CBLDM - S-780 FLOOR & WALL MORTAR/ALL COLORS, 58-00-9155

  • MSDS: CBLDM
  • Manufacturer: SUMMITVILLE LABORATORIES
  • Product Name: S-780 FLOOR & WALL MORTAR/ALL COLORS, 58-00-9155
  • National Stock Number: 5610-00N070104
Product Identification

Product ID:S-780 FLOOR & WALL MORTAR/ALL COLORS, 58-00-9155
MSDS Date:06/30/1994
FSC:5610
NIIN:00N070104
MSDS Number: CBLDM

Responsible Party
SUMMITVILLE LABORATORIES
MINERVA, OH 44657
US

Emergency Phone: 216-223-1511

Info Phone: 216-223-1511

Preparer: JAMES ANDERSON

Cage: SUMTV

Contractor
SUMMITVILLE LABORATORIES
MINERVA, OH 44657 US

Telephone: 216-868-6463

Cage: SUMTV

Ingredients

PORTLAND CEMENT

CAS: 65997-15-1

RTECS: VV8770000

Fraction By Weight: 30-50%

OSHA PEL 50 MPPCF

ACGIH TLV: 10 MG/M3 TDUST


SILICA, CRYSTALLINE - QUARTZ; (SILICON DIOXIDE)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 30-60%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:PORTLAND CEMENT MAY CAUSE EYE
AND SKIN IRRITATION. ACUTE OR RAPIDLY DEVELOPING SILICOSIS MAY
OCCUR IN A SHORT PERIOD OF TIME IN HEAVY EXPOSURE.
CHRONIC:PROLONGED EXPOSURE TO SILICON DIOXIDE DUST MAY CAUSE
DELAYED (CHRONIC) LUNG INJURY (SILICOSIS).
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GROUP 2A. NTP 7TH ANNUAL RPT
ON CARCINS. (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS, SENSITIVE
SKIN.

First Aid

First Aid:SKIN:WASH THORO W/SOAP & WATER. REMOVE CONTAM CLTHG IMMED &
WASH SKIN. IF IRRIT PERSISTS AFTER WASHING, GET MED ATTN. EYE:WASH
IMMED W/LG AMTS OF WATER FOR @ LST 15 MIN, LIFTING LIDS OCCAS. GET
MED AT TN IMMED. INHAL:REMOVE TO FRESH AIR IMMED, GET MED ATTN.
INGEST:IF PERSON IS CONSCIOUS, THEY SHOULD DRINK LG AMT OF WATER
IMMED. INDUCE VOMIT. DO NOT INDUCE VOMIT IN UNCON PERSON. GET MED
ATTN IMMED.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE.

Accidental Release

Spill Release Procedures:USE NORMAL CLEANUP PROCEDURES. AVOID DRY
SWEEPING AND WEAR PROTECTIVE EQUIPMENT. KEEP DUST TO MINIMUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID STORAGE IN CONDITIONS WHERE THE
PRODUCTS CAN BECOME WET.
Other Precautions:NOT APPLICABLE.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . IN COMPLIANCE WITH OSHA STANDARD 29 CFR
1910.134.
Ventilation:LOCAL EXHAUST, MECHANICAL (GENERAL):FOLLOW OSHA STANDARD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . AS REQUIRED TO MEET OSHA STANDARD.
Work Hygienic Practices:WASH HANDS THOROUGHLY BEFORE EATING OR SMOKING.
Supplemental Safety and Health
SOL IN H*2O:PORTLAND CEMENT PORTION REACTS WITH WATER. EXPLAN OF
CARCIN:1994:ANTICIPATED TO BE CARCINOGEN. ANIMAL:LUNG.

Chemical Properties

Spec Gravity:3.0 (H*2O=1)
Solubility in Water:SUPP DATA
Appearance and Odor:LIGHT GRAY TO WHITE POWDER, LITTLE OR NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:AVOID STORING MATERIALS IN HIGH HUMIDITY
FOR LONG PERIODS OF TIME OR WHERE THE BAGS CAN BECOME WET.
Hazardous Decomposition Products:NOT APPLICABLE.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE &
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.