CBJNM - 1104

Product Identification

Product ID:1104
MSDS Date:06/19/1991
FSC:6810
NIIN:00N068839
MSDS Number: CBJNM

Responsible Party
J & M LABORATORIES INC
1717 ROWAN
LOUISVILLE, KY 40203
US

Emergency Phone: 502-585-3176

Info Phone: 502-585-3176

Cage: GO699

Contractor
J AND M LABORATORIES, INC.
LOUISEVILLE, KY 40203 US

Telephone: 800-473-6173/502-585-3176

Cage: 01VT9

Ingredients

1) (SASA III) (CERCLA)

CAS: 7631-90-5

RTECS: VZ2000000

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


RECOVER AS MUCH OF PURE PRODUCT AS POSSIBLE

RTECS: 9999999ZZ


AVAILABLE ABSORBENTS MAY BE USED TO RECOVER ANY

RTECS: 9999999ZZ


CONTACT THE PERSONS RESPONSIBLE FOR THE OPERATION OF

RTECS: 9999999ZZ


INTENTIONALLY FLUSHING OR PUMPING SPILLS OR LEADS OF

RTECS: 9999999ZZ


UNDER THIS ACT. J & M LABORATORIES WILL

RTECS: 9999999ZZ


BEEN PLACED THEREIN, AND ASSUMING THE DRUM IS IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: WASH EXPOSED AREA W/PLENTY OF SOAP & WATER. REPEAT
WASHING. RINSE EXPOSED AREA FOR AT LEAST 15 MIN. CONSULT HLTH CARE
PROFESSIONAL. IF CLTHG COMES IN CONT W/PROD, IT SHOULD BE REMOVED
IMMED & LA UNDERED BEFORE REUSE. EYE: FLUSH IMMED W/COPIOUS AMTS OF
TAP WATER/NORM SALINE FOR AT LEAST 15 MIN. TAKE TO HLTH CARE
PROFESSIONAL. INHAL: IF PERS EXPERIENCES NAUS, HDCH/DIZZ, IMMED
MOVE TO (SUP DAT)

Fire Fighting

Flash Point:>212F,>100C
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:INITIALLY MIN AREA AFFECTED BY SPILL/LEAK.
BLOCK ANY POTENTIAL RTES TO WATER SYS. ASSESS IMPACT ON CONTAM
ENVIRON & MIN ANY ADVERSE EFTS. CONT YOUR MFR REPRESENTATIVE IMMED.
DETERMINE IF FED, STATE &/ LOC RELEASE NOTIFICATION IS REQUIRED.
(ING 2)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CLOSE CONTAINERS TIGHTLY WHEN NOT IN
USE.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED FILTRATION MASK MUST BE USED
IF THE TLV REDISUAL IS EXCEEDED.
Ventilation:GENERAL (MECHANICAL) ROOM VENTILATION IS EXPECTED TO BE
SATISFACTORY.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ACID RESISTANT APRON. EMERGENCY EYEWASH &
DELUGE SHOWER MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:DO NOT WEAR CONTACTS.
Supplemental Safety and Health
FIRST AID PROC: FRESH AIR. IF PERS HAS DFCLT BRTHG/IS CYANOTIC, ADMIN
OXYGEN IF AVAIL. CALL MD. INGEST: DO NOT INDUCE VOMIT. RINSE MOUTH
W/COPIOUS AMTS OF WATER/MILK FIRST. THEN SLOWLY DILUTE STOM CON
TENTS W/6-8 OZ OF WATER. IF PERS IS SEMICONSCIOUS,
COMATOSE/CONVULSING, DO NOT GIVE FLUIDS BY MOUTH. CONT MD IMMED.

Chemical Properties

Boiling Pt:B.P. Text:>302F,>150C
pH:3-5
Appearance and Odor:CLEAR, YELLOW LIQUID, WITH SULFUROUS ODOR

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZERS.
Stability Condition to Avoid:CONTAMINATION OF ANY KIND.
Hazardous Decomposition Products:OXIDES OF SULFUR AND SODIUM.

Disposal

Waste Disposal Methods:FOLLOW ALL FED, STATE, & LOC REGS GOVERNING DISP
OF WASTE MATLS. DETERMINE IF WASTE CONTAINING THIS PROD CAN BE
HANDLED BY AVAIL INDUS EFFLUENT SYS/OTHER ON-SITE WASTE MANAGEMENT.
SPILL/LEAK RESIDUALS MAY MEET CRITERIA OF CHARACT HAZ WASTE(ING 6)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.