

Product ID:(DICHLOROMETHYL)BENZENE, O-680
MSDS Date:09/01/1988
FSC:6810
NIIN:00N067809
MSDS Number: CBGND

Responsible Party
CHEM SERVICE INC
WEST CHESTER, PA 19381
US

Emergency Phone: 215-692-3026

Info Phone: 215-692-3026

Cage: 84898

Contractor
CHEM SERVICE, INC
599 WEST CHESTER, PA 19301-9650 US

Telephone: 610-692-3026

Cage: 8Y898

Ingredients

BENZENE, (DICHLOROMETHYL)-; ((DICHLOROMETHYL)BENZENE) (SARA

CAS: 98-87-3

RTECS: CZ5075000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50: (RAT) 3249 MG/K3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS - AVOID DIRECT PHYSICAL CONTACT! LACHRYMATOR-CAUSES
SEVERE EYE IRRITATION. CAN CAUSE SKIN IRRITATION. CAN CAUSE AN
ALLERGIC SKIN REACTION. CAN CAUSE AN ALL ERGIC RESPIRATORY
REACTION. CAN CAUSE EYE IRRITATION. CAN BE HARMFUL IF ABSORBED
THROUGH THE SKIN. CAN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: BE FATAL IF INHALED! CAN CAUSE
DELAYED LUNG INJURY. PRLNGD EXPOS MAY CAUSE
NAUSEA/HEADACHE/DIZZINESS AND/OR EYE DAMAGE. MAY BE FATAL IF
SWALLOWED! SUSPECTED CARCINOGEN-MAY PRODUCE CANCER. CH RONIC EXPOS
MAY CAUSE BRONCHITIS. CAN CAUSE DELAYED ADVERSE HEALTH EFTS.
INGESTION MAY CAUSE SEVERE CORROSION OF MOUTH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POISON.
IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE CAN BE
OBTAINED FROM POIS CTL CTR. EYES:FLUSH CONTINUOUSLY W/WATER FOR AT
LEAST 15-20 MIN. SKIN: FLUSH W/WATER FOR 15-20 MIN. IF NO BURNS
HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. INHAL: REMOVE TO
FRESH AIR. ADMIN OXYGEN IF HAVING DFCLTY BRTHG. IF BRTHG HAS
STOPPED (SUPDAT)

Fire Fighting

Flash Point:198F,92C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS IS A COMBUSTIBLE COMPOUND.

Accidental Release

Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP AND PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATE D SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES AND
CLOTHING. KEEP TIGHTLY CLOSED AND STORE IN A COOL, DRY PLACE. STORE
ONLY WITH COMPATIBLE CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HANDLE THIS CHEM OR ITS CNTNR. THIS PROD IS FURNISHED FOR LAB
USE ONLY! PRODS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRODS, FOOD ADDITIVES OR AS HOUSEHOLD
CHEMS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (SUPDAT)
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . USE
APPROPRIATE OSHA/MSHA APPROVED SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
LABORATORY.
Supplemental Safety and Health
FIRST AID PROC: ADMIN ARTF RESP. IF IN CARD ARREST ADMIN CPR. CONTINUE
LIFE SUPPORTING MEASURES UNTIL MED ASSISTANCE HAS ARRIVED. EYE
PROT: & FULL LENGTH FACESHIELD .

Chemical Properties

Boiling Pt:B.P. Text:401F,205C
Melt/Freeze Pt:M.P/F.P Text:3F,-16C
Spec Gravity:1.254
Solubility in Water:INSOL (IMMISCIBLE)
Appearance and Odor:COLORLESS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH STRONG OXIDIZING AGENTS. INCOMPATIBLE WITH IRON AND
ZINC AND OTHER LIGHT METALS.
Stability Condition to Avoid:DECOMPOSES UNDER ACIDIC CONDITIONS.
DECOMPOSED BY MOISTURE. AIR SENSITIVE.
Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES.
DECOMPOSITION PRODUCTS ARE CORROSIVE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . BURN IN A CHEMICAL INCINERATOR
EQUIPPED WITH AN AFTERBURNER AND SCRUBBER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.