CBMSN - ECI DOI WET LOOK ACRYLIC ENAMEL HARDENER, 102310

  • MSDS: CBMSN
  • Manufacturer: FIBRE GLASS EVERCOAT CO INC
  • Product Name: ECI DOI WET LOOK ACRYLIC ENAMEL HARDENER, 102310
  • National Stock Number: 8010-00N070865
Product Identification

Product ID:ECI DOI WET LOOK ACRYLIC ENAMEL HARDENER, 102310
MSDS Date:09/01/1994
FSC:8010
NIIN:00N070865
MSDS Number: CBMSN

Responsible Party
FIBRE GLASS-EVERCOAT CO INC
6600 CORNELL RD
CINCINNATI, OH 45242
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 513-489-7600

Cage: 18731

Contractor
FIBRE GLASS-EVERCOAT CO INC
CINCINNATI, OH 45242 US

Telephone: 513-489-7600

Cage: 18731

Ingredients

ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA) VP

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 22%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 200 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


HEXANE, 1,6-DIISOCYANATO-; (HEXAMETHYLENE DIISOCYANATE

CAS: 822-06-0

RTECS: MO1740000

Fraction By Weight: <1.5%

OSHA PEL N/K

ACGIH TLV: 0.005 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.

RTECS: 9999999ZZ


BELOW LOWER EXPLOSION LIMIT.

RTECS: 9999999ZZ


WET MATERIAL WITH SKIN. BARRIER CREAM MAY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CONTACT W/LIQ OR VAP MAY
RSLT IN IRRIT, REDNESS, TEARING & BLURRED VISION. SKIN: CNTCT W/WET
MATL MAY RSLT IN IRRIT, DERM & POSS SENSIT OF SKIN. INAHL: EXCESS
INHAL OF VAPS MAY CAUSE NASA L & RESP IRRIT, ACUTE NERVS SYS
DEPRESS, FATG, WEAK, NAUS, HDCH & DIZZ. MAY CAUSE ALLERGIC RESP RXN
IN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: SUSCEPTIBLE INDIVIDUALS. INGEST:
INGESTION OF MATL MAY CAUSE GI IRRIT, NAUS, DIARR & VOMIT. ASPIR OF
MATL INTO LUNGS DUE TO VOMIT MAY PRDCE CHEM PNEUM WHICH CAN BE
FATAL. CHRONIC: EXCESS OVE REXP TO SOLVS HAS BEEN ASSOC W/PERM
BRAIN & NERVS SYS DMG. PERSONS SENSITIVE TO ISOCYANATES WILL
EXPERIENCE (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH IMMED W/LARGE AMOUNTS OF WATER FOR AT LEAST 15
MIN. SEE MD FOR MEDICAL TREATMENT. SKIN: IMMED WASH AFFECTED AREA
W/SOAP & WATER. REMOVE CONTAMD CLTHG. CONSULT MD IF IRRITATION
DEVELOPS. IN HAL: REMOVE TO FRESH AIR. RESTORE BRTHG. KEEP PERSON
WARM & QUIET. TREAT SYMPTOMATICALLY. GET MED ATTN. INGEST: KEEP
PERSON WARM & QUIET. CONSULT MD OR POISON CONTROL CENTER IMMED.

Fire Fighting

Flash Point:98.0F,36.7C
Lower Limits:1.4%
Extinguishing Media:FOAM, CARBON DIOXIDE AND DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER, ALCOHOLS, AMINES & OTHER CMPDS REACT W/ISOCYANATES WHICH MAY
CAUSE PRESS BUILD-UP & POSS (SUPDAT)
Unusual Fire/Explosion Hazard:SOLV VAPS ARE HVR/AIR & MAY TRAVEL ALONG
FLOOR & BE IGNITED BY SPKS/FLAME AT DIST FROM WHERE MATL IS BEING
USED. POLYM OF MATL MAY OCCUR UNDER FIRE (SUDPAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENT AREA. WEAR
PROT EQUIP. AVOID BRTHG VAPS. CNTN SPILL. DEACTIVATE W/10% AMMONIUM
HYDROXIDE SOLN (HOUSEHOLD AMMONIA). AFTER 10 MIN, COLLECT OPEN
CNTNRS & ADD MORE AMMONI A. COVER LOOSELY. WASH SPILL AREA W/SOAP &
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE MATL IN COOL, WELL-VENTD AREA.
DO NOT STORE AT TEMPS ABOVE 75. DO NOT USE/STORE NEAR HEAT, SPKS OR
OPEN FLAME. KEEP CNTNRS TIGHT CLSD. (SUPDAT)
Other Precautions:THIS PROD MUST BE MIXED W/OTHER MATLS BEFORE USE. MIX
WILL HAV HAZ PROPERTIES OF ALL COMPONENTS. PLEASE REFER TO MSDS FOR
EACH COMPONENT PRIOR TO USE. IF PROD IS TO BE SPRAYED, APPROP
NIOSH/MSHA APPRV D RESP PROT IS REQD. KEEP OUT (ING 4)

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATORS DESIGNED TO
REMOVE MISTS & ORGANIC SOLVENT VAPORS. THIS PRODUCT SHOULD NOT BE
USED BY PERSONS WITH CHRONIC LUNG OR BREATHING PROBLEMS OR BY
INDIVIDUALS WHO HAVE HAD PREVIOUS REACTION TO ISOCYANATES.
Ventilation:GEN DILUTION OR LOC EXHST VENT SHOULD BE PROVIDED TO KEEP
EXPOS BELOW ACCEPTABLE LIMS & TO KEEP SOLV VAPS (ING 5)
Protective Gloves:NEOPRENE OR NATURAL RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
IMPERMEABLE CLTHG SHOULD BE WORN TO PVNT PRLNGD/RPTD CNTCT OF (ING
6)
Work Hygienic Practices:ALWAYS WASH HANDS AFTER USING THIS MATERIAL AND
BEFORE EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC: RUPTURE OF CNTNRS. EXPLO HAZ: CNDTNS. DECOMP PRODS,
GENERATED BY FIRE CNDTNS, MAY POSE HLTH RISK. POLYM OF MATL IN CLSD
CNTNR CAN CREATE PRESS BUILDUP WHICH MAY CAUSE RUPTURE OF CNTNR .
EFTS OF OVEREXP: INCREASED ALLERGIC RXN ON RPTD EXPOS. HNDLG/STOR
PRECS: AVOID CNTCT W/INCOMPAT MATLS.

Chemical Properties

Boiling Pt:B.P. Text:>255F,>124C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.069
Evaporation Rate & Reference:SLOWER THAN ETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:27

Stability

Stability Indicator/Materials to Avoid:YES
WATER, ALCOHOLS AND AMINES.
Stability Condition to Avoid:HIGH TEMPERATURES, IGNITION SOURCES AND
CONTACT WITH INCOMPATIBLE MATERIALS.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISP OF I/A/W FED, STATE & LOC REGS. WASTE FROM
PROD MAY BE HAZ AS DEFINED UNDER RCRA 40CFR261. WASTE MUST BE
TESTED FOR IGNIT TO DETERM APPLIC EPA HAZ WASTE NUMBERS. BEFORE
ATTEMPTING CLEAN-UP/DISP O F MATL, REFER TO HAZ INFO IN OTHER
MSDSSECTIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.